E-mail
13810457507@139.com
-
Phone
13810457507
-
Address
A302 Huiyuan Building, No. 5 Zaojunmiao Road, Haidian District, Beijing
Beijing Jingkeshuo Technology Co., Ltd
13810457507@139.com
13810457507
A302 Huiyuan Building, No. 5 Zaojunmiao Road, Haidian District, Beijing
¥Veterinary drug residue detectorProduct Overview
National food safety testing standards, based on competitive enzyme-linked immunosorbent assay, quantitatively detect veterinary drug residues in livestock and poultry meat products such as pig, chicken, and duck milk,
Testing standard: GB 31650-2019 National Food Safety Kit: Lean Meat Powder Triple Elisa Kit, Clenbuterol Hydrochloride, Lectopamine. Professional pre-treatment equipment for slaughterhouses includes pipettes, centrifuges, incubators, and 96 channels
▼Veterinary drug residue detectorFeatures
※ 7.1-inch high-resolution color touch screen, easy to operate, no need for additional computer ※ Endpoint method, dynamics, universal mode, single/dual wavelength measurement ※ Fast detection speed, rich software configuration, can be used alone or connected to a computer ※ When the instrument is started, the system will automatically calibrate the position of the carrier board, light source, and filter ※ With clock function, the visual layout can be stored, and the detection command function can be called ※ The data management function has a large storage space, and data can be exported and stored at any time ※ Veterinary drug residue test kit and portable detection box are optional
1. Light source: halogen lamp, automatic control, with a lifespan of up to 4000h
2. Optical path system: 12 detection channels, 1 reference channel
3. Detector: Imported silicon photodiode
4. Wavelength range: 400-800nm
5. Filter: Standard configuration includes 405, 450, 492, and 630nm, while other wavelengths are optional
6. Reading range: 0-4.000Abs (450nm)
7. Linear range: 0-3.000Abs (450nm)
8. Filter bandwidth: 8nm
9. Resolution: 0.001Abs
10. Accuracy (405nm): ± 1% (0-3Abs), ± 2% (3-4Abs)
11. Accuracy (405nm): CV ≤ 0.2% (0-3Abs), CV ≤ 1% (3-4Abs), standard measurement mode
12. Indication error: ≤± 0.01Abs
13. Stability: ≤± 0.003Abs
14. Repeatability: ≤ 0.3%
15. Vibration board function: Three adjustable speeds: high speed, medium speed, and low speed, with adjustable time from 0-999 seconds
16. Display operation: 7.1Inch touch screen input and display of whole board information
17. Reading speed: single wavelength3second/96 holes, dual wavelength 6 seconds/96 holes
18Workstation: Computer based enzyme-linked immunosorbent assay (ELISA) analysis software, equipped with comprehensive functions such as project detection, data processing, curve fitting, and data management.
19Endpoint method, two-point method, dynamics, single/dual wavelength testing modes, etc
20Data output: COM+USB (communication, printer, USB drive)
21Printer: Optional thermal printer
23Power supply: wide voltage design AC100-240V 50Hz.
24Net weight: approximately 11.5Kg
25.ruler Inch:420mm(L)*320mm(W)*160mm(H)