Convenient operationThe YST108B-NTU680T device supports touch screen operation, with a built-in simplified menu that allows basic settings to be completed without the need for professional technicians; Some models are equipped with automatic cleaning function to reduce the frequency of manual maintenance.
Real time data processingIt can achieve 24-hour continuous monitoring, with a data update interval of up to 1 second, and can quickly capture sudden changes in turbidity (such as water inflow impact in sewage treatment plants, pipe network leaks, etc.).
Wide adaptability to various scenariosThe body protection level can reach IP65/IP68, which can adapt to complex environments such as outdoor, humid, and high temperature. It can be used for fixed monitoring in laboratories, as well as deployed in outdoor rivers and pipeline stations.
Easy data transmissionSupports multiple data transmission methods such as RS485, Ethernet, 4G/5G, etc., and can directly interface with water plant SCADA systems and environmental monitoring platforms to achieve remote data viewing and storage.
parameter category |
Common specification range |
measurement range |
0.01~1000 NTU; 0~4000 NTU (optional) |
power supply method |
AC 220V±10%; DC 12V~24V |
output signal |
4-20mA analog signal; RS485 digital signal |
Operating Temperature |
-10℃~50℃ |
Operating Humidity |
≤ 90% RH (non condensing) |
Installation method |
Pipeline type, submerged type, flow pool type (optional) |
calibration method |
Manual calibration; Automatic calibration (optional) |
Match monitoring rangeSelect the range configuration of YST108B-NTU680T equipment based on the characteristics of industry water quality. For example, low range (0.01~100 NTU) is preferred for water treatment plants and water purification plants, while high range (0~4000 NTU) is required for sewage treatment plants and river monitoring.
Adapt to installation scenariosPipeline installation configuration for water transportation (such as municipal pipeline network and thermal heating water); Open water bodies (rivers, reservoirs) should be configured in a submerged manner; Choose a flow pool configuration for laboratories or small sites.
Pay attention to data requirementsWhen remote monitoring or platform docking is required, priority should be given to configurations that support wireless transmission (4G/5G); If viewed only locally, the basic model (RS485+analog output) can meet the requirements.
Consider environmental adaptabilityOutdoor or humid environments (such as chemical wastewater workshops and riverbanks) require a high protection level (IP67 or above) configuration; In low-temperature areas, it is necessary to confirm whether the equipment supports low-temperature startup configuration.
sewage treatment plantMonitor the inlet turbidity (to determine sewage load), aeration tank turbidity (to adjust aeration rate), and outlet turbidity (to ensure standard discharge) using YST108B-NTU680T equipment.
Water treatment plant/water purification plantReal time monitoring of raw water turbidity (warning of pollution), sedimentation tank effluent turbidity (optimizing flocculant dosage), and factory water turbidity (ensuring residential water safety).
Municipal water supply networkDeploy YST108B-NTU680T pipeline equipment at intermediate or terminal stations in the pipeline network to monitor changes in turbidity and assist in determining whether there are leaks or secondary pollution in the pipeline network.
Environmentally Friendly Water TreatmentUsed for centralized sewage treatment stations in industrial parks to monitor turbidity before and after treatment, providing data basis for environmental protection department supervision.
Thermal heatingMonitor the turbidity of heating circulating water to avoid suspended particles in the water blocking the pipeline and affecting heat transfer efficiency.
Hospital wastewater treatmentMonitor the turbidity of disinfected wastewater to ensure that medical wastewater meets discharge standards after treatment and to prevent the spread of bacteria with suspended solids.
Chemical wastewater treatmentReal time monitoring of turbidity in pre-treatment processes (such as sedimentation and filtration) for high turbidity and high pollution chemical wastewater, optimizing treatment processes.
River water quality monitoring: Lay YST108B-NTU680T immersed equipment in rivers and lakes to track turbidity changes for a long time and warn of water quality deterioration caused by rainstorm scouring and sewage discharge.
Smart rural water managementUsed for rural centralized water supply stations to monitor the turbidity of well water and reservoirs, providing basic water quality assurance for rural residents.
intelligent upgradeAI algorithms will be integrated to automatically identify abnormal data (such as sudden increases in turbidity) and trigger warnings, while combining historical data to predict water quality trends.
Multi parameter integrationUpgrade from single turbidity monitoring to multi parameter integration such as turbidity+pH+dissolved oxygen+residual chlorine, reducing equipment deployment and lowering operation and maintenance costs.
Low power consumption and portabilityDevelop a low-power, solar powered portable configuration for outdoor scenarios without power supply (such as remote rivers) to meet the needs of temporary monitoring or mobile inspection.
operation automationPopularize automatic calibration and cleaning functions, and some configurations will provide reminders for the remaining amount of consumables (such as cleaning solution), further reducing manual intervention.
Sewage treatment plant operation and maintenance personnelYour YST108B-NTU 680T equipment has a very practical continuous monitoring function. Previously, it relied on manual sampling and detection, often missing the peak turbidity of the incoming water. Now it can adjust the process in real time, and the effluent compliance rate is much more stable. ”
Technical Supervisor of Water PlantThe YST108B-NTU680T device seamlessly integrates with our SCADA system, with real-time upload of turbidity data from the factory water, eliminating the need for manual recording, saving time and avoiding data errors. ”
River monitoring personnelThe protection of the YST108B-NTU680T outdoor model is well done, and it can work stably even in rainy and hot days. Remote data viewing does not require frequent on-site visits, and efficiency has been greatly improved. ”
Rural Water AdministratorThe YST108B-NTU680T equipment is easy to operate, and the village maintenance personnel can learn it in half an hour without hiring professional personnel, reducing our maintenance pressure. ”
Application scenariosThe processing capacity is 100000 tons/day, and it is necessary to monitor the turbidity of three key nodes: inlet, aeration tank, and outlet. Three YST108B-NTU680T devices (high range configuration) are selected.
Monitoring requirementsReal time capture of sudden changes in influent turbidity (such as rainwater mixed in during the rainy season) to avoid process overload; Ensure that the turbidity at the outlet meets local emission standards.
Usage effectThe equipment transmits real-time data to the central control room, and automatically alarms when the inlet turbidity exceeds the threshold. The operation and maintenance team can adjust the process within 10 minutes; The turbidity data at the outlet has remained stable and met the standard for six consecutive months without any excessive emissions.
Application scenariosDeploy YST108B-NTU680T pipeline equipment at 12 key nodes of the urban water supply network, such as the entrance of residential areas and the end of the network.
Monitoring requirementsCheck for leaks in the pipeline network (sudden increase in turbidity may indicate external water infiltration) and monitor secondary water supply pollution.
Usage effectBy analyzing the turbidity data transmitted by the equipment, two leakage points in the pipeline network were successfully located and repaired in advance to avoid water resource waste; Discovered abnormal turbidity in the secondary water supply tank of one residential area, promptly urged cleaning, and ensured the safety of residents' water use.
Application scenariosInstall YST108B-NTU680T submersible equipment in 5 monitoring sections of urban inland rivers, in conjunction with dissolved oxygen and pH monitoring equipment.
Monitoring requirements: Track the effect of river regulation (such as turbidity change after dredging and sewage interception), and warn the surrounding enterprises of pollution caused by illegal drainage and rainstorm scouring.
Usage effectDuring the treatment period, the turbidity of the river decreased from an average of 80 NTU to 25 NTU, and the data can visually demonstrate the effectiveness of the treatment; After a rainstorm, the turbidity rises sharply. Through data analysis, the upstream inlet scouring problem is locked, and the closure measures are taken in time.