BIO II ADVANCE 6 PLUS Biosafety Cabinet, Level 2 Biosafety Cabinet Detailed Introduction:
1. Excellent and compact design
The laboratory space must be shared with an increasing number of devices. Moreover, it is often difficult to install safety cabinets on site. This is not only due to its size, but also because it is difficult to enter the laboratory. In view of this,telstarRedesignedbiosafety cabinetConcentrate all of its energy on minimizing the area of the cabinet where filters, fans, and electronic devices are located.
Therefore,BIO II Advance PlusImproved laminar flow efficiency helps to shorten the flow path of air inside the safety cabinet, making it a compact model on the market.
The benefits of microprocessor control include energy optimization, reduced heat dissipation, and significantly extended filter lifespan.
2. Provide a high degree of protection for operators, products, and the environment
biosafety cabinetThe most important feature is its containment capability, as well as good pollution prevention and containmentEasy to clean ability.Bio II Advance PlusThe series aims to always provide maximum safetySex:
•Laminar flow is monitored by a velocity sensor, which utilizes filter clogging compensation technologyTechnique to maintain a constant laminar flow throughout the entire workbench.
•The safety cabinet is equipped with an independent alarm system. Once any deviation occurs, the alarm system willSound and light alarms are triggered.
•At the working position, the gasket prevents environmental particles from entering the working chamber, thereby reducing the amount of sample that can be damagedBe able to pollute and keep the inside of the glass clean.
•The rounded edges inside the safety cabinet are convenient for disinfection and minimize contamination.
•The workbench is divided into several parts that can be cleaned or even sterilized in a high-pressure sterilizerBacteria.
3. Dual safety control panel with easy to read screen
BIO II Advance PlusThere is a color screen that allows for easy and quick viewing of safety parametersNumber. The display screen shows the degree of filter blockage, which is very useful for optimizing services. apparentThe display screen also shows laminar flow velocity for real-time control of the safety cabinet status.
4. Comfortable and easy to use
Bio II Advance PlusIntended to provide comfortable working conditions for operators by avoiding fatigue and encouraging safe working postures:
• Tilt10The front window of ° allows the operator to use ShuSuitable and ergonomic posture.
• Comfortable access to work through the front windowCreate a chamber that is easy to clean and can accommodate large objects and accessories in the workspace.
The monitor is slightly turned towards the operator to maximizeVisibility and accessibility.
Transparent glass side windows maximize accessThe lighting in the work chamber is used to increase visibility and provide a strong sense of space for the operator.
The front panel adopts a smooth integrated material design, which is easy to clean.
5. Reduce maintenance
The filter loading self compensation technology maintains a constant laminar flow velocity in the working chamber, thereby optimizing the service life of the filter and minimizing maintenance and upkeep.
All components are easily accessible through the front of the safety cabinet, thereby minimizing the time required to perform technical services. This minimizes the interruption of operators' daily work caused by preventive maintenance and re certification work to the greatest extent possible.
Electronic components can be in contact with the outside and separated from the contaminated area.
Filter replacement system,4FSystem: Fast(Fast), friendly(Friendly)And efficient(efficient)The system enables the filter to be easily replaced through the front safety cabinet, and using standard tools only requires a maximum cost5minute
6. Dual security, user-friendly and easy to read control panel
The display screen displays intuitive color codes and can instantly show the status of the safety cabinet:
Green screen: The safety cabinet is in a safe state
Red screen: Exceeding the specifications of the safety cabinet
Yellow screen: The safety cabinet is being purified
The main screen displays laminar flow velocity and filter blockage.
EcomodeThe function allows the safety cabinet to run at low speed with one click, allowing the operator to perform other tasks whileProtect the sample. This can save energy, reduce sound levels, and dissipate heat.
7. Other functions of the display screen:
• Continuous information about airflow status:
-Laminar flow velocity
-pumping speed
-Inflow velocity
• A timer for programming the daily activation of fans and UV lamps
Two password levels (user and technical service)
• Multilingual: Spanish, English, German, and French
Sound and light alarm with display information:
-Excessive or insufficient laminar flow velocity
-Insufficient exhaust rate
-Glass leaves the work position
-The front window is open
-UV lamp activation (interlocked with front off position)