Installation and precautions of FA24 glass rotor flowmeter
Date: 2025-08-18Read: 14

When selecting the FA24 glass rotor flowmeter, many parameters are asked, including product parameters, environmental parameters, and so on. Whether the glass rotor flowmeter can be used properly depends not only on the selection, but also on the correct installation of the FA24 flowmeter. In order to ensure the normal operation and measurement accuracy of the FA24 glass rotor flowmeter, the following points should be noted when installing the FA24 glass rotor flowmeter:

636881886585720303786.jpg

1FA24 glass rotor flowmeterIt must be installed vertically on a vibration free pipeline. The fluid flows through the flowmeter from bottom to top, and the verticality is better than 2 °;
2. For the convenience of maintenance, replacement of flow meters, and cleaning of measurement pipelines, the FA24 glass rotor flow meter installed on the process pipeline should be equipped with bypass pipelines and bypass valves;
3. The inlet of the rotor flowmeter should have a straight pipe section of at least 5 times the diameter of the pipe, and the outlet should have a straight pipe section of 250mm;
4. If the medium contains ferromagnetic substances, a magnetic filter should be installed; If the medium contains solid impurities, it should be considered to install a filter between the valve and the straight pipe section;
5. When used for gas measurement, it should be ensured that the pipeline pressure is not less than 5 times the pressure loss of the flowmeter to ensure stable operation of the float;
6. In order to avoid deformation of the flow meter caused by the pipeline, the flange of the process pipeline must be coaxial and parallel to the flange of the flow meter. The pipeline support should be used to avoid pipeline vibration and reduce the axial load of the FA24 glass rotor flow meter. The control valve in the measurement system should be installed downstream of the flow meter;
7. When measuring gas, if the gas is directly discharged into the atmosphere at the outlet of the flowmeter, a valve should be installed at the outlet of the instrument, otherwise a pressure drop will occur at the float, causing data distortion.
Changzhou CityXinhua Instrument FactoryWith decades of production experience, we develop high-performance flow meters and directly supply various types of flow meters to manufacturers, providing customers with the right flow meters to choose from and answering various flow meter questions. For more issues with flow meters, please contact us