- Phone
-
Address
2nd Floor, Building 18, Wujing Science and Technology Park, 4999 Hongmei South Road, Minhang District, Shanghai
Shanghai Zhiqin Environmental Technology Co., Ltd
2nd Floor, Building 18, Wujing Science and Technology Park, 4999 Hongmei South Road, Minhang District, Shanghai
feature
TCR series temperature resistance coefficient testing systemCapable of testing any resistance condition under high temperature, low temperature, and high/low temperature variations
1. Equipped with automatic detection function to automatically eliminate test sequences
2. There are two modes to choose from: fixed current and automatic current adjustment
3. Automatic calculation of resistance change rate function, threshold judgment can be set
4. Fully intelligent testing, automatic data storage, no need for manual intervention
5. The system comes with a built-in UPS to ensure that external power outages do not affect testing and data storage
6. Chinese software operation interface, well customized human-machine operation interface
TCR series temperature resistance coefficient testing systemSuitable for testing silver paste materials and resistance testing after screen printing. Equipped with a flying needle testing platform, it can test the resistance of finished products
model |
TCR |
||
performance |
test channel |
120~384CH, Define the number of channels based on the specific testing fixture |
|
test scope |
1mΩ~10MΩ |
||
test method |
four-wire system |
||
Resistance measurement accuracy |
±0.05%RD±5uΩ |
||
Resistance testing speed |
1秒/通道 |
||
test instrument |
6220+2182 |
||
Test time |
1~9999 hours |
||
UPS protection time |
30 minutes |
||
|
warm degree |
scope |
-70 ℃~180 ℃, customizable high temperature up to 200 ℃ |
|
Test area volume |
100L~150L |
||
Rising rate (non-linear) |
Standard configuration with an average speed of 2 ℃/min throughout the entire process; The average temperature throughout the process is 5 ℃/min, 10 ℃/min, 15 ℃/min, and 20 ℃/min. Optional options are available |
||
Decline rate (non-linear) |
Standard configuration with an average speed of 1 ℃/min throughout the entire process; The average temperature throughout the process is 5 ℃/min, 10 ℃/min, 15 ℃/min, and 20 ℃/min. Optional options are available |
||
test data |
Real time display, automatic calculation of resistance change rate and other parameters, data automatically saved in file format in the database |
||
Test cable |
High and low temperature resistant silver plated copper wire |
||
test fixture |
Adopting standard gold finger connectors and installation versions, with numbered indications |
||
Permissible environmental conditions |
+10~35℃ |
||
Power Specifications |
220V AC 1 ø 50/60Hz, 380V AC 50/60Hz (three-phase four wire+protective ground wire) |
||