WRN208 temperature sensor

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product applications are usually used in conjunction with display instruments, recording instruments, electronic computers, etc

Product Details

Product Application
Usually used in conjunction with display instruments, recording instruments, electronic computers, etc. Directly measure the temperature of liquid, vapor, gas media, and solid surfaces within the range of 0 ℃ to 1300 ℃ in various production processes.
Product Features
Less thermal response time, reducing dynamic errors; Flexible installation and use; Large measurement range; High mechanical strength and good pressure resistance.
Product execution standards
IEC584 IEC1515 GB/T16839-1997 JB/T5582-91

working principle:

The electrodes of armored thermocouples are composed of two conductors of different materials. When there is a temperature difference between the measuring end and the reference end, a thermoelectric potential is generated, and the working instrument displays the temperature value corresponding to the thermoelectric potential.

Measurement range and tolerance (tTo measure the actual temperature value)

model

Graduation

Tolerance levelⅠ

Tolerance levelⅡ

Allowable deviation

Measuring range℃

Allowable deviation

Measuring range℃

WRNK

K

±1.5℃

-40~+375

±2.5℃

-40~+333

0.004│t│

375~1000

±0.0075│t│

333~1200

WRMK

N

±1.5℃

-40~+375

±2.5℃

-40~+333

±0.004│t│

375~1000

±0.0075│t│

333~1200

WREK

E

±1.5℃

-40~+375

±1.5℃

-40~+333

±0.004│t│

375~800

±0.004│t│

333~900

WRFK

J

±1.5℃

-40~+375

±1.5℃

-40~+333

±0.004│t│

375~750

±0.004│t│

333~750

WRCK

T

±1.5℃

-40~+125

±1.5℃

-40~+133

±0.004│t│

125~350

±0.004│t│

133~1000

WRPK

S

±1℃

0~1100

±2.5℃

0~600

1100~1600

±0.0025│t│

600~1600

Room temperature insulation resistance armored thermocouple operates at an ambient temperature of20±1.5℃, relative humidity not exceeding80%The test voltage is500±50VInsulation resistance between (DC) electrode and outer sheath≥1000MΩ.m.
approach1mLong specimen,Its insulation resistance is1000MΩ;10mLong specimen,Its insulation resistance is100MΩ.

Wire diameter and material

Even wire diameter

Single branch type

Double branch type

Casing diameter

Φ2,Φ3, Φ4, Φ5, Φ6, Φ8

Φ3, Φ4, Φ5, Φ6, Φ8

Material of casing

E、J、T

1Cr18Ni9Ti

1Cr18Ni9Ti

K、N

1Cr18Ni9Ti GH3030

1Cr18Ni9Ti GH3030

S

GH3030

GH3030

thermal response time

Pipe sleeve diameter

Φ3

Φ4

Φ5

Φ6

Φ7

other

Thermal response time(S)

≤3

≤4

≤8

≤12

≤15

Additional device form