UV fluorescence sulfur analyzerThe principle of using ultraviolet fluorescence method for determination. After being introduced into the high-temperature cracking furnace, the sample undergoes cracking oxidation reaction. At a high temperature of around 1050 ℃, the sample is vaporized and undergoes oxidative cracking, where sulfides are quantitatively converted into sulfur dioxide. The reaction gas is carried by the carrier gas, and after passing through a membrane dryer to remove its moisture, it enters the reaction chamber. Sulfur dioxide (sulfur content) is exposed to specific wavelengths of ultraviolet radiation, absorbing this radiation to redirect some electrons to high-energy orbitals. Once electrons return to their original orbits, excess energy is released in the form of light and detected by a photomultiplier tube at a specific wavelength. The emitted fluorescence is specific to sulfur and proportional to the sulfur content in the original sample. After amplification by a microcurrent amplifier and computer data processing, it can be converted into an electrical signal proportional to the intensity of light. By measuring its size, the sulfur content of the corresponding sample can be calculated.TS-3000 UV Fluorescence Sulfur Analyzer
UV fluorescence sulfur analyzerScope of application: Suitable for determining the total sulfur content in crude oil, distillate oil, petroleum gas, plastics, petrochemical products, food, etc.
Compliant with standards: Compliant with ASTM D5453, SH/T 0689 and other standards.
Measurement range: 0.2mg/L to 10000mg/L
Measurable sample states: solid, liquid, gas (with corresponding injector).
PMT high voltage range: DC400V~900V, set the required value through the operating system based on the measured concentration.
Temperature range: Room temperature to 1100 ℃
Temperature control accuracy: ± 3 ℃
重复性: 0.2mg/L≤X<1.0mg/L,≤±0.1mg/L
1.0mg/L≤X<100mg/L,Cv≤10%
100mg/L≤X≤10000mg/L,Cv≤5%
Instrument completeness: mainframe, cracking furnace, automatic sampler, computer (including operating software), printer, etc.
Windows operating platform, human-machine dialogue, convenient operation.
Microcurrent detection adopts domestic sulfur and nitrogen detectors, which make the instrument highly sensitive, low-noise, wide linear range, and strong anti-interference ability. It is a total sulfur content analyzer in China.
High voltage can be adjusted arbitrarily, and single point calibration can be adopted for standard sample calibration, which is convenient, fast, and accurate.
TS-3000 UV Fluorescence Sulfur Analyzer