Split type electromagnetic flowmeter measuring medium: conductive liquids such as sewage, chemical solutions, and tap water. Range: 0.1-15m/s. Output signal: 4-20mA (load resistance: 0-750 Ω)

Product Details

Split type electromagnetic flowmeter

Measurement medium: Conductive liquids such as sewage, chemical solutions, and tap water. Range: 0.1-15m/s. Output signal: 4-20mA (load resistance: 0-750 Ω). Pulse/frequency accuracy level: 0.5, 1.0. Medium temperature: -20~+160 ℃. Explosion proof level: Exd [ib] q Ⅱ CT6 Gb. Protection level: IP67, specially customized up to IP68

The LDG electromagnetic flowmeter is an instrument that measures the volumetric flow rate of conductive liquids based on the working principle of Faraday's law of electromagnetic induction. It is a product of the combination of fluid mechanics and electromagnetics. When a conductor cuts magnetic field lines in a magnetic field, it generates induced electromotive force at both ends. LDG consists of two main parts: flow sensors and converters. The measuring tube is equipped with excitation coils on top and bottom, which generate a magnetic field through the measuring tube after passing through the excitation current. A pair of electrodes are installed on the inner wall of the measuring tube and in contact with the liquid, leading out the induced potential and sending it to the converter. A new type of electromagnetic flowmeter updated on the basis of LDG series electromagnetic flowmeter. New breakthroughs have been made in both appearance and assembly methods, as well as in internal structure: a sharp and angular appearance, quick assembly without welding process, and a rationalized structure with better magnetic field distribution. At the same time, the zinc spraying process has been introduced, which can effectively protect the surface of the electromagnetic flowmeter even in harsh environments and enhance its anti-corrosion performance.

Product features

Small flow rate with high precision, with a lower limit of up to 0.03m/s;

The sensor housing is all made of precision aluminum molds, with beautiful appearance, strong consistency in appearance, tight fit, no welding as a whole, fast loading and unloading, and easy maintenance;

Humanized bottom support design, stable placement;

Thickened lining, curved electrode, with good corrosion resistance and wear resistance, and stronger adaptability to mixed media;

The measuring tube has no flow blocking components, no pressure loss, and low requirements for straight pipe sections. Adaptability to slurry measurement;

Adopting a 16 bit embedded microprocessor, it has fast computing speed, high accuracy, programmable low-frequency rectangular wave magnetization, improved stability of flow measurement, and low power consumption;

Adopting SMD devices and surface mount technology, the circuit reliability is high;

On site, the range can be modified online according to the actual needs of the user to better match with the collection terminal;

The measurement results are independent of physical parameters such as fluid pressure, temperature, density, viscosity, etc;

■ Equipped with digital communication signal outputs such as RS485, RS232, Hart, and Modbus (optional);

■ It has self checking, self diagnosis, self diagnosis, and alarm functions;

There are three integrators inside that can display the forward cumulative amount, reverse cumulative amount, and difference cumulative amount respectively. There is also a power-off clock inside that can record 16 power-off times (optional);

Ultra low EMI switching power supply, suitable for a wide range of power supply voltage changes, with good EMI resistance performance.

Product advantages

project Tongyou Brand other brands
traffic lower limit 0.03m/s (ensuring linear accuracy) 0.3m/s (ensuring linear accuracy)
response time 100ms ≥3S
Strong stable current function have Nothing

Technical Specifications

Execution standards Electromagnetic flowmeter (JB/T 9248-2015)

Nominal meridian (mm)

(Special specifications can be customized)

Pipeline type PTFE lining: DN15-DN2000
Pipeline rubber lining: DN65-DN2000
Pipeline F46 lining: DN4-DN600
Flow direction Positive, negative, net traffic
Range ratio 150:1
Repetitive error ± 0.1% of the measured value
Accuracy level Level 0.5, Level 1.0
Temperature of the measured medium Conventional rubber lining: -20~+60 ℃
High temperature rubber lining: -20~+90 ℃
PTFE lining: -30 to+120 ℃
High temperature PTFE lining: -20 to+160 ℃
Rated working pressure (high pressure can be customized) DN15~DN25≤4.0MPa
DN32~DN300≤1.6MPa
DN350~DN800≤1.0MPa
DN800~DN2000≤0.6MPa
Flow velocity range 0.1-15m/s
Conductivity range The conductivity of the measured fluid is ≥ 20 μ s/cm
Signal output 4-20mA (load resistance 0-750 Ω), pulse/frequency
Communication output RS485, MODBUS protocol, GPRS output
Power supply 220VAC, Allowable deviation of 15% or 24VDC, ripple ≤ 5%
Require the length of the straight pipe section Upstream ≥ 5DN, downstream ≥ 2DN
Connection method The flowmeter and piping are connected by flanges, which comply with the international standard GB/T9119-2000
Protection level IP67, Specially customized up to IP68
Environmental temperature -25~+60℃
Relative humidity 5%~95%
Total power consumption Less than 7.5W