Spot sales of HYDAC sensors, Hedec transmitters, relays, and the full range-Shanghai Nianci Machinery Equipment Co., LtdLong term advantages for selling Germany's Hedec HYDAC main products: HYDAC pressure switch, HYDAC pressure sensor, HYDAC pressure relay, HYDAC solenoid valve, HYDAC filter element, HYDAC solenoid valve, HYDAC pressure valve, HYDAC proportional valve
Hedeke EDS8446 series pressure switchThe main categories include normally open and normally closed. The main features are:
1. Adopting the British style pipe thread quick connector or copper pipe welding installation structure, the installation is flexible, easy to use, and does not require special installation and fixation.
2. The plug-in wire type connection can be freely selected by users.
3. Sealed stainless steel sensor is safe and reliable.
4. Manufacturing can be carried out within the pressure range according to the pressure value selected by the user.
Hedeke HYDAC pressure switchOperation Method
1. Method for setting control pressure
(1) Short press the ON/OFF button to turn off the running indicator light and the pressure control system.
(2) Set control upper/lower limit
Short press the SET button once to enter the lower limit setting state (corresponding to the lower limit indicator light on), set the value through (▲) (▼), and after setting the lower limit, short press the SET button to enter the upper limit setting. The setting method is the same as above.
(3) After the setting is completed, press the SET button to automatically save the set values to the computer chip (if there is no button operation within 5 seconds after parameter modification, the current parameter settings will be automatically saved).
(4) Press the ON/OFF button again (corresponding to the running indicator light on), and the motor will start working.
2. Unit switching method: Short press the ON/OFF operation button to turn off the operation indicator light, and short press the increase button (▲) to switch units between MPa, Kg/cm, and PSI at will. After setting, turn on the running indicator light.
3. Zero position reset function: Short press the ON/OFF operation button to turn off the operation indicator light, and long press the decrease button (▼) for 5 seconds to reset the current pressure value and correct the zero position error. After setting, turn on the running indicator light. (When using this function, the pressure switch must not apply pressure.)
System Function Mode
Press and hold the SET button for 3 seconds to enter the system settings, then press and hold the SET button briefly to display the following functional modes in sequence.
After setting all functional modes, press the (ON/OFF) run button to automatically store the set values in the computer chip.
Hedeke HYDAC pressure switchFunction Mode Function Explanation Function Setting Method
Power on self-test R001/R000 off/on function enabled: The relay remains closed for 1 minute after power on, and even if the pressure exceeds the upper limit set value during this period, the relay will not open. Prevent the motor from starting frequently due to sudden changes in pressure inside the pipe when the motor is just started. After entering the system settings, use the increase key (▲)/decrease key (▼) to turn on or off the function, and underline it as the default function.
Automatic pressure detection S000/S001 on/off function activated: After the relay is closed and no pressure change is detected for 3 minutes, the controller will automatically disconnect the relay and display an alarm with "E-1" on the screen. To avoid motor idling caused by the measured pressure not reaching the set upper limit value for a long time due to water source drainage, pipeline leakage, etc. After entering the system settings, use the increase key (▲)/decrease key (▼) to turn on or off the function.
Overpressure self-test N001/N000 off/on function activated: When the pressure exceeds (upper limit+0.1MPa), the relay is disconnected, and the screen alarm displays "E-2". When the pressure falls below (upper limit+0.1MPa) again, the alarm is cancelled and the controller resumes operation. Remind customers that there is pressure exceeding the control limit in the control system. Please check if there are any abnormalities in the system. After entering the system settings, use the increase key (▲)/decrease key (▼) to turn on or off the function.
Control delay H001/H000 off/on function enabled: When the pressure reaches the action point, the controller does not immediately act, and the action is delayed. The time for the delayed action can be set. Setting a control delay can prevent the motor from frequently starting and damaging due to unstable pressure inside the pipe. After switching H001 to H000, press the SET key briefly to display '0010'. Use the (▲) (▼) keys to change this value in seconds, which defaults to 10 seconds. Press the SET key to save the settings and pop up.
Parameter protection P001/P000 off/on function enabled: Press any key other than the (ON/OFF) run key, and the screen will display "----". At this time, a password is required to set parameters such as upper and lower limits. Protect the parameters set by engineering personnel from being modified. When '---' is displayed, enter the password through the (▲) key, shift the SET key, and the password is' 1111 '. After short pressing the SET key to confirm, parameter settings can be made. After the system is restarted, it automatically enters the password protection function.
※ Function definition: "* 001" (mode off), "* 000" (mode on), underlined to indicate factory default mode
Hedeke HYDAC pressure switchmain purpose
The Hedeke EDS8446 series pressure switches are divided into two categories: mechanical and electronic. Mechanical pressure switches are further divided into various types, while electronic intelligent pressure control switches are a new type of pressure control product developed by Shanghai Mingdong Electronic Technology Co., Ltd. This product has the advantages of simple operation, high level of intelligence, fast response, and high precision.
Electronic pressure switches amplify pressure signals through high-precision instrument amplifiers, collect and process data through high-speed MCUs, and compensate with built-in precision sensors. They are high-precision devices that detect pressure and liquid level signals, achieve pressure and liquid level monitoring and control. Widely used in automation systems for measuring gas and liquid pressure in chemical, mechanical, hydrological, electrical, environmental protection, and other fields. Due to its convenient and flexible adjustment, as well as simple installation, it can replace most situations where liquid level switches are used.
Technical parameters of Hedeke EDS8446 series pressure switch
Range: -100Kpa to 200MPa;
Power supply voltage: 12~35V DC (24V DC calibration voltage)/AC 220V AC power supply
Output relay capacity: 380V 3A, 220V 5A, 24V DC 5A, etc
Accuracy: better than various parameters such as 0.0.5% FS and 1% FS
Setting range: Full range range range can be set
Monitoring point: anti fluctuation hysteresis setting.
Operating temperature: -20 ℃ -85 ℃;
Protection level: IP65
Sampling rate: 10 times/second (can be customized according to customer requirements).
Interface thread: M20 * 1.5, G1/4, G1/2, 1/4NPT (can be customized according to customer needs)
Operation instructions
Mingdong digital pressure switch is an intelligent control instrument that integrates pressure measurement, display, and control. It has the characteristics of simple operation, good anti vibration performance, high control accuracy, and long service life.
Hedeke HYDAC pressure switchThe EDS 300 series is a compact electronic pressure switch from HYDAC, integrated with digital display. There are four different output versions to choose from: one switching point, two switching points, the same two variants, and an additional analog output signal A current of 20 mA. In order to achieve optimal adjustment of their respective applications, the device provides additional setting parameters, such as multiple switching delay times and proximity to functional nodes. The main application of the EDS 300 series HYDAC electronic pressure switch is in hydraulic and pneumatic or any other field. This device is very suitable for setting charging functions or pump and compressor control units, as well as for pressure or limit value ship transmission, diesel engines, pumps, and general hydraulic and pneumatic devices.
Integrated pressure sensor with stainless steel diaphragm film DMS
Compact and sturdy design
Accuracy ± 1% FS
3-digit display
Easy to operate through key programming operations
The switch point and reset hysteresis can be independently adjusted for each other
Many useful additional features
EDS 3348-5-0016-000-F1
EDS3316-2-0016-000-F1+ZBE06-02
EDS 344-2-016-000
EDS3446-2-0400-000
EDS3446-2-0400-000
EDS1791-N-400-000
EDS346-3-400-000
EDS 348-5-250-000
EDS 3448-5-0250-000
EDS 3448-5-0040-000
EDS344-2-016-000
EDS344-3-250-000
EDS 3446-1-0100-000
EDS347-4-400-045
EDS344-2-250-000+ZBE02+ZBM300
EDS3448-5-0400-000+ZBE08+ZBM310
EDS344-3-400-000+ZBE03+ZBM300
EDS344-2-400-000+ZBE02+ZBM300
EDS346-2-016-000+ZBE03+ZBM300
EDS348-5-016-000+ZBE08+ZBM14
GermanyHedeke HYDAC pressure switchpressure sensorHYDAC pressure relayHedeke pressure sensorHedeke pressure relay HYDAC pressure switch HYDAC temperature sensor HYDAC temperature switch HYDAC flow sensor, welcome to inquire and orderSpot sales of HYDAC sensors, Hedec transmitters, relays, and the full range-Shanghai Nianci Machinery Equipment Co., Ltd