Detailed introduction of large capacity low-speed cryogenic centrifuge
Date: 2012-12-16Read: 0

1Low speed large capacity cryogenic centrifugeFeatures:

1. DC brushless motor, maintenance free, long service life.
2. Fully enclosed refrigeration compressor unit, with low noise and fast cooling speed.
3. Microcomputer temperature control and speed regulation system, LED digital display, easy to operate and convenient to use.
4. Equipped with unbalanced automatic shutdown function.
5. Centrifuge malfunction alarm prompt function.
6. Adopting a one-time molded 304 stainless steel inner liner, with a curved inner liner that transitions and is easy to clean inside the instrument.
IILow speed large capacity cryogenic centrifugeTechnical Specifications:
1. Temperature control range: -20 room temperature
2. Temperature control accuracy: ± 1 ℃
3. Temperature display resolution: 0.1 ℃
4. Speed range: 100-5000 revolutions per minute
5. Centrifugal tube capacity: 100ml x 4 or 50ml x 8 or 20ml x 16 or 10ml x 28 or 7ml x 36 (one set is standard when ordering, others need to be purchased)
6. Motor power: 750W
7. Cooling power: 380W
8. Timing range: 1-99 minutes
9. Power supply: 220V 50Hz
10. Dimensions: 450 × 530 × 750mm
11. Whole machine weight: 85kg
IIILow speed large capacity cryogenic centrifugeUsage:
1. When using, the appearance of the instrument should be checked for integrity, and the power cord should be undamaged.
2. Open the hood and take out the centrifuge tube. Place the substance to be separated into the centrifuge tube and weigh it together with the centrifuge tube to ensure that the weight inside each tube is equal, with a deviation of less than 2g. Then place the centrifuge tube onto the centrifuge tube rotor.
3. Connect the power supply and turn on the power switch. First, set the desired operating temperature, click the set button, and then use △ or ▽ to set the desired operating temperature. After setting, click the set button again to exit the setting state. At this time, the upper row displays the actual temperature inside the centrifuge chamber, and the lower row displays the temperature that needs to be operated. Refrigeration starts working. When the temperature reaches the set temperature, press the selection button to select the speed that needs to be separated. Press the selection button again, click △ or ▽ to select the time that needs to be separated. After setting is complete, click the approval button to confirm. Click the run button to start running. After running, there will be a buzzer prompt.
4. Open the hood, remove the centrifuge tube, and then turn off the power.
5. Clean the centrifuge properly to extend its service life.
4Low speed large capacity cryogenic centrifugePrecautions for use:
1. During each use, the centrifuge tube should be weighed together to ensure smooth operation.
2. Do not open the cover of the centrifuge during operation to avoid affecting the temperature control effect and safety of use.
3. Do not move the machine during the operation of the centrifuge.
4. The instrument adopts a 220V 50Hz power supply and should use a safety socket with safety grounding.