Safety precautions for drug packaging sterilizers
Date: 2025-08-27Read: 0
Drug packaging sterilizerIt is a specialized equipment used for sterilization treatment of medical devices, pharmaceutical packaging materials, etc.
Sterilization modes: rate rise and fall temperature (glass water resistance testing) mode, solid mode, instrument mode, liquid mode, liquid insulation mode, agar mode, solid drying mode, waste mode, required hardware to be purchased separately.
Safety protection: over temperature protection, over voltage protection, safety valve protection, dry burning protection of electric heating tubes, high and low water level monitoring, temperature safety lock, door closing monitoring, equipment error monitoring, full enclosure anti scald cover protection, power supply protection. Optional: Pressure safety lock, temperature and pressure alarm.
Voice prompt: The sterilization operation voice prompt function is more user-friendly.
Usage management: The system has a built-in security check and maintenance management program that automatically reminds users to perform security check and maintenance.
Water level monitoring: high and low water level monitoring, automatic water replenishment upon startup, and prevention of dry burning during operation.
Safety precautions:
Protective measures:
Wear heat-resistant gloves and goggles during operation, and do not forcefully open the door during operation.
The ethylene oxide sterilizer needs to be equipped with a dedicated exhaust system, and the concentration in the working area should be lower than the national safety standard.
Emergency response:
Immediately cut off the power supply when the pressure is abnormal, and trigger automatic pressure relief protection when the overpressure is 220 ± 5kPa.
When there is an odor or abnormal noise in the sterilizer, it should be stopped immediately and after-sales service should be contacted.
Maintenance requirements:
Disinfect the water storage tank weekly and regularly clean the condensate discharge outlet.
The sealing ring is replaced every 2 years, and the safety valve is calibrated annually.