verabar

NegotiableUpdate on 11/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Functional features: 1. Stable differential pressure signal, high measurement accuracy, anti blocking design; 2. Integrated dual chamber structure, high strength, suitable for high temperature and high pressure applications; 3. Widely applicable, suitable for various sizes of round and square pipes; 4. Low pressure loss, low energy consumption, and maintenance free; 5. New probe design and unique structure; 6. Can be equipped with temperature and pressure measurements for density compensation; 7. Small opening, easy installation, low requirement for straight pipe section, can be installed and maintained online under pressure

Product Details

Features:

1Stable differential pressure signal, high measurement accuracy, and anti blocking design;

2Integrated dual chamber structure, high strength, suitable for high temperature and high pressure applications;

3Widely applicable, suitable for various sizes of round and square pipes;

4Low pressure loss, low energy consumption, and maintenance free;

5The probe design is new and the structure is unique;

6Can be equipped with temperature and pressure measurements for density compensation;

7Small opening, easy installation, low requirements for straight pipe sections, and can be installed and maintained online under pressure.

Diameter range

50~2000mm

50~2000mm

12~50mm

Applicable Medium

Air, coal gas, flue gas, natural gas, tap water, boiler feedwater, and corrosive solutions; Saturated steam, superheated steam (with condenser), etc

Gas, liquid, steam

pressure range

Usually 0-25MPa, special 40MPa

Usually 0-16MPa, special 25MPa

Usually 0-10MPa

temperature range

Usually -50~450 ℃, special 700 ℃

Usually -50~450 ℃, special 550 ℃

Usually -50~300 ℃

turndown ratio

Greater than 10:1

Greater than 10:1

Greater than 5:1

Low flow velocity

Gas ≥ 4.5m/s, liquid ≥ 0.6m/s, steam ≥ 9m/s

Gas ≥ 10m/s, liquid ≥ 1m/s
Steam ≥ 12m/s

measurement accuracy

±1%

±1%

±1%

repetitiveness

±0.1%

±0.1%

±0.1%

mounting bracket
connection

Flange connection

Threaded rod connection

Use end flanges or threaded joints to connect with pipelines