● Remote communication in coal mines ● PLC equipment networking ● Industrial site network data monitoring ● CAN industrial automation control system ● Low speed CAN network data collection and analysis Online engineer telephone:

Product Details


   The GCAN-601 conversion module from Guangcheng Technology is a newly developed embedded serial port to CAN module by our company. Compared with traditional conversion modules, this module uses 3.3V power supply and is very compact in size (22 * 13mm). Users can easily integrate the module into their own developed system and connect it to the UART serial bus of the MCU, thus enabling their CAN bus to have communication capabilities quickly and easily.

  adoptUART转CANModules, PCs, PLCs, or other serial networking devices can be easily connected to CAN-BUS networks, forming control nodes for data processing, data acquisition, and data analysis in CAN-BUS network fields such as fieldbus laboratories, industrial control, intelligent communities, and automotive electronic networks. It is a powerful tool for CAN-BUS product development and data analysis. Meanwhile, the UART serial port to CAN module has the characteristics of small size and easy installation, making it a reliable assistant for engineering applications, project debugging, and product development.

The converter supports serial communication rates ranging from 600~921600bps and CAN bus communication rates ranging from 5Kbps~1Mbps.


The converter provides three directions for data conversion: bidirectional conversion, CAN only → serial, and serial only → CAN.

The converter provides three data conversion modes: transparent conversion, transparent tape identification conversion, and format conversion.



Transparent Conversion”The meaning is that a converter simply converts one format of bus data into another format of bus data without attaching or modifying the data. This achieves the exchange of data formats without changing the data content, making the converter transparent to both ends of the bus.

This method does not increase the communication burden on users, but can convert data in real-time and handle the transmission of large amounts of data.
串口转CAN

Transparent tape identification conversion”It is a special use of transparent conversion and does not come with an additional protocol. This conversion method is based on the common characteristics of serial frames and CAN messages, allowing these two different bus types to easily form the same communication network.

This method can convert the "address" in the serial frame into the identification field of the CAN message, where the starting position and length of the "address" in the serial frame can be configured. Therefore, in this method, the converter can adapt to the user's custom protocol to the maximum extent.
串口转CAN

format conversion”It is a very intuitive conversion method, where each CAN frame contains 13 bytes, which define the CAN frame information+frame ID+frame data. Using a format conversion mode converter will automatically convert the 13 bytes of CAN bus data into serial port data and send it to the serial bus. The same applies to converting serial bus data to CAN bus.
串口转CAN


  UART转CANmoduleCan quickly connect serial communication devices to CAN bus fieldbus. The module supports serial communication rates ranging from 600~921600bps and CAN bus communication rates ranging from 5Kbps~1Mbps. The module provides three data conversion modes: transparent conversion, transparent tape identification conversion, and format conversion, and is equipped with PC configuration software. Users can flexibly configure the operating parameters of the module.

The conversion between serial protocol and CAN protocol enables communication between serial devices and CAN networks. And this conversion is transparent to customers, in other words, users do not need to make any changes to the original serial communication software.

CANCOM is particularly suitable for low flow CAN bus data transmission applications, with a maximum data transmission rate of 400 frames per second. CANCOM adopts surface mounting technology and comes with an isolation module on the board, achieving complete electrical isolation between the control circuit and the CAN circuit. CANCOM also adopts lightning protection design, providing 600W lightning resistance per line, coupled with independent DC/DC power supply. This triple insurance design makes CAN-232/485 have strong anti-interference ability, greatly improving the reliability of the system in harsh environments.


Users can use CANCOM config Tools to configure the running parameters and modes of modules.

After opening the software, the interface is shown in the following figure. Select the serial port number to connect to CANCOM and click "Connect Device" to establish the connection. If the user does not know the serial port number, they can check it by entering the device manager on the PC. After clicking "Connect", the interface will pop up with "parameter reading successful", indicating that the current configuration status of the module has been read.
串口转CAN

Enter the main interface of the software as shown in the figure below. The first tab allows you to configure the conversion parameters of the module. The first part allows you to set the conversion mode and direction (as described in the above three modes and three directions). The second and third parts correspond to the parameter configuration in the "Transparent Conversion" and "Transparent Band Identification Conversion" modes, respectively. Please refer to the user manual for details.
串口转CAN
The second tab allows you to configure the baud rate and other basic parameters of the module's serial port. The serial port baud rate can support 600-115200bps, while other parameters remain default, as shown in the following figure.

串口转CAN

The third tab allows for the configuration of CAN bus transmission parameters, including basic baud rates and frame types. CAN baud rates support 1000K, 500K, 250, 200K, 125K, 100K, 50K, 20K, and 10K, while other custom baud rates are currently not supported. The sending identifier can only be set in transparent conversion, and the CAN filter settings can be found in the SJA1000 user manual or in the module user manual. )
串口转CAN


  Implement bidirectional data communication between CAN bus and UART serial ports;

  Supports CAN2.0A and CAN2.0B protocols, compliant with ISO/DIS 11898 specifications;

  Integrate 1 CAN bus communication interface, supporting user-defined communication baud rates;

  The serial communication speed can be set between 600~921600bps;

  Provide three data conversion modes: transparent conversion, transparent tape identification conversion, and Modbus protocol conversion;

  Provide three data conversion directions: bidirectional conversion, CAN only → serial, and serial only → CAN;

  Use non-volatile memory to save configuration parameters, and call the last configuration every time the power is turned on;

  The CAN bus circuit adopts DC-DC electrical isolation;

  Maximum frame rate: 400 frames per second;

  Working power supply: 3.3VDC;

  Working temperature: -40 ℃ to+85 ℃;

  Installation method: Optional standard DIN rail installation or simple fixing method;

  
Dimensions: 22mm in length and 13mm in width.


  Remote communication in coal mines

  PLC equipment networking

  Existing RS-232/RS-485 devices connected to CAN bus network

  Extended standard RS-232/RS-485 network communication length

  PLC equipment connected to CAN bus network communication

  Modbus RTU network and CAN network communication

  Gateway bridge between CAN bus and serial bus

  Industrial site network data monitoring

  CAN Teaching Application Remote Communication

  CAN Industrial Automation Control System

  Data collection and analysis of low-speed CAN network

  
CAN bus application systems such as intelligent building control data broadcasting system


Our company producesUART to CAN moduleWe adopt machine welding and mass production, all using industrial grade components, and absolutely prohibit the use of loose new or refurbished components. In order for customers to use it with peace of mind in industrial settings, we have also passed EMC tests. In addition, we have a strict factory inspection process:

----48 hour 50 ° C high-temperature aging test;

----72 hour normal temperature fault free continuous operation test;


----1Mbps baud rate, 10 million frames fault free bidirectional transmission and reception test.


----Working temperature: -40 ° C to+85 ° C;

----Storage temperature: -40 ° C to+85 ° C.