- Phone
-
Address
Liubao Town Industrial Concentration Zone, Baoying County, Jiangsu Province
Yangzhou Haiwo Electric Technology Development Co., Ltd
Liubao Town Industrial Concentration Zone, Baoying County, Jiangsu Province
Transformer comprehensive characteristic testerMain features
• Support detection of CT and PT
Meet the requirements of regulations such as GB1207 and GB1208
Without the need for external equipment, all testing items can be completed on a single machine, and excitation and variable ratio polarity tests can be completed simultaneously in one test.
Equipped with a miniature fast printer, it can directly print test results on site
Easy to operate with intelligent prompts, making it easier for users to get started. .
Large screen LCD with graphical display interface
Automatically provide CT/PT (excitation) inflection point values according to regulations
Automatically provide 5% and 10% error curves
Can save 3000 sets of test data without losing it after power failure
Supports USB flash drive data transfer, which can be read through a standard PC and generate WORD reports
Small and lightweight ≤ 28Kg, very conducive to on-site testing
Transformer comprehensive characteristic testerThe main testing functions of the tester are:
CT (protective, metrological) |
PT |
Voltage current characteristic (excitation characteristic) curve |
Voltage current characteristic (excitation characteristic) curve |
• Automatically provide inflection point values |
• Automatically provide inflection point values |
Automatically provide error curves of 5% and 10%, with measurable limit factor actual value (ALF) |
• Ratio measurement |
• Ratio measurement, polarity judgment |
• Polarity judgment |
• Differential measurement |
• Differential measurement |
• Phase (angle difference) measurement |
• Phase (angle difference) measurement |
• One flow test |
• Communication voltage withstand test |
• Communication voltage withstand test |
• Secondary load test |
• Secondary load test |
Secondary winding direct resistance test |
Secondary winding direct resistance test |
• PT volt ampere voltage multiple adjustable (1.2-3.5) |
• Measurable volt ampere characteristics of medium and low voltage transformers, zero sequence transformers |
|
• Measurable GIS, casing CT |
|
Comprehensive testing, completing excitation and variable polarity simultaneously in one test |
Main technical parameters of the tester:
Project |
Parameters |
|
working power supply |
AC220V±10% 、50Hz |
|
Device output |
0-2500V 5KVA maximum setting value 20A |
|
High current output |
0~1000A |
|
Excitation accuracy |
≤ 0.5% (0.2% * reading+0.3% * range) |
|
|
secondary winding resistance measurement |
scope |
0.1~300Ω |
precision |
≤ 1.0% (0.4% * reading+0.6% * range) |
|
|
Secondary actual Load measurement |
scope |
5~500VA |
precision |
≤ 0.5% (0.2% * reading+0.3% * range) ± 0.1VA |
|
|
phase measurement (Angle difference) |
precision |
4min |
resolution |
0.1min |
|
|
CT Variable ratio measurement |
scope |
≤50000A/5A(10000A/1A) |
precision |
≤ 0.5% (0.2% * reading+0.3% * range) |
|
|
PT Variable ratio measurement |
scope |
≤500KV |
precision |
≤ 0.5% (0.2% * reading+0.3% * range) |
|
working environment |
Temperature: -10 ℃~40 ℃, humidity: ≤ 90%, altitude: ≤ 1000m |
|
Size and weight |
Dimensions: 450mm × 280mm × 340mm, Weight: ≤ 28Kg |
|