feature
-Adopting fuzzy logic PID control and high-precision PT1000 temperature sensor to achieve a control accuracy of 0.1 degrees, the temperature control is precise and realistic.
-It has an automatic zero calibration function, which can automatically perform an automatic zero adjustment once during initial installation or shutdown and restart, ensuring that the CO2 concentration does not produce positive or negative drift.
-The fully curved inner box structure is electrolytic polished to reduce the area of microbial contamination, making it easy to clean and disinfect.
-Equipped with pressure compensation holes to avoid abnormal pressure during intake and prevent the absorption of ambient air when opening the door.
-The all-round three-dimensional heating method and unique air duct structure ensure the uniformity of CO2 concentration and temperature inside the box.
-The box door has an independent heating function to prevent condensation on the glass door. The chassis heater controlled by a microcomputer is independent of the heater and automatically starts when the door is opened. The humidity inside the box quickly returns to the range of 93% to 98%.
-Equipped with intelligent alarm function, temperature deviation alarm, CO2 concentration deviation alarm, etc.
-Configure an over temperature protection system to ensure the safety of the product, and equip it with a leakage protector for safer and more user-friendly use.
-All air intakes are equipped with microbial filters to minimize contamination inside the box.
-Dual temperature probes ensure more accurate temperature measurement inside the incubator.
application

Cell Biology

basic research

biopharmaceutical

IL-185VT

IVF
Numerous advantages ensure the safe and reliable growth of cells

Each IL-185 series carbon dioxide tank is equipped with a HEPA high-efficiency filter to eliminate pollution

After the box door is closed, the gas purification inside the chamber reaches level 100 within 5 minutes.

The design of the heated glass inner door prevents microbial contamination caused by condensed water.
![]() |
||||
| High precision gas sensors, VAISALA dual beam infrared (IR) sensors are recommended for use in situations where temperature and humidity fluctuate frequently. | The inner liner is electrolytic polished, with smooth rounded inner walls, reducing unnecessary inner surface area and thus reducing the probability of bacterial contamination, making it easy to quickly and effectively clean the inner walls. | The reliable latch design of the inner glass door ensures carbon dioxide sealing and cell culture conditions. | ||
|
Product Type |
Water jacket carbon dioxide tank |
|
|
model |
IL-185VT |
IL-185-VI |
|
effective volume |
185 |
|
|
Temperature control range |
Room temperature+5-55 ℃ |
|
|
temperature sensor |
PT1000 |
|
|
Temperature control accuracy |
±0.1℃ |
|
|
Temperature control alarm |
≥ ± 0.1 ℃ (adjustable) |
|
|
CO2 control range |
0~20% |
|
|
CO2 control accuracy |
At 5%, ± 0.1% |
|
|
CO2 sensor |
TCD |
IR |
|
CO2 alarm |
≥ ± 0.1% (adjustable) |
|
|
CO2 inlet filtration efficiency |
99.998% |
|
|
CO2 door opening recovery time |
About 1%/min |
|
|
Internal humidification water tray |
3 liters |
|
|
relative humidity |
95±3% |
|
|
Dimensions (W * D * H) |
660*630*1105 |
|
|
Internal cavity size (W * D * H) |
540*505*680 |
|
|
Inner liner structure |
Full arc |
|
|
Stainless steel partition |
4 pieces |
|
|
power supply |
220V 50HZ/60HZ |
|
|
Sterilization method |
none |
|
|
Factory standard plug |
10A |
|
|
HEPA filtration |
have |
|