Product Name: Dental Module Staining Instrument
Specification ModelJR-2
Tooth module staining instrument, brushing and grinding instrument, toothpaste efficacy evaluation instrument
1Introduction to dental module staining instrument:
Dental moduleStainer: equipped with a rotating wheel connected to an electric motor, a carrier capable of accommodating dental grinding blocks on the rotating wheel, a water tank of a certain capacity below the rotating wheel, and a rotating speed greater than or equal to2r/minAfter staining the dental module, it is necessary to use a brush grinder for brushing and grindingThe pressure value can be adjusted separately and tested in real-time through experimental monitoring, greatly improving the accuracy and reliability of testing. All toothbrushes use8Independent pressure sensors, each independent module can measure and calibrate, eliminating pressure unevenness caused by mechanical manufacturing, workpiece installation, tooth module preparation and processing, etc,Adjustable brushing load and frequency, controllable brushing load(Precision0.1g).
The dental module staining instrument is based onT/COCIA7-2020,GB/T43576-2023Laboratory evaluation of toothpaste efficacy in removing exogenous pigmentation,GB/T35832-2018The method for detecting the friction value of toothpaste requires design and development.
The dental module staining instrument adopts a constant temperature sealed air source chamber, simulating the uniform characteristics of the human oral cavity. The temperature control is precise and stable, ensuring uniform temperature while avoiding temperature overshoot and large fluctuations. It is not affected by uncontrollable factors such as environmental temperature and humidity during staining. The servo motor can rotate continuously for a long time. adopt12The high magnetic level magnetic block is used to fix the tooth base on the base, which is convenient and easy, without damaging the tooth base due to external forces such as running during rotation or friction from the fixture. The same batch of teeth can be dyed with no less than110A dental module ensures the uniformity and consistency of teeth dyed in the same car to a large extent without damaging the surface of the dental base, shortening the staining time of the dental module and improving the efficiency of high batch experiments.
The dental module staining instrument has a beautiful and elegant appearance, a reasonable structure, simple operation, durability, and good repeatability,The cavity adopts304High quality stainless steel, easy to clean and disassemble after dyeing. The software has rich content, clear interface, and simple operation. The motor control adopts servo motor closed-loop control, with precise speed and stable operation.
Dental module staining instrumentApplicable standards:GB/T40002-2021TheISO11609TheT/COCIA7-2020TheISO28399TheGB/T43576-2023TheYY/T1829-2022TheGB/T35832-2018Wait.
IIMain technical parameters of dental module staining instrument:
1Magnetic base:12bit
2Number of dental module installations: ≥110piece
3Working power supply:220V AC,50/60HZ
4Equipment power:650W
5Heating power:150W
6Temperature control range: from room temperature to50℃ adjustable
7Temperature accuracy:37℃±1℃
8Wheel speed: 1-60r/min ± 1%, can be calibrated and measured
9Lighting method:LEDfluorescent tube
10Working hours:0.5-4500minConfigurable
11Display screen size:5Inch LCD screenNote: Our company produces and sells dental module brushing and grinding equipment, dental module staining equipment, various specifications of dental modules, and anti sensitive dentin tablets. If you need them, please contact our sales personnel for consultation!

Tooth module staining instrument, brushing and grinding instrument, toothpaste efficacy evaluation instrument
Product Name: Tooth Module Brush Grinding Instrument
Specification ModelHDSY-II
1Dental module brush grinderMain purpose and working principle
Dental module brush grinderMainly used for research, testing institutions, and manufacturers of oral cleaning and care products to evaluate the stain removal and whitening effects, as well as the removal of external color spots, of products such as toothbrushes, toothpaste, oral cleaning and care fluids, dental patches, tooth powders, electric toothbrushes, teeth whitening agents, grinding rods, active tooth cleaners, and other raw materials such as friction agents, moisturizers, thickeners, foaming agents, taste improvers, and fragrances. Its evaluation and measurement method imitates the mechanical process of human tooth brushing, and synchronously performs reciprocating brushing and grinding through mechanical transmission to control the testing unit, which is closer to the actual brushing conditions. The equipment consists of eight brushing and grinding units, which can work simultaneously under the same conditions, improving the accuracy of the experiment and increasing work efficiency.
The dental module brushing and grinding instrument and dental module staining instrument are based onT/COCIA7-2020,GB/T43576-2023Laboratory evaluation of toothpaste efficacy in removing exogenous pigmentation,GB/T35832-2018The method for detecting the friction value of toothpaste requires design and development.
The pressure values of the dental module brush grinder are individually adjusted, and the working pressure values can be monitored in real time during experimental testing, greatly improving the accuracy and reliability of the testing. The dental module brushing and grinding instrument adopts8Independent pressure sensing module, each independent module can measure and calibrate, eliminating pressure unevenness caused by mechanical manufacturing, workpiece installation, tooth module preparation and processing, etc. The dynamic pressure of the tooth module brushing and grinding instrument is ≤30gfThis value can be measured and calibrated, and is superior to the requirements of relevant standards. The dental module brush grinder adopts8An independent test solution sample cup is provided to avoid cross flow contamination of the test samples, which may affect the accuracy of the experiment. Each test solution sample cup is easy to disassemble and assemble, making it convenient for cleaning and washing after the experiment is completed. This avoids long-term accumulation of cleaning residues on the equipment and testing environment caused by experimental testing.
Applicable standards:GB/T43576-2023TheT/COCIA7-2020TheISO11609TheISO28399TheGB/T40002-2021TheYY/T1829-2022TheGB/T35832-2018Wait.
2、 Structural description
Dental module brush grinderIt has a desktop appearance and is suitable for placement on a workbench that is close to the actual operating height. Eight brushing and grinding units are arranged in parallel on the operating surface of the equipment, and the open working state facilitates the tester to observe the testing situation at any time. The main transmission structure and electrical components are located above the brushing and grinding unit, making equipment operation simple and intuitive, and the sample area easy to clean. The operation screen and power switch are located above the operation, which is overall beautiful and elegant. The frame is welded with structural square tubes, and the panels are made of thickened stainless steel, which is sturdy and durable.
3、 Main technical parameters
1Work Unit:8A module unit
2Working power supply:220V AC,50/60HZ
3Equipment power:500W
4Structural materials: stainless steel and sliding ball bearings
5Test pressure range:10g-2000gadjustable
6Work pressure value: ≤500gf
7Test pressure sensitivity:2.0±0.05Mv/v
8Brushing frequency:10-200time/Adjustable division
9Accuracy:0.1g
10Working hours:0.5-900minConfigurable
11Display screen size:7Inch LCD screen (capable of real-time display and monitoring of pressure values of various working units)
12Brush grinding stroke amount:50±1mm
13Dental module area:73mmx22mmx10mm(Customizable)
14Appearance size approximately:950mmx650mmx550mm
15Sensitivity:2.0±0.05mv/v(superior to0.03%High precision)
16、Dynamic pressure value:<30gf(Measurable and Calibratable)
17Number of sample cups for testing solution:8a
18Net weight of equipment (approximately):55kg
Note: The digital pressure values of each working unit of this equipment can be measured