Power quality refers to the quality of AC electricity supplied to users through the public power grid, and in layman's terms, it refers to the quality of electricity in the power grid lines. The power quality issues are mainly caused by the terminal load side. For example, impulsive reactive loads can cause severe voltage fluctuations in the power grid, reducing the quality of power supply.
With the development of power electronics technology, it has brought positive aspects of energy conservation and energy conversion to modern industry. At the same time, the widespread application of power electronic devices in various industries has also caused new and more serious damage to power quality, and has become the main source of harmonic pollution in the power grid.
The use of rectifiers, variable frequency speed regulation devices, electric arc furnaces, electrified railways, and various power electronic equipment in the distribution network of various user terminals in the power grid system is constantly increasing. Causing impact on the electricity network or electricity pollution. Causing voltage instability, overvoltage, harmonic generation, etc. Harmonics reduce the efficiency of the production, transmission, and utilization of electrical energy, causing electrical equipment to overheat, generate vibration and noise, and lead to insulation aging, shortened lifespan, and even failure or burnout. Harmonics can also cause local parallel resonance or series resonance in the power system, amplifying the harmonic content and causing equipment such as capacitors to burn out.
The nonlinear, impulsive, and unbalanced electrical characteristics of these loads cause serious pollution to the quality of power supply. Therefore, eliminating high-order harmonic problems in the power supply and distribution system has a very positive significance for improving power quality and ensuring the safe, stable, and economical operation of the power system.
On the other hand, modern industrial, commercial, and residential users' electrical equipment is more sensitive to power quality and has higher requirements for power supply quality. At present, harmonics, electromagnetic interference, and power factor reduction have been listed as the three major public hazards in the power system.
When the power quality of the power grid is disrupted or polluted, and cannot meet the relevant national standards, targeted improvement of the power quality of the power grid is necessary. To understand the actual situation of power quality in the power grid, it is necessary to have corresponding equipment for testing and analysis. Based on the actual situation in China, our company has timely developed professional power quality analysis instruments that are suitable for the national conditions. Below is a detailed explanation of the specific performance, parameters, and usage methods of the power quality analyzer.
Product Name: Electric Energy Meter Calibration Device, Electric Energy Meter On site Calibration Device, Three phase Electric Energy Meter On site Calibration Device, Electric Energy Performance Calibration Device, Three phase Electric Energy Meter Calibration Device
| Input characteristics | Voltage measurement range: 20V~200V~800V, automatic gear switching | |
| Current measurement range: clamp type transformers (three types): 5A/25A (standard); 100A/500A (optional); 400A/2000A (optional) | ||
| Phase angle measurement range: 0-359.99 ° | ||
| Frequency measurement range: 45-65Hz | ||
| Number of voltage channels: Three channels (UA, UB, UC) | ||
| Number of current channels: Three channels (IA, IB, IC) | ||
| Maximum harmonic analysis frequency: 63 times | ||
| Maximum continuous storage period with a 1-minute interval: 18 months | ||
| accuracy | Electrical parameter measurement section | Voltage: ± 0.2% |
| Frequency: ± 0.01Hz | ||
| Current and power: ± 0.5% | ||
| Phase: ± 0.2 ° | ||
| Power quality section | The allowable error of fundamental voltage is ≤ 0.5% F.S | |
| Allowable error of fundamental current: ≤ 1% F.S | ||
| Measurement error of phase difference between fundamental voltage and current: ≤ 0.2 ° | ||
| Measurement error of harmonic voltage content: ≤ 0.1% | ||
| Measurement error of harmonic current content: ≤ 0.2% | ||
| Three phase voltage imbalance error: ≤ 0.2% | ||
| Voltage deviation error: ≤ 0.2% | ||
| Voltage variation error: ≤ 0.2% | ||
| operation temperature | -10℃~ +40℃ | |
| Charging power supply | AC220V、 Frequency: 45Hz~55Hz | |
| Host power consumption | ≤3VA | |
| Maximum working time of battery | ≤ 10 hours | |
| isolation | The insulation resistance between the voltage and current input terminals and the casing is ≤ 100M Ω | |
| The working power input terminal is subjected to a power frequency of 1.5kV (effective value) between the shell and the working power input terminal, and the experiment lasts for 1 minute | ||
| volume | 320mm × 240mm × 130mm | |
| weight | 2.0kg | |
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. To learn more about Huatian products, please enter the product center. Service Hotline: 400-8855-448
Instrument host
Photoelectric sampler
Manual switch
Clamp type transformer (5A/25A)
Voltage testing line
Current testing line
Pulse meter test line
power line
232 communication line
Communication management software CD
10mm fish clip
4mm plug
Instruction manual, inspection certificate, certificate of conformity
complete set
host
Host screen
Host button area
Host socket
Attachment packing
Clamp type transformer clamp
Local photoelectric sampler
Our company's products are strictly produced in accordance with international and national standards and industry regulations. They have passed the testing of national, provincial, and municipal power research institutes, measurement centers, and authoritative power departments, and have fully passed the ISO9001 international quality management system certification, the People's Republic of China manufacturing measuring instrument license, GB/T19001-2016 quality management system requirements, GB/T24001-2016 environmental management system requirements, and GB/T45001-2020 occupational health and safety management system requirements.