Transformer partial discharge system

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The main purpose of the partial discharge system test for transformers is to detect the phenomenon of partial discharge inside the transformer, including parameters such as amplitude, frequency, and duration of partial discharge, in order to determine the insulation performance and safety reliability of the transformer. Partial discharge refers to the phenomenon where an insulating medium does not "penetrate" throughout its entire thickness, but only generates discharge in a localized area of its thickness.

Product Details

UHV (W) -35KV transformer without partial discharge withstand voltage test device

1、 Meet the scope of the test sample

1. Test voltage less than 35kV

2. Configuration List

2、 Main components of the device

serial number

Device name

Model

unit

quantity

prepare note

1

No partial discharge voltage withstand test device

UHV(J)-35kv

platform

1

Including regulator

2

Power frequency non partial discharge test transformer

YDQ-30kVA/100kV

platform

1

No local deflation change

3

Single phase low-pass filter

UHV- 30KVA.

platform

1

Voltage regulator output filtering

4

Non partial discharge coupling capacitor

UHV-100kV

platform

1

800pf

5

Isolation transformer

UHV- 30 kVA.

platform

1

Power isolation

Separation filtering

6

Partial discharge detection system

UHV-2000A

platform

1

with attachment

IIIMain functions and features

3.1Non partial discharge coupling capacitor

变压器局放系统


1 purpose

Non partial discharge coupling capacitor( hereinafter referred to as“ capacitor ”)use Measurement of partial discharge in high-voltage electrical equipment.

2 Meaning of Model

Main specifications and technical parameters

Preface number

type number

rated voltagekV

Rated capacitance

PF

outside Shape ruler inch ¢ × H mm

weight

kg

1

60-0.001

60

1000

160×740

13

2

120-0.0005

120

500

160×900

28

3

100-0.001

100

1000

160×900

28

4

120-0.001

120

1000

160×900

28

5

150-0.002

150

2000

160×1300

29

6

250-0.0005

250

500

160×2000

32

3. Environmental conditions for use

1 、The altitude of the usage area shall not exceed 1000m, The ambient air temperature range is -25+45℃。

2 、When using the productThe relative humidity of the surrounding air should not exceed 80%.

4. Main technical performance

1、 Capacitors at rated voltage UN Can run continuously below 1 Hour.

2、Deviation range of capacitor capacitance:-5+10%CN 。

3、 electricity Rong device between quality damage consume Jiao Zheng Cut value : in 20 ℃ N,0.9 Under 1.1 UN No greater than0.002.

4、 The short-term power frequency withstand voltage value of the capacitor is 1.1UN 。

5、 Capacitor at nominal value Partial discharge capacity at 100% voltage: ≤5PC

6、 Rated voltage100kV

7、 Nominal capacitance:800pF

8 、Measurement uncertainty:≤1%

9 、Power frequency withstand voltage level:100kV/1min

5. Main structure

1、 A capacitor consists of a casing, end cap, core, impregnating agent, and expansion pinComposed of a tensioner, base or support frame, and low-pressure seat.

2、 The shell is a vacuum impregnated epoxy sleeve

3、 The core is composed of several components connected in seriesThe components are made of all paper or paper film composite, and the core is genuineAfter air drying, immerse in excellent insulating oil.

4、 After impregnating the capacitor, a certain amount of oil pressure is applied, Caused by the expander's response to temperature changesCompensate for changes in oil volumeTo ensure that there is no negative pressure inside the capacitor at operating temperature.

Exterior diagram

变压器局放系统


变压器局放系统

1 Scope of application

Conduct partial discharge tests on dry-type transformers and other products using an intermediate frequency generator set, when the unit rotates at high speedWhen turning,The spark discharge generated between the carbon brush and the rotor will be tested in partial dischargeMore than on the road 10000pC ofBackground noise makes it impossible to conduct the experiment. This product is designed specifically for this type of testing circuit,Can effectivelyIsolate and attenuate spark discharge signals and various interference signals from the power supply side.

2 Electrical schematic diagram

变压器局放系统



3 Main technical parameters

1. Three phase;

2、 Rated frequency:100-200Hz;

3、 Rated input line voltage:800V,

4 、right 10kHz~300kHz The attenuation ability of interference signals is highYu 80dB。

5 、After connecting the product, the background partial discharge from the power side is less than3pC.

(Background noise from spatial coupling to partial discharge testing circuit should be eliminated)

4、 Product Features

1、 The primary and secondary coils of the isolation transformer are enclosed, The product has an electrostatic screen protector set in the middleGood isolation function.

2、 The inductor coil adopts an open circular iron core, which can ensure the inductance valueHas good linearity,It can also minimize its own iron loss to a certain extent.

3 、Reasonably select capacitance and inductance parameters to ensure that the product has sufficient attenuation factorsWhen the three-phase currents are basically symmetrical, the output voltage is also basically balanced.


5The transformer without partial discharge AC test meets the following indicators

1. Rated capacity: 30kVA;

2. Rated output voltage: 0-100kV;

3. Rated output current: 0-0.3A;

4. Rated input voltage: 0-400V;

5. Rated input current: 0-75A;

6 Instrument voltage:0~100V

7. Partial discharge capacity: less than rated voltage 3pc

four.UHV-2000A+Technical parameters of partial discharge detector

变压器局放系统


4.1Product execution standards

Ø GB/T16927--------- "High Voltage Test Techniques"

Ø IEC60270- Partial Discharge Measurement

Ø GB/T7354- Measurement of Partial Discharge

Ø GB1094------------- "Power Transformers"

Ø IEC6067.11- Dry type Transformers

Ø GB1207- Voltage Transformers

Ø GB1208- Current Transformers

Ø DL417 Guidelines for On site Measurement of Partial Discharge in Power Equipment

Ø GB12706.4 Test Requirements for Power Cable Accessories

Ø IEC60885-3- Partial Discharge Test for Whole Squeezed Cable

Ø GB/T3048.12--- "Test Methods for Electrical Properties of Wires and Cables - Partial Discharge Test"

Ø DL/T 846.4-2004- General Technical Conditions for High Voltage Testing Equipment Part 4: Partial Discharge Measuring Instruments

4.2Main technical indicators

Technical Characteristics

Technical characteristics


number of channels

Number of interfaces

independent4通道

Free-running 4 interfaces

sampling rate

Sampling rate

1MThe5MThe10MOptional

1M. 5M. 10M selected

sampling precision

Sampling accuracy

12bit

12bit

Range switching

Range changing

-40dB, -20dB, 0dB, 20dB, 40dB, 60dB, a total of 6 levels

-40dB, -20dB, 0dB, 20dB, 40dB ,60dB, totally 6 types

Measurement frequency band

Measurement frequency range

3dBbandwidth10kHz~1MHz

3db bandwidth10kHz~1MHz

digital filtering

Digital filtering

10kHz~1MHzarbitrary selection

10kHz~1MHz freely selected

Segmented programmable filter

Program controlled filter subsection

Low end frequency:10kHz,20kHz,40kHz,80kHz

Low frequency: 10kHz,20kHz,40kHz,80kHz
Frequency:100kHz,200kHz,300kHz,400kHz

High frequency:100kHz,200kHz,300kHz,400kHz

Nonlinear error of this range

Nonlinear error in the range

10%

10%

measurement range

Measurement range

0.1pC~100,000pC

0.1pC~100,000pC

sensitivity

Sensibility

0.1pC

0.1pC

The capacitance range of the testable product

Capacity range of the measured product

6pF~250µF

6pF~250µF

Test power frequency range

Frequency range of test power

50~500Hz

50~500Hz

display

Display


display screen

Display screen

12” TFTTrue color touch LCD display screen

12’’ TFT true color touchable LCD screen

resolution

Resolution

1024×768

1024×768

interface

Interface


USB

USB

3 channels, capable of external mouse and keyboard, as well as external mobile storage devices

3 types, use of external mouse, keyboard or other USB devices.

Power mode

Power mode

AC 220V; frequency50Hz; Power300W

AC 220V; Frequency50Hz; Power300W

Electrical signal interface

Electric signal interface

4 routesBNCInterface, used for signal input

4 BNC interfaces, use of signal input.

Optical signal interface

Optical signal interface

4 channels, used for signal input

4 types, use of signal input

Ethernet port

Network interface

1 Road

1 type

Grounding button

Landing button

external grounding

External landing

General Instructions

General instruction


CPU

CPU

clock rate1.60GHz

Basic frequency 1.60GHz

memory

Ram

2.0GB

2.0GB

hard disk

Hard disk

128GB Solid State Drive

128GB SSD

system

System

Windows Xp

Windows Xp

working environment

Operating environment

Ambient temperature-10~45℃ Relative humidity:≤95%

Environment ambient:-10~45℃ Humidity:≤95%RH

size

Size

longWidth and height: 474mm, 288mm, and 370mm

Length×width×height: 474mm × 288mm × 370mm

weight

Weight

15.8kg

15.8kg

4.3Product feature description

The partial discharge comprehensive analyzer is 4Channel, desktopTFTLCD display, reliable system, low failure rate. In addition to being used for partial discharge measurement of high-voltage electrical equipment (standard), it also has the function of accurately locating the fault point of faulty equipment (optional), and can also be used for online continuous monitoring of partial discharge of high-voltage electrical equipment such as large power transformers (optional). Truly achieving the integration of partial discharge measurement, positioning, and online monitoring functions. This local discharge device is a specialized instrument for measuring and analyzing the insulation performance of power equipment. This system adopts modern electronic and computer integrated technology to achieve signal amplification (analog, electronic, digital), filtering, data acquisition, data processing, graphic display, and automatic generation of test reports, thereby completing partial discharge measurement and fault diagnosis.

The scope of application, detection method, test circuit, technical performance parameters, etc. of this discharge device comply with international standardsIEC 60270-2000National standardsGB/T 7354-2003Partial Discharge MeasurementDL/T 417-2006The standard requirements of "Guidelines for On site Measurement of Partial Discharge in Power Equipment".

6、 Supply List

Prefacenumber

set prepare name call, name, say, weigh

type number and rule grid

unit

quantity

1

No partial discharge voltage withstand test device

UHV(J)-35kv

platform


2

Power frequency non partial discharge test transformer

YDQ-30kVA/100kV

platform


3

Single phase low-pass filter

UHV- 30KVA.

platform


4

Non partial discharge coupling capacitor

UHV-100kV

platform


5

Isolation transformer

UHV- 30 kVA.

platform


6

Partial discharge detection system

UHV-2000A+

platform


7

test linepackage


set

1

8

Factory inspection report


share

1

9

User Manual


share

1

10

Product Qualification Certificate


share

1

11

Packing List


share

1

7、 Reference experimental standards

GB10229

electricityAnti weapons

GB1094

electricityPower Transformer

JB/T 9641

Test Transformer

GB/T311.1

tallpressInsulation and coordination of power transmission and transformation equipment

GB/T 16927

tallVoltage testing technology

GB7354

Partial discharge measurementquantity

GB4208

outsideShell protection level

GB/T 15164

Oil immersed power transformer load conductorthen

GB2900

electricityworkNoun terms

GB5273

changeWiring terminals for compressors, high-voltage electrical appliances, and bushings

GB2536

changeCompressor oil

GB7328

changeSound level measurement of voltage regulator and reactor

GB5027

electricityTypical Fire Protection Regulations for Power Equipment

GB10237

electricityInsulation level of power transformer and air gap of external insulation for insulation test

DL/T849.6-2004

electricity力General technical specifications for equipment specific testing instrumentsPart 6: High Voltage Resonance Test Equipment

place

DL/T848.3-2004

high pressuretryGeneral Technical Conditions for Testing Devices Part 3: Transformer without partial discharge test

GB4793-1984

electricitySafety requirements for sub measuring instruments

GB/T2423.8-1995

electricityBasic Environmental Testing Regulations for Industrial and Electronic Products

GB/T3859.1-1993

Basic requirements for semiconductor invertersfixed

GB/T3859.2-1993

Semiconductor inverter Application guide

GB 50150-2006

Electrical Equipment Handover Test Standard for Electrical Equipment Installation Engineeringaccurate