Test plant incubatorTemperature range without humidification: 0~65 ℃ with humidification 10~65 ℃ temperature distribution ± 1 ℃ humidity control range 45%~90% RH content volume 70L 150L 250L.
Test plant incubatorAdvantages:
1. Independent humidification achieves humidity control.
2. LCD 30 segment program control, repeated step by step, step by step operation.
3. Convenient operation, fixed value operation, timed operation, and automatic stop.
4. Use dedicated function keys to achieve temperature setting.
5. Auxiliary menu, realizing over rise alarm, deviation correction, and menu locking. Security over rise alarm, menu lock, over rise prevention, overload protection, power outage protection.
| model | HWS-70B/HWS-70BX | HWS-150B/HWS-150BX | HWS-250B/HWS-250BX | |
| method | forced convection | |||
| Performance | Temperature range for use | No humidification: 0~65 ℃; Humidification: 10~65 ℃ | ||
| temperature resolution | 0.1℃ | |||
| temperature fluctuation | High temperature: ± 0.5 ℃ Low temperature: ± 1 ℃ | |||
| temperature distribution | ±1℃ | |||
| Moisture control range | 45%~90%RH | |||
| Humidity fluctuation | ±5% | |||
| Composition | internal | mirror finish | ||
| exterior | Cold rolled steel plate, surface chemical resistance coating | |||
| Thermal insulation material | polyurethane | |||
| heater | Stainless steel heating tube | |||
| rated power | 0.7KW | 1.0KW | 1.4KW | |
| compressor | Air cooled sealed compressor | |||
| refrigerant | R134A | |||
| Defrosting structure | Type B: Manual; BX type: automatic | |||
| Moisture control method | automatic | |||
| Lead hole | One with an inner diameter of 52mm | |||
| Controlled external power supply | External 1 | |||
| Controller | Temperature control method | 30 segment LCD program | ||
| Temperature setting method | Touch the button to set | |||
| Temperature representation method | Temperature measurement display: LCD upper display; Set temperature display: LCD lower display | |||
| Timer | 0~99.9h * 30 (with timed waiting function) | |||
| Operation function | Fixed value operation, timed operation, automatic stop/scheduled start, program operation | |||
| Program Mode | standard configuration | |||
| Additional features | Type B: Deviation correction, menu button locking, power outage compensation, power outage memory | |||
| BX type: also equipped with over rise prevention device, cumulative timer, circuit self diagnosis, intelligent defrosting | ||||
| sensor | PT100 | |||
| safety device | Type B: Over rise alarm, overload protection; BX type: also equipped with over rise prevention device, cumulative timer, and circuit self diagnosis | |||
| Specifications | Internal dimensions (width * depth * height mm) | 420*350*500 | 500*400*750 | 500*500*950 |
| Dimensions (width * depth * height mm) | 570*560*1073 | 640*620*1260 | 640*710*1463 | |
| Outer packaging dimensions (width * depth * height mm) | 720*720*1120 | 790*770*1380 | 800*870*1580 | |
| internal volume | 70L | 150L | 250L | |
| Partition load-bearing capacity | 15kg | |||
| Number of partition layers | 5th floor | 9th floor | 12th floor | |
| Partition spacing | 60mm | |||
| Rated current of power supply (50/60Hz) | AC220V/2.3A | AC220V/3.6A | AC220V/5.5A | |
| Net weight/gross weight kg | 65/83 | 86/106 | 100/127 | |
| accessory | partition | 2 pieces | ||
| Partition frame | 4 pieces | |||
| Can increase configuration | Partition board, RS485 interface, printer, recorder, external communication, remote control, wireless SMS alarm, USB data storage | |||