◆ Purpose and Characteristics
Compact structure, low height, good anti eccentric load performance, suitable for measuring bolt prestress and clamping force
◆ Technical parameters
Range: 0-0.05-500KN
Comprehensive accuracy: ± 0.5% FS
Output: 1-2.0mV/V, 4-20mA/0-5/0-10V
Zero point output: ± 1% F • S
Zero temperature influence: ± 0.1% F • S/10 ℃
Output temperature influence: ± 0.1% F • S/10 ℃
Working temperature: -10 ℃~+70 ℃
Compensation temperature range: -10 ℃ to+65 ℃
Input impedance: 385 ± 30 Ω
Output impedance: 350 ± 4 Ω, 700 ± 4 Ω
Insulation resistance:>2000M Ω (50VDC)
Safe overload: 150% F • S
Supply bridge voltage: recommended 10VDC
Material: stainless steel, alloy steel
Wiring Method: Power Supply (+) Red Line Power Supply (-) Green Line Output (+) Yellow Line Output (-) White Line
Structural dimensions: The basic dimensions are shown in the diagram below, and specific dimensions can be customized according to customer requirements.
◆ Product outline drawing(Unit: mm)