Welcome Customer !

Membership

Help

Zhejiang Kailida Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Zhejiang Kailida Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Yongjia Wuniu Industrial Zone, Wenzhou, Zhejiang

Contact Now

Three phase simple multifunctional electric energy meter

NegotiableUpdate on 03/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Three phase multifunctional electric meter, three-phase smart electric meter, three-phase three wire multifunctional electric meter

Product Details

DT (S) SD825 three-phase simple multifunctional energy meter (hereinafter referred to as the instrument) is an indoor three-phase energy meter with high accuracy and feasibility.

2. This instrument adopts internationally advanced ultra-low power large-scale integrated circuit technology and SMT advanced process. The key components are selected from international brands and long-life devices, which improves the reliability of the product and extends its service life.

3. LCD is used to measure active and reactive energy, and the electricity can be read through infrared communication, which is intuitive and easy to use.

4. The design of this instrument complies with the relevant technical requirements for three-phase static energy meters in standards GB/T 17215-2002 "Level 1 and Level 2 Static AC Active Energy Meters", GB/T 17882-1999 "Level 2 and Level 3 Static AC Reactive Energy Meters", and DL/T 645-1997 "Communication Protocol for Multi functional Energy Meters".

2. Specifications and models

Model and name

accuracy class

Rated voltage (V)

Basic current (A)

DSSD Three phase Three wire Multifunctional Energy Meter

Merit: Level 1.0

Reactive power: Level 2.0

3×100

3×380

3×1.5(6)

3×3(6)

3×5(20)

3×10(40)

3×15(60)

3×20(80)

3×30(100)

DTSD Three phase Four wire Multifunctional Energy Meter

3×57.7/100

3×220/380

3. Main electrical performance indicators

3.1 Basic error: see the table below

Balance load percentage error limit

current

Active Level 1.0

Reactive power level 2.0

Directly connected to the instrument panel

Connected to the instrument through a transformer

Power factor

Error%

Power factor

Error%

0.05Ib≤I<0.1Ib

0.02Ib≤I<0.05Ib

1

±1.5

1

±2.5

0.1Ib≤I≤Imax

0.05Ib≤I≤Imax

1

±1.0

1

±2.0

0.1Ib≤I<0.2Ib

0.05Ib≤I<0.1Ib

0.5L

±1.5

0.5L

±2.5

0.8C

±1.5

0.8C

±2.5

0.2Ib≤I≤Imax

0.1Ib≤I≤Imax

0.5L

±1.0

0.5L

±2.0

0.8C

±1.0

0.8C

±2.0

Percentage error with unbalanced load: ± 2.0 for active 1.0 level meter and ± 3.0 for reactive 2.0 level meter

3.2 Starting current

Connected through a current transformer: the active power of the 1.0 level meter is 0.002Ib.

Direct access: The active power level 1.0 meter is 0.004Ib.

3.3 Submersion

When the voltage circuit is 115% of the rated voltage and the current circuit has no current, the test output of the energy meter should not be

Generate more than one pulse.

3.4 Power consumption

Voltage circuit power consumption ≤ 1.5W/5VA, current circuit power consumption ≤ 2VA

3.5 Operating voltage range

Normal operating voltage: 0.9-1.1 rated voltage

Maximum operating voltage: 0.7-1.2 rated voltage

3.6 Environmental conditions

The standard operating temperature is -25 ℃ to+55 ℃

The maximum working temperature is -40 ℃ to+70 ℃

Annual average relative humidity: ≤ 75%

3.7 Instrument safety performance

The instrument indicators comply with the requirements of GB/T17215-2002 "Level 1 and Level 2 Static AC Active Energy Meters" and GB/T 17882-1999 "Level 2 and Level 3 Static AC Reactive Energy Meters".