This controller is professionally designed for the solar energy industry and can monitor simultaneously
The display range for the solar outlet water temperature PV1 and the temperature PV2 of the thermal storage water tank is
-From 199.9 ℃ to 600.0 ℃, when the temperature difference between PV1 and PV2 increases, it can
Activate the solar circulation pump (optional); When the temperature difference between PV1 and PV2 shrinks
Hour, can automatically stop the solar circulation pump (adjustable) to achieve heating
Quantity conversion and storage to enhance the efficiency of solar energy utilization.
1. Working power supply: AC/DC85-260V (other power supplies can be customized)
2. Power consumption: less than 5W
3. Input signal: Pt100
4. Display mode:
Pv1: Display solar outlet temperature
Pv2: Display the temperature of the thermal storage water tank
5. Display range: -1999.9 to 600.0
6. Temperature difference range: 0-200 ℃
7. Accuracy: 0.2% FS ± 1 word
8. Contact capacity: AC250V/3A
DC24V/5A
9. Operating environment: 0-50 ℃; ≤85%RH