Leica LEICA DM4000 B fluorescence upright microscope LED fluorescence light source alternative solution - XLED-400 light source system
Date: 2025-05-27Read: 0

LeicaLEICA DM4000 BFluorescence upright microscopeLEDAlternative solutions for fluorescent light sources

——Innovate the bottleneck of traditional light sources and create a cost-effective fluorescent light source system




1、 LeicaDM4000 BApplication scenarios of upright microscope and pain points of light source aging

LeicaDM4000 BOrthostatic microscopes are widely used in clinical practice due to their high resolution and stabilityPathological diagnosis, industrial material analysis, immunofluorescence staining observationIt plays a core role in various fields, especially in high-frequency fluorescence staining sample observation (such as tumor marker detection, paraffin section analysis). However, it relies on traditional mercury lamps/Halogen lamp light sources are exposed to the following issues during long-term use:

  1. Short lifespan of light source:

    • Mercury lamp has a lifespan of only200The laboratory with high frequency of use requires monthly replacement of light bulbs, resulting in extremely high single cost.

    • The lifespan of halogen lamps is approximately500When the light intensity decreases rapidly, it affects the accuracy of fluorescence quantitative analysis.

  2. OEM parts dilemma:

    • Some Leica mercury lamp light sources have been discontinued (such asLEJ 100WMercury lamps rely on inventory or non-standard substitutes for procurement, and their reliability is questionable.

    • OEM (Original Equipment Manufacturer)LEDUpgrade plan (such asEL6000External cold light sources require specialized adapters, resulting in high overall renovation costs and extremely low cost-effectiveness for old equipment.

    • The ordering cycle for imported original accessories is long2-3Months, seriously affecting the daily operation of the laboratory

  3. Poor user experience:

    • Mercury lamp is required15Preheat for minutes, halogen lamp heats up severely, long-term use damages the sample.

  4. Optical path thermal damage:

    • mercury lamp/Halogen lamps generate a large amount of heat, and long-term use may accelerate the aging of the filter, further reducing the optical performance of the system.

      图片.png




2、 Wright OptoelectronicsXLED-400 LEDFluorescent light source solution: specifically designed for LeicaDM4000 Bdesign

Guangzhou Laite Optoelectronic Technology Co., LtdlaunchXLED-400microscopeLEDFluorescent light sourceOptimize the optical path characteristics of the upright microscope and achieve“Zero modification, low cost, high performance”Upgrade.

图片.png

Core advantages of the plan

  1. Ultra long lifespan and cost-effectiveness

    • LEDlifespan>20,000Hour, it's mercury lamp100Double,5No replacement required within the year.

    • cost comparison:

Light source type

Single cost

5Annual total cost (daily average usage)4Hour)

Original mercury lamp

¥8,000

¥80,000+(Replace)10Next time)

XLED-400

¥<2X,XXX

¥2X,XXX(No maintenance cost)

  1. Plug and play compatible design

    • adapter interface: Connect directly through Leica standard light source interface or fiber optic coupling adapterDM4000 BThe entrance of the optical path retains the compatibility between the original filter group and the objective lens.

    • Spectral coverage: Support5Channel independenceLED(such as365nmThe460nmThe530nmThe590nmThe630nm)Match commonly used dyes(DAPITheFITCTheCy3TheTRITCEtc.).

      图片.png

  1. Intelligent Control and Stability

    • Built in constant current driver chip, light intensity fluctuation<1%(Mercury lamp)10%)Ensure that the fluorescence quantification results are reproducible.

    • Support external trigger control to achieve microsecond level synchronization with camera exposure.

    • Built in efficient heat dissipation system to avoid the impact of traditional light sources“Thermal attenuation”effect




3、 Access plan and implementation process

1. Hardware composition

  • XLED-400hostCompact body, integrated with multiple wavelengthsLEDModule and air cooling system.

  • Coupling adapter componentIncludes Leica specific interfaces (including direct coupling and fiber optic coupling interfaces).

  • intelligent controllerUse a knob or touch screen to adjust the light intensity and channel switching.

2. Access steps(10Completed in minutes

  1. Turn off the microscope power and remove the original mercury lamp/Halogen lamp module.

  2. Translate into EnglishXLED-400Interface insertionDM4000 BLight source input port (original mercury lamp position), lock and fix the knob.

  3. Connect the host power supply to the controller, and preset it after booting up“Leica mode”Automatically match optical path parameters.

  4. Use calibration slides to verify the excitation uniformity of each channel and fine tune the coupling angle.

    图片.png




4、 User scenarios and value verification

Case: Pathology Department of a tertiary hospital

  • pain point: Daily processing200For example, fluorescent staining slices, frequent replacement of mercury lamps, and delayed reporting cycles.

  • Upgrade Effect:

    • 成本降低:5Annual savings and equipment maintenance costs¥50,000+.

    • Efficiency improvement: Removing preheating process, increasing daily sample processing volume30%.




5、 Service Guarantee and Action Guidelines

  1. Free trial: Provide7Trial use of the prototype, supporting comparison testing with the original light source on the same stage.

  2. Recycling of old equipmentMercury lamp/Halogen lamp light source can be deducted¥1,000-2,000Upgrade costs.

  3. Nationwide Warranty:1Annual warranty,48Hour by hour emergency response service.

Contact Wright sales personnel immediately to obtain LeicaDM4000 BdedicatedLEDFluorescent light source scheme


passXLED-ProSolution, LeicaDM4000 BUsers can break free from the constraints of traditional light sources and achieve a comprehensive upgrade of fluorescence imaging systems at a much lower cost than the original factory, empowering precise detection and efficient scientific research.