Zhejiang Kailida Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Yongjia Wuniu Industrial Zone, Wenzhou, Zhejiang

Contact Now

Three phase electric meter RS485

NegotiableUpdate on 03/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Three phase electric meter, three-phase 485 electric meter, DL/T 645-1997 "Multi functional Meter Communication Protocol"

Product Details

1. Overview
The DTS825/DSS825 three-phase electronic active energy meter complies with the GB/T17215-2002 "Level 1 and Level 2 Static AC Active Energy Meter" standard and is designed and manufactured using advanced SMT production technology. It is used to measure the total active energy of the three phases, has a phase failure indication function, and 485 communication function. The communication protocol complies withDL/T 645-1997Multi functional Table Communication Protocol<<DLT 645-1997.rar>>.
1.2 Product Features
1) The structural design of this product is reasonable and beautiful, with good production process and easy installation and maintenance;
2) Can accurately measure the total active power of three phases, and can use absolute value addition or substitution according to user requirements
Calculate the total power by adding and counting, with phase failure indication function.
3) The circuit design of the electric energy meter is reasonable, all of which adopt industrial products with stable performance and low power consumption
Grade electronic components with excellent anti-interference ability;
4) RS485 communication function can be added according to user requirements, which can remotely read electricity meters
Electricity collection capacity;
5) The electric pulse signal is output in a passive manner and can be used for power meter calibration or meter reading;

Working principle
This electric energy meter adopts a three-phase power supply mode and can work normally under any single-phase power supply situation.
When the electric energy meter is working, the voltage and current are sampled separately by the sampling circuit and sent to the large-scale dedicated integrated circuit for buffering and amplification. Then, they are converted into digital signals by a 16 bit A/D converter. After being processed by a digital multiplier, they are converted into pulses proportional to the magnitude of the electric energy, which drive the meter to accumulate electric energy and drive the pulse indicator light, and output pulses for measurement.
3.1 Specification and Model
model
grade
Reference voltage Un
Calibration current
DSS825
Level 1
level 2
3×100V
3×380V
3×1.5(6)A
3×5(20)A
3×10(40)A
3×15(60)A
3×20(80)A
3×30(100)A
DTS825
3×57.7/100V
3×220/380V
3.2 Basic Error (Balance Load Basic Error Limit)
1
Current value
Power factor (COS φ)
Error limit (%)
Directly connected to the instrument panel
Transformer instrument
Level 1
Level 2
0.05Ib≤I<0.1Ib
0.02In≤I<0.05In
1.0
±1.5
±2.5
0.1Ib≤I<Imax
0.05In≤I<Imax
1.0
±1.0
±2.0
0.1Ib≤I<0.2Ib
0.05In≤I<0.1In
0.5 (Sensory)
±1.5
±2.5
0.8 (capacitive)
±1.5
0.2Ib≤I≤Imax
0.1In≤I≤Imax
0.5 (Sensory)
±1.0
±2.0
0.8 (capacitive)
±1.0
Note: (Ib is the basic current, In is the rated current, Imax is the maximum current)
The percentage error limit for each current point of unbalanced load is ± 2.0 for level 1 and ± 3.0 for level 2.
3.3 Start up
Under the conditions of reference voltage, reference frequency, and power factor of 1.0, instruments with load currents of 0.004Ib (level 1) and 0.005Ib (level 2) should be able to start and continuously measure electrical energy.
3.4 Submersion
When adding 1.15 times the reference voltage to the voltage circuit and there is no current in the current circuit, the test output of the instrument should not generate more than one pulse.
3.5 Operating voltage range
Normal operating voltage: 0.9Un~1.1Un Extreme operating voltage: 0.0Un~1.15Un
3.6 Power consumption
Voltage line power consumption: ≤ 2W (10VA) Current line power consumption: ≤ 4.0VA
3.7 Environmental conditions
Normal operating temperature: -10 ℃ to+45 ℃, working limit temperature: -25 ℃ to+55 ℃,
Storage and transportation temperature: -25 ℃~+70 ℃ Relative humidity: Annual average ≤ 75%
3.8 Dimensions: 228mm × 145mm × 72mm.
3.9 Weight: Approximately 1.5kg.

3.10 Safety performance: The product meets the various indicators and requirements specified in GB/T 17215.321-2008.

4. Main functions
4.1 Energy metering function 2
Energy metering function: active energy metering. Three phase power supply, one or two phases of power outage, measurement accuracy is not affected.
4.2 Output interface: with optocoupler isolation active passive pulse output interface.
4.3 Phase loss indication function