ATRT-03Transformer three-phase ratio testercharacteristic
large-scale4×20character,backlightLCDdisplay screen.
Automatic calibration before each measurement,Ensure measurement accuracy,No need for regular adjustments or temperature compensation.
The result also shows the turn to turn ratio.Winding polarity.Percentage value of excitation current and turn ratio error.
Can be paired67Automatic testing of intermediate transformer type,No need to change the wiring method.
Confirm the wiring condition with the bottom voltage first,To avoid accidents caused by misconnecting wires,Add test voltage again.
4.5Inch thermal printer
storable200Complete Transformer Test Record with Pen,Maximum per record99group data.
Can be stored128Test Plan Setting for Pen Transformer.
RS232The interface can be accessed throughPCControl and browse stored results,ASCIIThe format can be automatically analyzed.
ATRT-03Transformer three-phase ratio testertechnical indicators
model |
ATRT-03 |
ATRT-03B |
ATRT-03A |
measurement method |
ANSI/IEEE-C57.12.90 |
||
Turn ratio measurement range |
0.8~15,000(5Bit resolution) |
||
匝比精度 |
0.8~1999:±0.1%,2,000~3,999:±0.25%,4,000~15,000:±1%@8Vac 0.8~1999:±0.1%,2,000~3,999:±0.20%,4,000~15,000:±1%@40Vac 0.8~1999:±0.1%,2,000~3,999:±0.15%,4,000~15,000:±1%@100Vac |
||
test voltage |
8Vac@1A , 40Vac@0.6A , 100Vac@0.1A |
||
excitation current |
0~2A |
||
current accuracy |
±1m A,±2%Read value(±1digit) |
||
Phase angle measurement |
0~360degree |
||
相位角精度 |
±0.2degree(±1digit) |
||
printer |
4.5Inch thermal sensing type |
Nothing |
4.5Inch thermal sensing type |
display screen |
4×20character,backlightLCD |
||
Calculator interface |
RS-232C,19,200B aud |
||
Test record storage |
128Group setting/200Group test results(Nameplate voltage.匝比.Excitation current.phase angle) |
||
PCsoftware |
Window 95/98/NT/2000/XPcompatible.Standard Appendix |
||
Safety Regulations |
UL61010A-1 . CSAcertification(C22.2Nc.1010.1-92) |
||

Japan Gongli High Voltage Megohmmeter3121、3122、3123、
1Very suitable forCVInsulation testing of cables, electrical equipment, and high-voltage machines;
2Waterproof structure that can withstand even a small amount of rain;
3Dual scale display panel with automatic range mode;
4、3121High voltage megohmmeter DC test voltage2500Vmeasurement range(automatic conversion) 2GΩ/100GΩ(auto-ranging)
Main effective measurement range
precision0.1~50GΩ ±5%reading value
3121Japan Gongli High Voltage MegohmmeterAccuracy in other ranges ±10%Read numerical values or0.5%Scale value length output voltage and voltage setting indication---Voltage resistant communication5000V 1minute
power supplyR6P(AA)(1.5V)×8
Overall dimensions200(L)×140(W)×80(D)mm
weight approximately1Kg
Attachment7085(test line) 9039(Hard Carrying Case) R6P(AA)×8
User Manual
option8019(Structural probe) 8020(Recorder adapter)
3121/3122/3123Technical parameters of pointer type high-voltage megohmmeter:
|
Model Functional Parameters |
Kyoritsu3121 |
Kyoritsu3122 |
Kyoritsu3123 |
|
test voltage |
2500V |
5000V |
5000V |
10000V |
measurement range |
2G/100GΩ |
5G/200GΩ |
5G/200GΩ (auto-ranging) |
10G/400GΩ |
Once effective |
0.1-50GΩ |
0.2-100GΩ |
0.2-100GΩ |
0.4-200GΩ |
Other range accuracy |
±10%rdgor 0.5%The scale length |
±10%rdgor0.5%The scale length |
±10%rdgor0.5%The scale length |
|
pressure resistance |
5000V ACone minute |
5000V ACone minute |
5000V ACone minute |
|
battery |
R6P(AA)(1.5V)×8 |
R6P(AA)(1.5V)×8 |
R6P(AA)(1.5V)×8 |
|
volume |
200(long)×140(wide) |
200(long)×140(wide) |
200(long)×140(wide) |
|
weight |
about1kg |
about1kg |
about1kg |
|
option |
8019tester |
8019tester |
8020Recorder adapter |
|

Co branding3124High voltage insulation resistance meter
Product Introduction:
1Variable mode of rated test voltage(1kV~10kV)
2Automatic discharge function
3Double scale
4Low voltage use1000V/100MΩ Insulation resistance meter
5、3Various power supply methods(Built in batteryAC100VCar batteries)
6Recorder output port
Technical Indicators:
|
Specification Model Functional Parameters |
3124 |
|
DC test voltage |
1K-10KVadjustable |
1000V |
measurement range(automatic conversion) |
1.6GΩ/100GΩ(auto-ranging) |
100MΩ |
Main effective measurement range |
0.05-50GΩ |
1-100MΩ |
precision |
±10%reading value |
|
Accuracy in other ranges |
±1%Scale value length |
|
Output voltage and voltage setting indication |
direct current0-10KV±2%Reading value ±2bit |
|
pressure resistance |
communication5000V 1minute |
|
power supply |
nickel-Chromium rechargeable battery(1.2V)×8 |
|
Overall dimensions |
200(L)×140(W)×80(D)mm |
|
weight |
approximately1.5Kg |
|
Attachment |
7082(test line)、7083(test line)、7084(test line) |
|

5408Leakage switch tester(日本共立KYORITSU)
Product Introduction:
Easy to operate(Remote control testing)By using the remote control testing function, the test can be automatically performed by simply connecting the test line to the terminal. The initial display is the circuit voltage,1Start testing the action time or sensitivity current to automatically determine the voltage in seconds. Due to the ability to automatically distinguish100Vand200VThe measurement of circuit voltage does not require manual switching of different voltage action times. ×1/2When measuring the range, conduct a rated non operating current test. ×1、 ×5When measuring range, the action time can be testedSensitivity current test. Automatically increase the test current, indicating the current value at the time of trippingAutomatically detect contact voltage. When using a grounding wire for testing, in order to prevent electric shock caused by poor grounding, the voltage of the grounding electrode or protective conductor will be automatically detected when the test current flows. Once it reachesAC50VStop testing and issue a warning.
Dustproof and waterproof function
Backlight function
Technical Indicators:
model |
5408 |
||||
Fault state setting |
×5 |
×1 |
×1/2 |
Sensitivity current(mA) |
|
Rated operating current |
15/30/50/100mA |
15/30/50/100/200/500mA |
|||
Fault action time |
0-200ms |
0-2000ms |
0-2000ms |
300ms×15return |
|
precision |
Rated operating current |
+2%~+8dgt |
+2%~+8dgt |
-8%~-2dgt |
|
Fault action time |
1%rdg±3dgt |
1%rdg±3dgt |
1%rdg±3dgt |
||
Working Voltage |
100V±10%The200V±20%The50/60Hz |
||||
endure press |
3700Vper minute |
||||
IP |
IEC60529-IP54 |
||||
body accumulate |
186(L) x 167(W) x 89(D)mm |
||||
heavy quantity |
about960gram(Contains battery) |
||||
Appendix document |
7128、7129TheR6P(Sum-3)User Manual |
||||
option |
|||||

Fluke1625Grounding resistance tester
Fluke 1623and1625It is an excellent grounding resistance tester that can measure all four types of grounding resistance. especiallyFluke 1623and1625The measurement of grounding resistance can be completed using only one current clamp - no auxiliary pole method. This method does not require the use of auxiliary grounding electrodes or the disconnection of grounding rods.
test mode
3Jihe4 Polar potential drop method - a standard grounding resistance testing method using two grounding electrodes.
Selection method test - without disconnecting the grounding rod, the grounding resistance can be measured using a combination of grounding electrode and current clamp.
Non auxiliary pole method - a highly innovative testing solution that does not require the use of grounding electrodes and can measure the resistance of the grounding loop using only current clamps.
Fluke 1625It also provides the following advanced features
Automatic frequency control(AFC)Automatically identify interference and select measurement frequency to minimize the impact of interference and provide more accurate grounding resistance values.
R*Measurement - Calculation in55 HzThe grounding impedance below more accurately reflects the true grounding resistance when a grounding fault occurs.
Adjustable limit value - can quickly check test results.
Fluke 1625 GEOCharacteristics of grounding resistance tester:
3Jifa and4Measurement of Polarized Grounding Resistance
4Polar method for measuring soil resistivity
2Polar method for measuring AC resistance
2Jifa and4Polar method for measuring DC resistance
Selection method test, no need to disconnect the grounding connection(1Current clamp)
Without auxiliary pole method, quickly test the grounding loop(2Current clamp)
measurement55 HzGround impedance below
Automatic frequency control(AFC)(94、105、111The128 Hz)
Voltage measurement switchable20/48V
Programmable limits and settings
On/off test with buzzer sound prompt
Fluke 1625/1623 GEOGrounding resistance tester
RA 3Measurement of Polarized Grounding Resistance(IEC 1557-5) |
||||||||
measure voltage |
|
|||||||
short-circuit current |
|
|||||||
measurement frequency |
|
|||||||
resolution |
|
|||||||
Measurement range |
|
|||||||
Basic error |
|
|||||||
working error |
|
|||||||
RA 4Measurement of Polarized Grounding Resistance(IEC 1557-5) | ||||||||
measure voltage |
|
|||||||
short-circuit current |
|
|||||||
measurement frequency |
|
|||||||
resolution |
|
|||||||
Measurement range |
|
|||||||
Basic error |
|
|||||||
working error |
|
|||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke 1625 GEOGrounding resistance testerGEOGrounding resistance tester
|
Fluke 1625tester 2 Test line battery User Manual |
Fluke 1625 kit GEOGrounding resistance testerGEOGrounding resistance tester
Tool kit, advancedGeoGrounding resistance tester
|
Fluke 1625tester 2 Test line 4 Root grounding rod 3 Rolling wire(2 roll 25 Mi,1 roll 50 Rice) 2 A clamp table (one for induction and one for detection) battery User Manual Durable and sturdy portable bag
|
DigiTMRCircuit breaker time mechanical characteristic tester
characteristic
Analysis of complete operation of circuit breaker contacts:
Open, close, open-Close, close-Open, open-close-open
Analyze contact time,stroke,speed
3A dry contact input channel:
Can detect the main contact and insertion resistance contact time
2A voltage input channel:
A monitoringDCPower supply or coil resistance(0-300Vdcorpeak ac),The second monitoringA/BSwitching voltageON/OFFBuilt in status
CT:Recordable jumps/Closing current level and duration
1A digital stroke sensor channel:Measure stroke,Overshoot and bounce back
No calibration or setting required,Computable speed
storable100Pen result recording and99Group testing setup
Built in thermal printer
model |
DigiTMR |
Dry contact input |
3A dry contact input;Can detect the main contact and insertion resistance contact time |
Timing length |
1sThe10sThe20s(optional) |
Timing resolution |
1During the second period, it is ±100Ms; 10During the second period, it is ±1.00ms; 20During the second period, it is ±2.00ms |
Timing accuracy |
±0.05%Reading value ±0.1ms@1During the second period |
Dry contact channel protection |
Fuses protect all isolated power sources;All contact inputs are grounded before testing; TVSHejina diode protection |
Contact detection range |
Closed:<20Ω,Open:>5000Ω |
Resistance detection range |
50~5000Ω |
Trigger input voltage |
open/Closed:30~300Vdcorpeak ac |
Voltage sensing input range |
V1:Analog input;0-255Vdcorpeak ac,sensitivity:±1V V2:Voltage Sensing(have/Nothing)input;30-300Vdcorpeak ac |
Circuit breaker operation |
Open, close, open-Close, close-Open, open-close-open |
Initial capacity of circuit breaker |
30A/250Vac/dc max |
Initial current range |
1A non-contact Hall effectCT,scope0-20A,dc~5kHz |
Stroke sensor input |
1A digital stroke sensor channel;Linear range:0-60in(±0.005in) Rotation range:0~360°(±0.006°) |
Point difference value of contact stroke |
Measurement "Slow-close”Distance between contact points |
display screen |
4lineX 20character,backlightLCD |
printer |
4.5Inch thermal printer,Printable contact stroke graphics and numerical table |
Test data storage |
100Pen result recording and99Group testing setup |
computer interface |
RS-232C, 19,200 Baud |
PCsoftware |
Windows® 95/98/NT/XPStandard attachments |
Safety Regulations |
Design complies withUL 61010A-1TheCAN/CSAcertification(C22.2 No. 1010.1-92) |

CBPS-300Circuit breaker DC power supply
characteristic
Adjustable voltage DC power supply controlled by microprocessor
Can replace substation batteries when testing circuit breakers
Can be easily based onANSI C37.09orIEC 56Test the minimum tripping voltageOverload current protection.
2×16Character, backlightLCD.
Can be used for testing circuit breakers,Operate open and closed line diagrams in full voltage mode or minimum voltage condition.
can be paired withCT-6500S2/7000S2/7500S2/8000Used in combination.
display screen |
2×16Characters, backlightLCD |
|||||
DCvoltage value |
0~300VDC,±1V |
|||||
coilDCpower supply |
DCoutput |
current |
Adjustment degree |
|||
24Vdc |
10A |
<6% |
||||
48Vdc |
10A |
<3% |
||||
120Vdc |
6A |
<2% |
||||
250Vdc |
3A |
<2% |
||||
The interval between opening and closing is only1second | ||||||
Starting circuit |
Built in solid-state initial circuit for opening and closing |
|||||
Charging motorDCpower supply |
No load voltage |
load current |
Load interval |
Full load voltage |
||
48Vdc |
12A |
60s |
40Vdc |
|||
48Vdec |
18A |
20s |
30Vdc |
|||
120Vdc |
12A |
60s |
90Vdc |
|||
120Vdc |
18A |
20s |
70Vdc |
|||
240Vdc |
6A |
60s |
200Vdc |
|||
240Vdc |
9A |
20s |
185Vdc |
|||
Output protection |
All DC outputs are protected against overcurrent |
|||||
Safety Regulations |
UL 61010A-1TheCAN/CSA(C22.2 No. 1010-92) |
|||||
conductor |
10Three sets of inch wires, one set of grounding wire and one set of power wire, and one wire carrying bag |
|||||

LM 2000portableSF6Gas leak detector
application:
Factory gas or on-siteSF6Leakage detection of gas insulated power equipment,for example:Power circuit breakers, enclosed switchesSF6Insulated transformers, etc. UV lamp ionization method,Oxygen andSF6in the air,Will ionize due to ultraviolet radiation,Therefore, taking advantage of its mobility differences,It can easily and quickly measure small amounts in the airSF6The concentration.
characteristic:
Gas flow sampling,It can be controlled by the flow controller on the front panel to increase the sampling flow rate in windy conditions,To maintain accuracy.
Large LCD display screen: SF6concentration(ppm),Leakage rate(ml/s),Annual leakage rate(g/y)Directly displayed on the screen with high stability and sensitivity,Not affected by environmental temperature or humidity.
The built-in calibration software can perform single point self calibration and multi-point standard calibration.
storable50Pen test results
specification |
|
Measuring gases |
SF6gas |
measurement range |
0 ~ 100 ppm |
detection sensitivity |
1 ppm |
Reproducibility accuracy |
±5 %Full scale |
response time |
4second(Depending on gas flow rate and pipeline length) |
Traffic rate |
0 ~ 30 L/H |

DP99-IIIDigital dew point meter
Portable instruments designed for on-site and factory use,Used to measure industrial gases,for example: SF6, N2,The water content inside.
high precision,Short term measurement,And it is easy to operate.
characteristic:
Short term measurement:Using digital control to significantly reduce measurement time,Generally, on-site measurements only require an average of3-5minute.
Save gas:Due to short-term measurement,The gas consumption required for a single measurement is significantly reduced.
ppmRead value:Equipped with a large screen displaying dew point temperatureppmNumerical values, graphs of equilibrium processes, flow rates, etc.
Built in printer.
working principle:Principle of Frozen Mirror Surface-Composed of four parts:lighting system,cooling system,Gas system,Control and Measurement System
specification |
||
-55℃ |
At ambient temperature23At ℃ |
|
precision |
≤ ±0.2°C,± 1 digit(typical) |
|
reproducibility |
≤ ±0.1°C,± 1 digit |
|
Read value |
Dew point temperatureppmVBalance process graphics, flow velocity |
|
Measuring principle |
Dew point mirror, electroplated rhodium(rhodium)Optical detection |
|
cooling |
ThermoelectricPeltier-Battery4step |
|
Sampling gas flow rate |
15 ~ 60 l/h,rated30 ~ 40 l/h |
|
Sampling gas pressure |
minimum10 mbar,reachable10 bar (1 kPa ~ 1 MPa) |
|
response time |
2℃/second |
|
Mirror inspection |
Choose 'CHK”Menu-button,Perform manual inspection |
|
alarm |
No gas/The flow rate is too high/照明太暗/unbalanced |
|

Single phase relay protection testerSverker 780/760/750/650
characteristic
Test all single-phase protection and automatic reclosing tests
Output up to250A
Can communicate with computers
Output up to200A
Can communicate with computers
It can also measure impedance(Z)Resistance(R)Reactance(X), meritorious service(p)Visual power(S)Reactive power(Q)Power factor(cosBoth current and voltage can be used as benchmarks, such as ф, etc
10Group testing storage, automatic testing of different types
Reading lock (hold) function. Easy to record
Integrated design integrates voltage, current sources, and meters for easy use
Technical Specifications
AC current output:
scopeA |
No load voltage(V) |
Full load voltage(V) |
Full load current(A) |
Carrying load/Recovery time (minutes) |
0-10 |
90 |
75 |
10 |
2/15 |
0-40 |
25 |
20 |
40 |
1/15 |
0-100 |
10 |
8 |
100 |
1/15 |
0-100 |
10 |
-- |
250 |
1second/15minute |
communication/DC voltage output:
scope |
No load voltage(V) |
Full load voltage(V) |
Full load current(A) |
Carrying load/Recovery time (minutes) |
0-250V AC |
290 |
250 |
3 |
10/45 |
0-300V AC |
320 |
250 |
2 |
10/45 |
Assisted communication/DC voltage output:
Voltage range(V) |
No load voltage(V) |
Full load voltage(V) |
rated current(A) |
0-60VAC |
70V |
60V |
0.25A |
60-120VAC |
130V |
120V |
O.25A |
20-130VDC |
130V |
O.4A |
|
130-220VDC |
220V |
O.4A |
Other parameters
timer:LEDdisplay0.000-999.9S,The accuracy is:1ms;
Ammeter: Internal0.00-200.0A;外部0.000-6.000A;
Accuracy: Internal Range:0.5%External range:AC 0.5% / DC 0.5%;
Voltage meter: Range0.00-600.0V; AccuracyAC 0.5%,DC 0.5%;
Phase angle: Range0-359°, accuracy1°;
volume350×270×220mm;
weight: 18kg.

S8000Cold mirror dew point meter
Range:-60℃-- +40℃dp
The dual path system has good sensitivity and automatic compensation for changing gas temperatures
Measurement resolution:0.001℃
Articulated sensors make monitoring and cleaning of mirrors easy
All real-time measurement results are displayed
Multiple units display:dp + temp°C +°F
%rh, g/m3, g/kg
ppm(v), ppm(w) SF6
ml/min,
psia, Bar, Kpa
Quick measurement display
pressure20bara
throughSDCard andUSBInterface for data collection of pressure, humidity, and flow rate
high-resolutionLCDdisplay screen
The menu operation is simple and convenient

TAP-4On load voltage regulating switch analyzer
The first instrument that uses vibration acoustic analysis to detect faults in on load voltage regulating switches.
Non invasive testing of transformers in operation (testable)800kVTransformer)
TAP-4Can identify various electrical and mechanical issues:
Contact wear
Driver and synchronization issues
Brake failure
Abnormal arc
This non-invasive testing method immediately diagnoses on load voltage regulationThe status of the switch and the issues it has.
New means of status maintenance
Transformer on load tap changer(OLTC)It is a component with heavy workload for transformers,He moves several times a day,According to statistics,Transformer malfunction40%Caused by on load voltage regulating switch. The on load voltage regulating switch needs maintenance, and lack of maintenance may cause problemsThe consequences of fear and significant property damage.
Vibration Acoustic Analysis
Thanks to the innovative testing method based on recording vibration acoustic signal analysis,TAP-4Conduct a complete inspection of the interior of the on load voltage regulating switch,And there's no need to open him.
Vibration acoustic analysis has a history of more than ten years in the development and testing of hydropower in Quebec, Canada. This diagnostic method has been usedGuidelines for maintenance of two transformersIEEE. PC57.143andCigreA2,34Recognized.
DIACThe core of problem-solving
DIACSoftware driven from a simple interfaceTAP-4Thanks to the vibration signal analysis technology,DIACexplanationRecord the events and report them to the operator in a color chart.
This makes it possible to quickly diagnose and accurately and efficiently maintain on load voltage regulating switches.
Advantages:
Applicable to all on load voltage regulating switches(ABBRheinhausen,GEWestinghouse
Fast, automated testing sequence (less than)10Minutes)
Simple and minimal operational testing(+1TAPEvery test)
Automatically create easy to understand Colorful report
For the majorityOLTCThe testing plan
Based on exceeding1000Taiwan's accumulated experience
Statistical analysis of distribution and types
Provide the result of a single tap
Fast, online diagnosis
trend analysis
Recording data is easy to classify
Comparison of different test results