Welcome Customer !

Membership

Help

Guangzhou Zijing Purification Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Guangzhou Zijing Purification Equipment Co., Ltd

  • E-mail

    52047082@qq.com

  • Phone

    15989000960

  • Address

    Website of No. 18-20 Longcheng Development Zone, Dalong Village, Panyu District, Guangzhou City

Contact Now

Square horizontal flow ultra clean workbench

NegotiableUpdate on 12/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Square horizontal flow ultra clean worktable, also known as square horizontal flow clean worktable and square horizontal flow purification worktable, is a new type of ultra clean worktable developed by our company. It has the characteristics of large operating area, high cleanliness level, and is also a highly versatile local clean worktable, suitable for high cleanliness production workshops. It can be connected in series for control and use

Product Details

Square horizontal flow ultra clean workbench, also known as square horizontal flow clean workbench and square horizontal flow purification workbenchThe square horizontal flow ultra clean worktable is a new type of ultra clean worktable developed by our company. It has the characteristics of large operating area and high cleanliness level. At the same time, it is also a highly versatile local clean worktable, suitable for high cleanliness production workshops, and can be controlled in series for use.

方形水平流超净工作台产品正面图

Square horizontal flow ultra clean workbench | Clean workbench | Purification workbench optional accessories, according to the actual needs of different customers, the optional accessories are as follows:
1. UV sterilization lamp; 2. Static electricity removal equipment; 3. Stainless steel orifice plate tabletop; 4. ULPA ultra efficient filter; 5. Digital circuit control system.

Characteristics of Square Horizontal Flow Ultra Clean Workbench
1. Adopting an ultra-thin high-efficiency filter without partitions, the size of the static pressure box is minimized, and equipped with a stainless steel tabletop and glass side baffle, making the entire workspace appear spacious and bright;

2. Convenient detachable high air volume pre filtration primary filter, better protecting the high-efficiency filter and ensuring wind speed;

3. Adopting an adjustable air volume supply system and gear speed regulation to ensure ideal wind speed in the working area;

4. Horizontal flow pattern, open desktop, easy to operate.

Applicable fields of square horizontal flow ultra clean workbench
Microelectronics, laboratory, national defense, precision instruments, meters, biopharmaceuticals, optoelectronics industry, hard disk manufacturing field, etc.If there is a choice(Vertical flow ultra clean workbench)Please refer!方形水平流超净工作台产品侧面图

Configuration instructions for square horizontal flow ultra clean workbench
1. The fan adopts German EBM direct drive high-efficiency centrifugal fan, which has the characteristics of long life, low noise, maintenance free, low vibration, and stepless speed regulation. The speed regulation performance of the fan is stable, and the working life is up to 50000 hours or more.

2. Equipped with a differential pressure gauge from the United States, it clearly indicates the pressure difference on both sides of the high-efficiency filter, the initial efficiency filter, and promptly reminds to replace the high-efficiency filter.

3. Before leaving the factory, each product is strictly inspected according to the US Federal Standard 209E, with a high level of reliability.

Square horizontal flow ultra clean workbench material: The box body is made of cold-rolled steel plate sprayed with plastic (or stainless steel), and the tabletop is made of sandblasted stainless steel;

方形水平流超净工作台产品结构细节Specifications, dimensions, and parameters of square horizontal flow ultra clean workbench:
Single person level hundred level workbench, small double person level hundred level workbench, large double person level hundred level workbench
Dimensions (W × D × H) 960 × 780 × 1581200 × 820 × 1580, 1500 × 900 × 1580

Work area size (W × D × H) 930 × 600 × 650, 1170 × 600 × 650, 1470 × 600 × 650

Cleanliness level: Level 100 @ 0.3 μ m (Federal Standard)

Rated air volume: 1200m3/h, 1800m3/h, 2300m3/h

Average wind speed: 0.3-0.6m/s

Air filter filtration efficiency: 99.99% @ 0.3 μ m or above H13-H14

Illumination:>=300lx

Power consumption: 280W, 405W, 490W

Noise:<=65dB<=65dB<=65dB

LED light specifications and quantities: 9W × 1, 13W × 1, 18W × 1

Material: The box body is made of cold-rolled steel plate sprayed with plastic (or stainless steel), and the tabletop is made of sandblasted stainless steel

Power supply 220V/50Hz

超净工作台高效过滤器

The maintenance of ultra clean workbench | clean workbench | purification workbench is very important, as it directly affects production:
1. It is necessary to check and confirm whether the caster brake has been released. After fixing the position of the ultra clean workbench, the brake should be applied.

2. Regularly remove and clean the primary filter, with a cleaning cycle of generally 3-6 months.

3. To avoid deformation of the ultra clean workbench or raceway, and to prevent heavy objects or forklifts from colliding with the ultra clean workbench frame, so as not to damage the ultra clean workbench, only one turnover box can be placed on each layer of the fluent frame of a regular ultra clean workbench, and the weight of each turnover box on the ultra clean workbench frame should not exceed 20 kilograms as much as possible.

4. Check if the bolts on the ultra clean workbench are tightened.

超净工作台初效过滤器

Ultra clean workbench | Clean workbench | Purification workbench Safety precautions:
(1) Basic safety precautions
a、 This product is suitable for indoor use, please do not use it outdoors. Please do not place it near high-speed dust sources and seismic sources.

b、 Please do not use volatile oils, diluents, corrosive solvents, etc. to wipe the box to avoid damaging the paint layer or causing discoloration.

C、 Prohibited for use in the following places: low temperature, high temperature, high humidity, condensation, high dust, as well as places with oil fume and mist.

d、 Do not impact the glass to avoid causing harm to the human body.

e、 Ensure maintenance space and facilitate the replacement of fans and filters, as well as the maintenance of electrical components and circuits.
(2) Electrical safety matters
a、 First, place the product in place before wiring and connecting the power supply to avoid personal injury.

b、 Please confirm if the rated voltage and frequency of this product match the parameters of the input power supply to avoid damaging electrical components and causing fires.

c、 When using the equipment, professionals must perform reliable grounding operations on the grounding terminals of the equipment. Please make sure to connect the power plug to a socket with a protective grounding wire and use a power supply with a leakage protection device to ensure the safe use of the equipment.
d、 Do not repeatedly operate the power switch within one minute to avoid damaging electrical components due to frequent actions.

e、 This product does not have riot control capability and is strictly prohibited from use in flammable and explosive environments.

f、 Please do not touch the electrical components inside the product. When it is necessary to touch, please unplug the power plug first.

g、 It is strictly prohibited to modify this product to avoid accidents such as electric shock and fire.

h、 Please do not place heavy objects on the power cord to avoid ignition or electric shock caused by damage to the outer skin of the power cord.

i、 When not in use for a long time, please unplug the power plug from the socket.

j、 When there is an abnormal situation, please stop running, cut off the power, and then contact the distributor or our company of this product.

(3) Operational safety precautions
a、 Under normal atmospheric conditions, the insulation resistance between the power input terminal of this product and the casing or exposed conductive parts should be greater than 20MQ, and the insulation resistance value after humidity testing should be greater than 2MQ.

b、 When replacing filters or performing maintenance work, if a sterilization lamp is used, the workbench must be sterilized before proceeding.

c、 If any abnormalities are found during work or maintenance, the power should be cut off in a timely manner, and relevant personnel should be notified for maintenance to avoid accidental start-up and personal injury.

The specifications and dimensions of the square horizontal flow ultra clean workbench can be customized according to any needs, and we can provide you with thoughtful products.