- Phone
-
Address
No. 218 Tangli Road, Chaoyang District, Beijing
Beijing Wowei Technology Co., Ltd
No. 218 Tangli Road, Chaoyang District, Beijing
| model | VTD513 | VTD533 | VTD553 | VTD1003 |
| Experimental force | 0.3Kgf (2.94N), 0.5Kgf (4.90N), 1.0 Kgf (9.8N), 2.0Kgf (19.6N), 2.5Kgf (24.5N), 3.0Kgf (29.4N), 5.0Kgf (49.0N), 10.0Kgf (98.0N) | 0.5Kgf (4.90N), 1.0 Kgf (9.8N), 2.0Kgf (19.6N), 2.5Kgf (24.5N), 3.0Kgf (29.4N), 5.0Kgf (49.0N), 10.0Kgf (98.0N), 15.0Kgf (147N), 20.0Kgf (196N), 30.0Kgf (294N) (optional 0.3Kgf) |
1.0 Kgf (9.8N), 2.0 Kgf (19.6N), 2.5 Kgf (24.5N), 3.0 Kgf (29.4N), 5.0 Kgf (49.0N), 10.0 Kgf (98.0N), 15.0 Kgf (147N), 20.0 Kgf (196N), 30.0 Kgf (294N), 40.0 Kgf (392N), 50.0 Kgf (490N) (Optional 0.5Kgf) |
2.0Kgf (19.6N), 3.0Kgf (29.4N), 5.0Kgf (49.0N), 10.0Kgf (98.0N), 20.0Kgf (196N), 30.0 Kgf (294N), 50.0Kgf (490N), 60Kgf (588N), 80Kgf (784N), 100Kgf (980N) (Force values can be customized) |
| Execution standards | GBT4340.1,GBT4340.2,ASTM_E92 | |||
| Hardness value conversion | According to GB1172-99 and ASTM standards | |||
| Accuracy meets |
JJG260-91, JIS B 7725, JIS B 7734, GB/T3340.2-99 ASTM E-384、ISO 6507-2、ISO4546 |
|||
| Loading method | Auto load/hold/unload | |||
| Rotating tower mechanism |
Automatic and manual Objective lens - indenter - automatic switching and rotation of objective lens The automatic turret provides a fast and simple operation sequence without the need for manual turret rotation to achieve automatic switching of the objective lens pressure head. The high accuracy of the coincidence between the center of the objective lens and the center of the indenter is within 1 micron, ensuring accurate positioning of the sample during compression, and the center position of the objective lens can be adjusted. |
|||
| Minimum testing unit | 0.01μm | |||
| data output | LCD display readout, directly saved to USB flash drive in EXCEL format | |||
| Exchange Scales | HRA、HRB、HRC、HRD、HRF、HV、HK、HBW、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T | |||
| Hardness testing range | 8~2900HV | |||
| Test force application method | Automatic (loading, holding, unloading) | |||
| Measuring eyepiece | Electronic 10 times (15X optional) | |||
| objective lense | Any three objective lenses from 5X, 10X, 20X, and 40X | |||
| Total magnification factor | Choose from three options: 50X, 100X, 200X, 400X | |||
| Test force holding time | 1~99s | |||
| Maximum allowable specimen height | 180mm | |||
| Distance from the center of the pressure head to the outer wall | 160mm | |||
| size | 580*190*700mm | |||
| weight | About 55Kg | |||
| Power Supply | AC220V+5%,50-60Hz | |||