Welcome Customer !

Membership

Help

Zhongke Weineng (Beijing) Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Zhongke Weineng (Beijing) Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No.1 Xinghua Street (Section 2), Daxing District, Beijing

Contact Now

fiber optic spectrometer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

CME-FS2000 is a lightweight miniature spectrometer that provides high-speed spectral acquisition and has * * * signal-to-noise ratio (SNR). Adopting CT type structural design, with a wavelength range of 200-1100nm, standardized SMA905 fiber interface, miniaturized volume, and stable structure. Widely used in various fields, such as transmittance and reflectance measurement, irradiance, absorbance and concentration measurement, color measurement, concentration measurement of chemical composition or radiometric analysis, film thickness measurement, gas composition analysis, protein, biological research and other fields.

Product Details

光纤光谱仪

Adopting imported high-performance grating/200-1100nm full spectrum/modularity/good thermal stability

CME-FS2000 is a lightweight miniature spectrometer that provides high-speed spectral acquisition and has a signal-to-noise ratio (SNR). Adopting CT type structural design, with a wavelength range of 200-1100nm, standardized SMA905 fiber interface, miniaturized volume, and stable structure. Support secondary development on Windows, Mac, and Linux platforms, and can be customized according to customers' requirements for optical resolution and luminous flux

Widely used in various fields, such as transmittance and reflectance measurement, irradiance, absorbance and concentration measurement, color measurement, concentration measurement of chemical composition or radiometric analysis, film thickness measurement, gas composition analysis, protein, biological research and other fields.

Product advantages:

1. The wavelength range can be selected from 200nm to 1100nm, and the slit can be selected from 5um-250um;

2. Adopting CT non cross symmetric optical path effectively reduces stray light and improves system resolution;

3. It can achieve a collection speed of 1ms;

4. Smaller and thinner size, more convenient to integrate into devices;

5. High anti reflective cylindrical mirror, stronger signal;

6. Rich optional accessories, including light source, fiber optic, and CCD probe;

7. No need for external power supply, USB direct power supply plug and play interface, stable operation;

8. Improve electronic design with 16 bit high-speed A/D conversion for fast data acquisition;

9. Integrate the GPIO interface of Zhongke Weineng, making it convenient for users to obtain data through USB, serial port, and SPI;

10. Provide a secondary development toolkit that encapsulates all functions, with one addition and multiple calls.


Technical parameters:


Model: CME-FS2000 (Basic Type) CME-FS2000H (High Sensitivity Type) CME-FS2000C (refrigeration type)
Wavelength range: 200nm-1100nm
Optical resolution: 1.33nm FWHM (typical value, dependent on wavelength range) 0.12nm FWHM (typical value, dependent on wavelength range) 0.41nm FWHM (typical value, dependent on wavelength range)
Wavelength resolution: 0.1nm (typical value, related to wavelength range) 0.07nm (typical value, related to wavelength range) 0.18nm (typical value, depending on wavelength range)
Linearity: >99%
Integral time: 1ms-65s 7.2ms~120s 7ms~15min
Dark noise: 50RMS Counts 20RMS Counts 9RMS Counts
Dynamic range: Spectrum: 1300:1; System: 8.5 * 10 ^ 7 15000:1 10000:1 @ 16 digits, 85000:1 @ 18 digits
Signal to Noise Ratio: 300:01:00 450:01:00 1000:01:00
Optical system: 75mm focal length, F/#:6, Symmetrical non intersecting CT optical path 100mm focal length, F/#:4.5, Symmetrical cross CT optical path 100mm focal length, F/#:4.5, Symmetrical cross CT optical path
Detector: Linear CCD Hamamatasu S10420 back illuminated CCD array Hamamatsu S7031
Incident slit (um): Standard 25 µ m can be selected from 5, 10, 50, 100, 200, 250
Grating: 600g/ mm@250nm 600 line @ 250nm 600 line @ 250nm
Pixel count: 2048 2048*64 1044 x 64 pixels
Eliminate high-order processing: Rear filter, used to eliminate ghost lines in the spectrum
A/D bits: 16 bits 16 bits 16 bit, 18 bit
Interface: USB、 Serial port SPI USB、 Serial port SPI USB、 Serial port SPI、 Ethernet port
External trigger: 4 trigger modes: Normal/Level/Edge/Synchronization
power waste: 250 mA @ 5 VDC
Size: 114mm*90mm*27mm 157mm*115mm*41mm 195mm*120mm*45mm
Weight: 0.4kg 0.8kg 1.2kg
Interface: SMA905