Welcome Customer !

Membership

Help

Agilent Technologies (China) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Article

Agilent Technologies (China) Co., Ltd

  • E-mail

    inquire-china_lsca@agilent.com

  • Phone

  • Address

    No. 3 Wangjing North Road, Chaoyang District, Beijing

Contact Now
Double 11 Agilent Ultra High Inert Gas Chromatography Column Rapid Application Promotes Quality and Efficiency Improvement in Multiple Industries
Date: 2025-11-28Read: 0
双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效


双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

As a leading measurement company in the gas chromatography industry, Agilent is at the forefront of ensuring that the surfaces in contact with the samples remain inert, enabling you to achieve detection levels at ppb or ppt levels, meeting the most demanding analytical requirements.

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

Agilent J&W Ultra High Inert Gas Chromatography Column SeriesImproved industry standards in consistent column inertness and extremely low column loss, thusLower detection limits and more accurate analysis data can be obtained for complex analytes:

The advantage of ultra-high inertia


Trace detection of active compounds


Minimize peak tailing of active analytes to the greatest extent possible


No additional maintenance required, longer instrument operation time


Minimizing the loss or degradation of compounds to ensure more accurate quantitative analysis

Each J&W ultra-high inert gas chromatography column is tested using the industry's strictest mixed standards and comes with a performance summary table:

The powerful testing mixed standard can fully expose the defects of chromatographic column activity.The test mixed standard of Agilent ultra-high inert gas chromatography column has the characteristics of low molecular weight, low boiling point, and no steric hindrance active groups.These characteristics enable the detection points in the test molecules to penetrate and fully bind to the surface of the stationary phase and chromatographic column.

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

Pharmaceutical field

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

The production process of active pharmaceutical ingredients (APIs) may result in residual solvents in the finished product. For various reasons such as safety, impact on crystal structure, solubility, bioavailability, and stability, manufacturers need to monitor and control the concentration of residual solvents. There are many key factors in the analysis of solvent residues. In order to efficiently complete solvent residue analysis,Agilent has developed a rapid solution for solvent residue analysis.Shorten the GC running time to one-third of the original and complete the GC operation within 12 minutes. Greatly improve the operational efficiency of the instrument without affecting the chromatographic separation results.

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

food sector

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

Distilled liquor analysis: Agilent J&W DB-WAX UI gas chromatography column has stability and inertness

The Agilent J&W DB-WAX UI chromatographic column has a significant positive impact on the quantitative analysis of difficult to analyze volatile compounds in distilled spirits. The stability of DB-WAX UI stationary phase was highlighted through repeated injection of high moisture content samples. The retention time and peak shape of alcohols, aldehydes and organic acids were consistent during 200 times of direct injection of Baijiu.Ultra high inertia Wax colorSpectral columns exhibit excellent inertness and consistency in the analysis of distilled spirits.

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

Figure 1 Use Agilent J&W DB-WAX ultra high inert 30 m × 0.25 mm, 0.25 μ m gas chromatographic column (part number 122-7032UI) to analyze the GC/FID superposition chromatogram of repeated injection of the same Baijiu sample

Environmental field

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

Trace analysis of oxides in wastewater

It is necessary to monitor common trace levels of oxygen-containing industrial chemicals in wastewater or process water. DB-624UI exhibits excellent separation capability and peak efficiency, as shown in Figure 2. In this example, the sample was analyzed using headspace/GC/FID and Agilent J&W DB-624UI 60 m × 0.32 mm, 1.8 µ m chromatographic column. The concentration of the target analyte in water is 100 ppm (w/w).

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

Figure 2 Sharp chromatographic peaks of oxides in wastewater




Commonly used Agilent ultra-high inertia&

Performance and Application of Low Flow Loss Chromatography Column

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效




双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效
双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效
双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效


双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

Agilent 2025 Double 11

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效

During the Double 11 event

Gas column series

2 combinations59 fold

双 11 安捷伦超高惰性气相色谱柱快速应用助推多行业提质增效