E-mail
dan600507@163.com
-
Phone
19916557244
-
Address
Room 1706, International Trade Building, No. 55 Keelung Road, Waigaoqiao Free Trade Zone, Shanghai
Langbo China Technical Service Center, Germany
dan600507@163.com
19916557244
Room 1706, International Trade Building, No. 55 Keelung Road, Waigaoqiao Free Trade Zone, Shanghai
Chinese LABOM BiochemistryDetailed introduction of temperature switch
Chinese LABOM Biochemical Temperature Switch/Temperature Transmitter, MiniTherm GS is used for monitoring and process control of surface temperature of tanks and pipelines, particularly suitable for sanitary applications
Application fields of LABOM biochemical temperature switch in China
Food industry
Pharmaceutical industry
Biochemical technology
Optional equipment for Chinese LABOM biochemical temperature switch
Parameter adjustment can be made through COMLINE. S PC software
Two floating switch contacts
The switch contact has a high switching current (1A)
Verify that the certificate meets the requirements
Material certificate according to DIN EN 10204-3.1
Calibration certificate according to DIN EN 10204-3.1
Surface smoothness grade
Electric polishing of liquid receiving components
Characteristics of Chinese LABOM Biochemical Temperature Switch
Supply - LABOM Biochemical Temperature Switch from Germany
Supply - LABOM Biochemical Temperature Switch from Germany
Multi functional temperature transmitter/temperature switch
Resistance thermometer with protective sleeve for measuring tank and pipeline
■ Compact and compact design
High precision and fast response
Sanitary design and structural design comply with EHEDG standards
Process connection is suitable for food/pharmaceutical/biochemical applications
4-digit LED display, capable of 180 ° mirror view display
The indicator module can rotate freely up to 300 °
Process temperature range -50 ℃ to+2050 ℃
Output signal 4... 20 mA, two-wire technology
■ Convenient on-site programming
The transmitter and switch outputs are electrically isolated
Technical data of LABOM biochemical temperature switch in China
Shell design
Design seamless sanitary casing and fully encapsulated electronic components
Material: Stainless steel 1.4301 (304),
Display module Macrolon
Protection level IP67, compliant with DIN EN 60529
Electrical connections Circular connector M12, 4-pin
Circular connector M12, 8-pin 1
When equipped with a switch option, it is necessary to
Temperature measuring element
Measure the insertion of 6mm stainless steel material,
Optional: Reduce the diameter of the probe end? 4 mm
Please refer to the selection table for the insertion length
Measurement of resistance Pt100, three wire thin layer technology
Response time according to DIN EN 60751, test medium is water (without transmitter)
T 90 = 5.5 s;
Reduced end diameter? 4 mm:
T 90 = 4.5 s
temperature range
Environmental temperature -20 ℃... 85 ℃
Process temperature -40 ℃... 150 ℃
Allowable storage temperature -40 ℃... 100 ℃
Other temperature ranges are based on customer requirements.
process connection
The different process connections are shown in the selection table.
The maximum work pressure is 16 bar, except
VARIVENT D=68 Code A1512zui up to 10 bar
Sanitary Design
Surface smoothness Ra ≤ 0.8 μ m
Welding<1.6 μ m
Electropolishing does not include gaskets according to user requirements! Other process connection forms are based on user requirements.
instruction
Type 4-digit number, red 7-segment LED on-site indication
Digital display height 8.5 mm
Numbers with resolutions ranging from 9999 to 9999
The direction can be rotated 300 degrees, and when installed in reverse,
Digital display can be reversed 180 °
Indication - Measurement Value
-Measurement unit
-Operation menu
The decimal point is automatically set according to the measurement range/unit
Zui can be set in three different positions,
Or manually set the position of 0... 3
By manually pressing the button or pressing the cycle (the cycle can be set),
Temperature and units can be displayed alternately on the screen
Measurement units ℃, ℉, K, mA can be set
S
measurement rangeThe parameters can be set at -40...+150 ℃,
Zui small range span 25 K
output signal
Output signal 4... 20 mA, two-wire technology to load communication signal
Response characteristic temperature linearity
Current range 3.8... 20.5 A
Resolution 0.3 A
Current limit ≤ 21 mA
Load ≤ (U-12V)/21mA (Ohm)
Switch delay<5 s
auxiliary power supply
Nominal voltage 24 V DC
Scope of work: 12... 30 V DC
Integrated voltage reverse protection
Accuracy
Transmitter
Linear error<0.2 K or 0.08% measurement range
Temperature effect Tu 1<0.1%/10 K
Auxiliary power supply impact<0.005% measurement range
Load impact ≤± 0.02%/100 Ω
1 Tu=ambient temperature
Switch output (optional)
Type: Two contact switch with common grounding point (low side, NPN)
Switch capacity 30V DC/200 mA, short circuit protection selection 1A
The switch status is open or closed, programmable
Cut off the circuit of the device: Open the contact
Switching mode: Window/hysteresis, programmable
Set the scope within a limited range
Lag within a limited range, with a measurement range that is 0.5% smaller than the maximum
Switch delay 0.0... 999.9 s
Repetitive accuracy 0.2% full-scale value
Current isolation is used to isolate between the transmission and switch outputs
Switching cycle>10 million times
Voltage drop<1 V (<1.5 V, current>100 mA)
Output status indicator red LED, output according to the switch
Parameter adjustment three key parameter adjustment or PC parameter adjustment
Parameter adjustment
The following parameters can be set through COMLINE. S software and the 3 keys on the dial

wiring diagram

Size chart



Selection Table - Please indicate other characteristics of models not listed-