E-mail
xqwfbj@163.com
-
Phone
13701143136
-
Address
No. 40 Xueyuan Road, Haidian District, Beijing
Beijing Xianzhuo Weifeng Technology Development Company
xqwfbj@163.com
13701143136
No. 40 Xueyuan Road, Haidian District, Beijing
CASSulfide analyzer
• Professional sulfide determination
Suitable for liquid and solid samples
• Simple and efficient operation
High precision and accuracy
• Compliant with national standards
Sulfide analyzerprinciple
Sulfide acidification - blowing (aeration) - absorption principle, cyclic absorption method.

1-Release agent bottle; 2-Release agent pipeline; 3-Release agent addition module; 4- Sample bottle;
5-Circulating gas path 1; 6-Absorption bottle; 7-Circulating gas path 2; 8-cycle module; 9-Circulating gas path 3
Simple and efficient
Batch sample cycle absorption for 5 minutes, processing capacity>300 samples/day
• Easy to operate, two key operation
Automatic acid addition to avoid the loss of hydrogen sulfide during manual acid addition process
• Headspace volume<300mL, accelerate circulation blowing and absorption, reduce residue
Safe and energy-saving
The system is sealed and non-volatile, without the need for a fume hood
• No heating required, energy-saving and environmentally friendly
No need for nitrogen, safe and energy-saving
Accurate and reliable
• High fold enrichment, low detection limit
• High measurement repeatability, in compliance with relevant standard requirements
High measurement reproducibility and long-term stable data
carefully designed
Carefully selected materials, inert materials reduce adsorption, reduce cross contamination, and are easy to clean
Scientific design, durable and reliable
meet the standard
GB/T 16489-1996 "Water quality - Determination of sulfides - Methylene blue spectrophotometric method"
GB/T 5750.5-2006 "Standard Test Methods for Drinking Water"
GB 17378.4-2007 "Marine Monitoring Code Part 4: Analysis of Seawater"
HJ 833-2017 "Determination of Sulfides in Soil and Sediments - Methylene Blue spectrophotometric method"
GB 17378.5-2007 "Marine Monitoring Code Part 5: Analysis of Sulfides in Sediments"
Technical Specifications:
Cycle absorption time |
5 minutes per batch |
Acid addition method |
Automatic quantitative acid addition (peristaltic pump) |
number of channels |
6通道 |
Sample bottle |
Available in volumes of 100 and 250mL, transparent and brown |
absorption bottle |
Available in volumes of 100 and 50mL, transparent and brown |
concentration multiple |
≤ 50 times |
sample size |
液体≤250mL |
Solid ≤ 50g | |
detection limit |
0.16 μ g/L (50 fold enrichment) |
recovery rate |
95%~105% |
repetitiveness |
RSD ≤3% |
Overall dimensions |
600mm(L)×600mm(W)×250mm(H) |
temperature and humidity |
10℃~30℃,≤80%RH |
power supply voltage |
220V/50Hz,75W(Max) |
Application field
Marine environment, soil environment, drinking water, domestic sewage, drainage, petrochemical industry