Welcome Customer !

Membership

Help

Beijing Relying on Huamao Biotechnology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Relying on Huamao Biotechnology Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 3018, Zhengze Business, No.2 Qingnian Road, Beijing

Contact Now

Ultra pure water system, U series

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

This 2-in-1 laboratory ultrapure water system, the U series, is capable of producing Type I ultrapure water and Type III RO water from tap water. The quality of ultrapure water meets or exceeds the standards of ASTM, CLSI, CAP, and ISO Type I water

Product Details

This 2-in-1 laboratoryUltra pure water system, U seriesCapable of producing Type I ultrapure water and Type III RO water from tap water. The quality of ultrapure water meets or exceeds the standards of ASTM, CLSI, CAP, and ISO Type I water

  • Simple and intuitive way to fetch water through the water handle or center console
  • The center console is an 8-inch waterproof touch screen, and users can control the pure water system through the center console.
  • A single pure water host can be equipped with multiple water intake handles ("1+N mode")
  • The water outlet speed of the handle can reach up to 2L/minute, and it can also take water quantitatively
  • Consumables with RFID tags can track the production date, installation date, replacement period, excess water volume, and usage time throughout the entire process
  • Both the controller and the center console can be wirelessly controlled (optional)
  • Real time TOC and resistivity/conductivity monitoring
  • Optional water tank circulation upgrade component to maintain stable water quality in the tank
  • Users can view basic information (water quality, system status, warning messages) at any time on the water intake handle and center console, with data storage up to 2 years and downloadable

The graphical interface of the monitor can guide users in system operations, troubleshooting, and maintenance work, and multiple permission levels can be set through passwords

Application scope (Type I ultrapure water): HPLC mobile phase preparation; Preparation of reagent blank solution; Dilute samples using GC, HPLC, ICP-MS, AA, and other analytical techniques; Preparation of buffer and culture medium for mammalian cell culture; Preparation of molecular biology reagents.

Application scope (Type III RO water): Cleaning of glassware; Machine for cleaning glassware; Water for water bath and high-pressure sterilizer; Laboratory animal water.

Certifications:The VWR pure water system comes with a certificate of conformity to ensure that the product has been fully manufactured and tested according to standard operating procedures, and provides calibration certificates for the temperature and resistivity meters built into the system. Consumables will provide quality certificates along with the goods. The production factory has obtained ISO 9001 (2015) and ISO 140001 certifications.

Ordering NoticeA complete pure water system includes a pure water host and necessary accessories. Other accessories and consumables, including wall mounted mounting brackets, purification columns, and wireless upgrade kits, are provided separately.
Please note: For U12 system, you need to order 1 RO purification column VWRI171-1276 (12 L/hour), for U24 system, you need to order 2 RO purification columns VWRI171-1276 (12 L/hour), and for U32 system, you need to order>2 RO purification columns VWRI171-1277 (16L/hour).

Ultra pure water system, U seriesspecification

model U12 U24 U32 U12 U24 U32 U24 U32
water supply Tap water (conductivity: <2000 µS/cm / TDS: <1000 ppm) Tap water (conductivity: <2000 µS/cm / TDS: <1000 ppm) Tap water (conductivity: <2000 µS/cm / TDS: <1000 ppm) Tap water (conductivity:<2000 µ S/cm/TDS:<1000 ppm) Tap water (conductivity:<2000 µ S/cm/TDS:<1000 ppm) Tap water (conductivity:<2000 µ S/cm/TDS:<1000 ppm) Tap water (conductivity:<2000 µ S/cm/TDS:<1000 ppm) Tap water (conductivity:<2000 µ S/cm/TDS:<1000 ppm)
Flow rate (l/min) Max. 2 Max. 2 Max. 2 Up to 2L/minute Up to 2L/minute Up to 2L/minute Up to 2L/minute Up to 2L/minute
Flow rate (l/hour) 12 24 32 12 24 32 24 32
Total organic carbon content <5 ppb (Type I) <5 ppb (Type I) <5 ppb (Type I) <5 ppb (I 型) <5 ppb (I 型) <5 ppb (I 型) <5 ppb (I 型) <5 ppb (I 型)
+Electrical resistivity at 25 ° C 18,2 MΩ·cm (Type I) 18,2 MΩ·cm (Type I) 18,2 MΩ·cm (Type I) 18.2 M Ω· cm (Type I) 18.2 M Ω· cm (Type I) 18.2 M Ω· cm (Type I) 18.2 M Ω· cm (Type I) 18.2 M Ω· cm (Type I)
particle No particles (with a 0,2 μm final filter or Bio filter) No particles (with a 0,2 μm final filter or Bio filter) No particles (with a 0,2 μm final filter or Bio filter) No particles (using 0.2 μ m terminal filter or Biofilter terminal filter) No particles (using 0.2 μ m terminal filter or Biofilter terminal filter) No particles (using 0.2 μ m terminal filter or Biofilter terminal filter) No particles (using 0.2 μ m terminal filter or Biofilter terminal filter) No particles (using 0.2 μ m terminal filter or Biofilter terminal filter)
endotoxin <0,001 EU/ml (with Bio filter) <0,001 EU/ml (with Bio filter) <0,001 EU/ml (with Bio filter) <0.001 EU/ml (using Biofilter terminal filter) <0.001 EU/ml (using Biofilter terminal filter) <0.001 EU/ml (using Biofilter terminal filter) <0.001 EU/ml (using Biofilter terminal filter) <0.001 EU/ml (using Biofilter terminal filter)
microorganism <0,1 cfu/ml (with a 0,2 μm final filter or Bio filter) <0,1 cfu/ml (with a 0,2 μm final filter or Bio filter) <0,1 cfu/ml (with a 0,2 μm final filter or Bio filter) <0.1 cfu/ml (using 0.2 μ m terminal filter or Biofilter terminal filter) <0.1 cfu/ml (using 0.2 μ m terminal filter or Biofilter terminal filter) <0.1 cfu/ml (using 0.2 μ m terminal filter or Biofilter terminal filter) <0.1 cfu/ml (using 0.2 μ m terminal filter or Biofilter terminal filter) <0.1 cfu/ml (using 0.2 μ m terminal filter or Biofilter terminal filter)
RNA enzyme <0,5 pg/ml (with Bio filter) <0,5 pg/ml (with Bio filter) <0,5 pg/ml (with Bio filter) <0.5 pg/ml (using Biofilter terminal filter) <0.5 pg/ml (using Biofilter terminal filter) <0.5 pg/ml (using Biofilter terminal filter) <0.5 pg/ml (using Biofilter terminal filter) <0.5 pg/ml (using Biofilter terminal filter)
DNA enzyme <10 pg/ml (with Bio filter) <10 pg/ml (with Bio filter) <10 pg/ml (with Bio filter) <10 pg/ml (using Biofilter terminal filter) <10 pg/ml (using Biofilter terminal filter) <10 pg/ml (using Biofilter terminal filter) <10 pg/ml (using Biofilter terminal filter) <10 pg/ml (using Biofilter terminal filter)
Width x Depth x Height (mm) 320×440×540 320×440×540 320×440×540 320×440×540 320×440×540 320×440×540 320×440×540 320×440×540