Total phosphorus analyzer, online analyzer for total phosphorus water quality
Total Phosphorus Analyzer, Total Phosphorus Water Quality Online Analyzer TPComply with the national environmental monitoring standard HJ/T 103-2003 Technical Requirements for Total Phosphorus Water Quality Automatic Analyzer and other relevant standards and specifications, and measure the total phosphorus content in water according to GB/T GB11893-89 Determination of Total Phosphorus in Water Quality - Ammonium Molybdate spectrophotometric method. Mainly used for online monitoring of water quality in fixed pollution sources (industrial wastewater discharge, aquaculture wastewater discharge, domestic sewage discharge), surface water, groundwater, drinking water sources, nearshore waters, and nearshore waters.
|
measurement method |
National StandardGB/T GB11893- 89Determination of Total Phosphorus in Water QualityAmmonium molybdate spectrophotometric method |
|
measurement range |
010mg/L、050 mg/L、0200mg/LThree range options are available, and other range options can be expanded according to customer requirements . |
|
zero drift |
±0.2%F.S.(Test environment: Potassium dihydrogen phosphate standard Quasi test solution); |
|
Span Drift |
±0.8%F.S.(Test environment: Potassium dihydrogen phosphate standard Quasi test solution); |
|
indication error |
±1.0%F.S.(Test environment: Potassium dihydrogen phosphate standard Quasi test solution); |
|
heavyagainsex |
≤ 0.5%F.S.(Test environment: Potassium dihydrogen phosphate standard Quasi test solution); |
|
measurement period |
Minimum measurement cycle45minute |
|
calibration cycle |
The three calibration modes of "once a week", "twice a month", and "once a month" are optional. |
|
maintenance cycle |
At least once a month, with each appointmentone hour. |
|
dissolution temperature |
The recommended temperature is120℃Customers can set the color temperature according to the actual water sample situation. |
|
incubation time |
The recommended time is10 minCustomers can set the constant temperature time according to the actual water sample situation. |
|
weight |
65kg |
|
size |
550mm × 420mm × 1310mm (L×W×H) |
|
Power adaptability |
AC220V±10%,50Hz±1%Suggest equipping with1KWThe communication purification and voltage stabilization power supply. |
|
environmental adaptability |
5~45℃Relative humidity(65
± 20)%No condensation. |
|
Digital communication interface |
RS-232 |
|
Analog output interface |
industrial standard4-20 mAoutput |
|
Human computer interaction mode |
7inchLCDTouch screen, Chinese display, and command input. |
|
storage capacity |
At least one year of data storage capacity, never lost in case of power failure. |
|
Automatic recovery function |
Abnormal alarm or automatic processing, and after processing, it will automatically return to its original working state. |