[Scope of Application]:
A multi parameter measuring instrument used for high-precision laboratory measurements, covering various electrochemical parameters such as pH, conductivity, and dissolved oxygen. Suitable for industries such as petroleum, chemical, pharmaceutical, power plant, and environmental protection, it has a wider range of applications in education and scientific research.
:
7-inch color high-resolution (1024 * 600) capacitive touch screen, high sensitivity, complete parameter display, intuitive, easy to use, and simple to use.
Compliant with international GLP requirements, it has intelligent functions such as automatic calibration, automatic temperature compensation, data storage, USB output, clock display, wireless printing, function settings, and self diagnostic information.
The instrument is equipped with a bilingual operating system in both Chinese and English, with user-friendly operation design and adjustable brightness
The built-in large capacity storage can store 2000 sets of measurement data, which can be transferred through USB storage. The stored data can be opened with the universal office software EXELL, greatly facilitating customer editing.
The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation, and automatic pressure compensation.
The new structure of the polarographic dissolved oxygen electrode can simultaneously measure temperature, salinity, and dissolved oxygen. Equipped with a dedicated dissolved oxygen electrode calibration kit, electrode polarization only takes 3-5 minutes.
Using a combination diaphragm cap, when replacing the sensitive membrane, simply tighten the new diaphragm cap onto the electrode, making it extremely convenient to use.
Automatically recognize 8 types of conductivity standard solutions, with two series of standard solutions to choose from: European and American series and Chinese series.
Adopting advanced conductivity measurement technology, the conductivity electrode with a constant K=1 only requires one point calibration to meet the measurement accuracy requirements of 0.5 μ S/cm~200 mS/cm.
● switchable conductivity TDS、 Salinity and electrical resistivity. TDS and salinity are calculated using polynomials to ensure full range conversion accuracy.
Automatically identify pH standard buffer solutions, with three series of standard buffer solutions to choose from: European and American series, NIST series, and Chinese series.
The instrument comes standard with a Bluetooth module and supports wireless Bluetooth printing, making it convenient for users to operate. Optional support for wireless Bluetooth transmission of data to mobile phones and computers.
Designed to meet the IP54 dust and splash protection rating.
:
XSP335Precision pH/conductivity/dissolved oxygen three in one multi parameter analyzer
pH |
measuring range resolution accuracy Input Current Input impedance stability Temperature compensation range |
(-1.999 ~ 19.999)pH 0.1/0.01/0.001 pH Electricity meter:± 0.002 pH, matching: ± 0.01 pH ≤1×10-12A ≥3×1012Ω ±0.002 pH/3h hand movement/Automatic (-5.0~105.0) ℃ |
mV |
measuring range(mV/ORP/EH) resolution accuracy |
-1999.9mV ~ 0 ~ 1999.9mV 0.1mV ±0.03% FS |
conductivity |
measuring range
resolution accuracy Temperature compensation range Electrode constant Reference Temperature |
Conductivity:(0.00~20.00)μS/cm (20.0~200.0)μS/cm (200~2000)μS/cm (2.00~20.00)mS/cm (20.0~200.0)mS/cm (200~2000)mS/cm(K=10) Electrical resistivity:(0 ~ 100)MΩ·cm TDS: (0 ~ 100)g/L Salinity:(0 ~ 100)ppt 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm Electricity meter:± 0.5% FS, matching: ± 0.80% FS (0~50 ℃ (automatic) 0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1 25 ℃, 20 ℃, and 18 ℃ |
dissolved oxygen |
measuring range resolution accuracy response time Residual current Temperature compensation range Salinity compensation range Pressure compensation range Automatic calibration electrode type |
(0 ~ 20.00)mg/L(ppm) (0 ~ 200.0)% 0.1/0.01 mg/L(ppm) 1/0.1 % Electricity meter:± 0.10 mg/L, matching: ± 0.40 mg/L ≤ 30 seconds (25 ℃, 90% response) ≤0.1 mg/L (0~45 ℃ (automatic) (0~45) PPT (automatic) (80~105) kPa (automatic) Air saturated with water; Water saturated with air Polarographic formula |
temperature |
measuring range resolution accuracy |
-10℃~ 110℃ 0.1℃ 5~60 ℃ range: ± 0.4 ℃ Other ranges: ± 0.8 ℃ |
Other technical parameters |
Storage Storage Content power supply communication interface Size and Weight |
2000group Measurement value number, measurement value, temperature valueATC or MTC status, measurement date, measurement time DC9V/300mA RS232、USB2.0、 Wireless Bluetooth interface 160 × 190 × 70mm/880g |
working conditions |
ambient temperature ambient humidity IP GRADE |
5~35 ℃ (0.01 level) 15~30 ℃ (0.001 level) ≤75% IP54 dustproof and splash proof |
Dissolved oxygen is determined by polarographic method. Customers should prepare their own magnetic stirrer or choose our factoryR100 magnetic stirrer
1. One pH/mV/conductivity/dissolved oxygen measuring instrument host
2. One universal electrode holder
3. One 201T-M plastic shell pH/ATC triple composite electrode
4. One 2503-C glass pH composite electrode
5. MP500 temperature electrode 1 piece
6. One 2401-M conductive electrode
7. One DO500 dissolved oxygen electrode
8. One bottle of pH standard buffer solution (pH4.00, pH6.86, pH9.18/50ml) each
2 bottles of 1408 μ S/cm conductivity standard solution (50ml)
10. One 9V power adapter (for instrument use)
11. DO503 diaphragm cap (for dissolved oxygen electrode) 3 pieces
12. DO502 dissolved oxygen electrode solution (30ml) 1 bottle
13. Two sheets of cathode polishing paper
14. One copy of the instruction manual