ImportSULFUVtypeUV fluorescence sulfur analyzerTechnical features:
1)Application areas: Liquid, solid, or gas samples, mainly used for petroleum products, and also for detecting organic materials according to methods(Such as industrial chemicals, rubber, synthetic fibers, etc);Specifically, asCrude oil, distillate oil, petroleum gas, plastics, petrochemical products, food, etc;
2)adoptUVfluorescence method(UV fluorescence method)Technology;
3)comply withASTMD 5453,AFNOR M-07-059,ISO20846,SH/T 0689standard
4)Testing principle: After the sample is burned at high temperature, mineralization effect is generated, that is, sulfur element is oxidized to formSO2Molecules, throughUVFluorescent device(When the excited stateSO2When a molecule returns to its ground state, it emitsUVLight can be captured by a photomultiplier detector)Can accurately measure its content;
5)Measurement range:0.1ppm ~10%(Related to the type and morphology of the sample), divided3The main scope;
6)accuracy:±0.05ppm(in0.2ppmtime);±15ppm(in1000ppmtime)In certain special applications, it may be better than the listed indicators; Requires minimal maintenance and simple operation;
7)Display: When the test starts,LCDdisplaySO2peak value;
8)Result calibration or analysis: When the test is completed, the instrument automatically calculates and prints the results;
9)Average analysis time: approximately5min(When analyzing liquid or gas samples); About5~15min(When analyzing solid samples, it depends on the selected programming temperature);
10)Sample size requirement:20~100ul(Liquid, injection);1~25ml(Gas, injection);0.5~100mgl(Solid, placed on a porcelain plate);
11)Instrument sizeWDH:93×55×53cmWeight: Approximately70Kg;
12)Mode conversion: It takes several minutes to switch from solid mode to liquid mode;
13)Supply requirements: The gases used are helium and argon(N55)Oxygen(N48)Power supply:220V,50Hz,1200W;
ImportSULFUVtypeUV fluorescence sulfur analyzerInstrument configuration:
1)Combustion accessories:1A quartz tube;1A combustion or high-temperature furnace with programmable heating, capable of reaching the highest temperature possible1000℃;1A combustion furnace with a constant temperature1000℃Heating, willSElemental oxidationSO2Molecular;
2)Gas control section:2A gas circuit loop that can introduce gas and oxygen, equipped with pressure and flow regulators, pressure controllers, and flow meters;
3)SO2Measurement section:1A special oneUVFluorescence detector can accurately detectSO2Content;
4)Signal acquisition, calculation, and storage: Computer and software can control:SO2Peak recording; Correction correlation coefficient; Data is saved on the hard drive; Automated operations and alerts;
5)Attachment section:1A syringe can automatically inject liquid samples at a constant speed;1A color printer can print analysis results;