WIC-II ion chromatograph

NegotiableUpdate on 03/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The WIC-2 ion chromatograph applies the principle of ion exchange chromatography to quickly separate various ions in a separation column. The strong electrolyte in the eluent is removed by a suppressor to deduct the background conductivity. Then, the conductivity values of the effluent are continuously measured by a five electrode conductivity detector to obtain chromatographic peaks of various ions. Multiple ions can be detected simultaneously with one injection, and separation, qualitative and quantitative analysis can be completed in one go. According to user needs, a recorder (or chromatography workstation) can be configured. Technical specifications: * Infusion pump: Flow range: 0.02~10mL/min Discharge range: 0~250 kg/cm2 Flow stability: 1% Pressure fluctuation: 1% * Anion: Detection of F -, Cl -, NO2-, PO43-, Br -, NO3-, SO42- in 16 minutes Detection lower limit: better than 5g/L (calculated as non concentrated Cl -) Reproducibility: better than 3% (calculated as SO42-) Linear range:>102 * Cation: Detection of L1+, Na+, NH4+, K+in 16 minutes Detection of Mg2+, Ca2+in 12 minutes Characteristics: * High sensitivity * Good selectivity * High accuracy * Reliable results * Fast analysis speed * Suppressor does not require periodic regeneration and can be used continuously. Environmental monitoring, teaching, chemical engineering, metallurgy
Product Details


The WIC-2 ion chromatograph applies the principle of ion exchange chromatography to quickly separate various ions in a separation column. The strong electrolyte in the eluent is removed by a suppressor to deduct the background conductivity. Then, the conductivity values of the effluent are continuously measured by a five electrode conductivity detector to obtain chromatographic peaks of various ions. Multiple ions can be detected simultaneously with one injection, and separation, qualitative and quantitative analysis can be completed in one go. According to user needs, a recorder (or chromatography workstation) can be configured.

Technical indicators:
*Infusion pump: flow range: 0.02~10mL/min
Pressure range: 0-250 kg/cm2
Flow stability: ± 1%
Pressure fluctuation: ± 1%
*Anion: 16 minute detection of F-、 Cl-、 NO2-、 PO43-、 Br-
NO3-、 SO42-
Detection limit: better than 5 μ g/L (without concentrated Cl)-Calculation)
Reproducibility: better than 3% (based on SO)42--Calculation)
Linear range:>102
*Cation: 16 minute detection time L1+、 Na+、 NH4+、 K+
12 minute detection of Mg2+、 Ca2+

characteristic:
*High sensitivity
*Good selectivity
*High accuracy
*Reliable results
*Fast analysis speed
*Suppressors do not require periodic regeneration and can be used continuously

Applied to environmental monitoring, teaching, chemical engineering, metallurgy