Welcome Customer !

Membership

Help

Tianjin Deshang Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Tianjin Deshang Technology Co., Ltd

  • E-mail

    sales@brillante.com.cn

  • Phone

  • Address

    2-1501 Henghua Building, No. 501 Dagu South Road, Hexi District, Tianjin City

Contact Now

Stack testing workstation

NegotiableUpdate on 12/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The fuel cell testing platform mainly consists of fuel cell stack, cell support structure, flow control system, temperature control system, measurement and control system, and ancillary equipment.

Product Details

a. Electronic load module

-9kW, 12kW (water-cooled type)

-600A,1000A

-60V,120V,400V

b. Floor standing chassis

-Assemble the box

-Including all necessary hardware and connection accessories

-Keyboard and monitor stand

-Power supply: three-phase 220VAC or 380VAC, Max75A-1100 (W) × 1800 (D) × 2000 (H) mm

c. Mass flow controller

-阳极: H2, N2, Max150 SLPM

-Cathode: air, N2, Max500 SLPM

d. Humidifier bottle device

-Bubble or membrane humidification type

-Temperature control, water temperature reading

-High temperature float level switch

-Wet and bypass modes

e. Automatic water injection

-Deionized water is automatically injected into the humidifier

f. Heating and cooling water circulation of fuel cell stack

-Pool 50L

-Heating (up to 95 ℃) and cooling system

-Automatic control of circulating flow rate

-Monitoring of water conductivity

g. Automatic water filtration system

-Deionized water filtration system

-Automated production

h. Automatic back pressure control and monitoring

-Max3.5bar control

-Pressure ratio control

-Low pressure drop of 0-2kPa at Max flow rate

-Differential pressure control

-Pressure control of fuel cell inlet and outlet (H2, air)

i. Preheater (online heater)

-Flexible SUS stainless steel tube, anode 1/2 ', cathode 3/4'

-Direct gas temperature control

j. Water trap

-Automatic discharge of condensate water

-Radiators and cooling fans

k. Operating software

-Based on LabVIEW software

-Various fuel cell operation functions

-Real time data display and data acquisition card DAQ

-Automatic protocol testing

-Process tracking (load tracking)

-Customer customization

Optional items

1. Battery voltage monitoring

-± 5V/individual battery

-Single cell battery channel selection

2. Single channel or multi-channel AC impedance testing system

-Load combination type, high-frequency resistor HFR combined with IV test

-Frequency range 10mHz~10kHz

-Combination of operating software and fuel cell software

(HFR, IR resistance, Ohmic resistance, AC impedance EIS)

-Multi channel

3. Stack discharge

-1-2kW resistor relay