TA DIL 832 expansion meter from the United States
TA DIL 832 expansion meter from the United States
With the following impressive technologies and features, DIL 832 has become an ideal tool for all R&D laboratories to perform mechanical and dimensional characterization: TA instrument removes True Differential ™ Technology, obtaining proprietary 1 nm resolution optical encoders, a series of new dynamic heating furnaces, and a new linear sample loading motor. Create a horizontal push rod expander with excellent performance in the industry, unaffected by the tested application or material.
Within the total measurement range of 5000 μ m, the linear motor can ensure a sample loading force of 0.01 to 1.00 N, with a force resolution of 0.01 N and linearity better than 0.01 N.
Obtaining a proprietary new incremental optical encoder reduces the true resolution of length measurement to 1 nm, reaching an excellent level compared to similar products. Support measuring short samples while maintaining excellent ∆ L resolution.
The newly designed measuring head housing and active electrical thermal stability ensure that the detection core has the stability of deletion. DIL 832 removes True Differential from TA instrument ™ Combining technology with TA instrument heating furnace design to provide industry standard 0.01 x 10-6K-1CTE accuracy.
DIL 832 automatically records the initial sample length, supporting deletion/extensive sample lengths of 25 mm and deletion/extensive diameters of 6 mm.
The water-cooled furnace provides dynamic temperature programming function, with a deletion/extensive heating rate of 50 K/minute. It only takes 13 minutes to cool from 1000 ° C to room temperature, which is only 1/15 of similar instruments.
Integrated electronic components provide network connectivity, while integrated touch screens allow users to directly perform multiple functions in the instrument, displaying measurement parameters and test completion time in real-time.
| Expansion instrument type | Expansion instrument type | |
| Sample size, length/diameter | 0 to 25 mm/12 mm | |
| Sample holder material: | Fused silica or, Al2O3 | |
| Contact force: | 0.01 – 1.0 N | |
| Range of length variation: | 5000 µm | |
| Resolution ∆ L: | 1 nm, 0.05°C | |
| Accuracy (α): | 0.01 x 10-6K-1 | |
| Gas environment: | Vacuum, inert gas, air Gas device with mass flow controller and vacuum device (optional) |
|
| Temperature range: | RT – 1100°C RT – 1500°C RT – 1700°C |
|
| heating rate | 50°K/min | |
| Cooling rate | 1100 ° C – RT: Short duration of 13 minutes 1500 ° C – RT: less than one hour 1700 ° C – RT: approximately one hour |
|