AD2588 is a multi-channel precision testing instrument derived from AD2528. It is a true multi-channel audio analyzer. Equipped with standard 8-channel analog output and 8-channel analog input interfaces, it can achieve up to 8-channel parallel testing. The input channel can withstand a peak voltage of 160V, providing a more convenient and faster solution for simultaneous testing of multi-channel products. Production testing for multi-channel power amplifiers. In addition to the standard analog port, $r $nAD2588 can also be optionally equipped with various modules such as extended DSI0, PDM, HDMI, BTDUO, and digital interfaces.
Opu New Audio Analyzer is a headphone production testing - factory direct sales
AD2528 is a high-performance, multi-channel precision testing instrument in the AD2000 series audio analyzer. It is designed to meet the diverse needs of users in the field of audio testing, with features of efficiency, flexibility, and precision.
AD2528 Audio Analyzer
Multi channel input artifact, retaining stronger expandability

Main functions and features:
Multi channel input/outputAD2528 supports 8 channels of simultaneous input, making it highly suitable for efficient testing on production lines and enabling easy implementation of multi-channel parallel testing. At the same time, the device also provides dual channel analog outputs and digital input/output ports, further enhancing its testing capabilities.
Independent and flexible configurationUsers can flexibly choose extension modules such as DISO, PDM, HDMI, and BT DUO according to their actual needs to meet different testing scenarios and requirements. This flexible configuration makes AD2528 a highly adaptable audio analyzer.
High precision testingThe key performance indicators of the equipment are good, such as residual THD+N of the signal source being below -106dB, ensuring the accuracy and reliability of the testing. Meanwhile, the analog input/output channels have extremely low flatness and residual THD+N, further improving the testing accuracy.
Complete and powerful electroacoustic analyzer functionsAD2528 is equipped with a complete electroacoustic analyzer function, supporting the output and measurement of multiple signal types, such as sine wave, dual frequency sine wave, out of phase sine wave, etc. In addition, the device also supports fast and comprehensive testing, which can be completed within 3 seconds, greatly improving testing efficiency.
Support multiple languages for secondary developmentThe device supports multiple languages such as LabVIEW, VB, C #, Python for secondary development, making it convenient for users to customize and optimize according to their actual needs.
key performance
Residual THD of signal source+N<-106dB
●Simulate 8-channel output, 8-channel input, a true multi-channel audio analyzer
●Support the expansion of complete and powerful electroacoustic analyzer functions through digital interfaces such as BT/HDMI+ARC/I2S/PDM
●Code free, complete comprehensive testing quickly within 3 seconds
●Support secondary development in multiple languages such as LabVIEW, VB, C #, Python, etc
●Automatically generate test reports in various formats
●Support Dolby&DTS digital streaming playback
Product Parameters
| analog output |
| number of channels |
2 channels, balanced/unbalanced |
| signal type |
Sine wave, dual frequency sine wave, out of phase sine wave, sweep signal, noise signal, WAVB file |
| frequency range |
0.1Hz ~ 80.1kHz |
| Frequency accuracy |
Shi 0.0003% |
| output voltage |
Balance 0~21.2Vrms; Unbalanced 0~10.6Vrms |
| Residual THD+N |
<-117dB @ 22kHz BW; <-120dB @ 1kHz 2.0V |
| flatness |
0.01dB (20Hz-20KHz) |
Output impedance
|
平衡40 ohm/100ohm/150ohm/200ohm/600ohm Unbalanced 20ohm/50ohm/75ohm/100ohm/600ohm |
| Analog input |
| number of channels |
8 channels, balanced/unbalanced |
| Maximum input voltage |
160Vpk |
| Voltage measurement flatness |
0.01dB (20Hz~20kHz) |
| Single harmonic analysis |
2 to 10 times |
| Residual input noise |
< 1.3uV @ 20kHz BW |
| Maximum FFT length |
1248k |
| Intermodulation distortion mode |
SMPTE,MOD, DFD |
| Frequency measurement range |
5Hz ~ 90kHz |
| Frequency measurement accuracy |
Shi 0.0003% |
| Phase measurement range |
-90 °~270 °, ± 180 °, 0~360 °°
|
| DC voltage measurement |
support |
| input impedance |
Balance 300ohm/600ohm/200kohm; Unbalanced 300ohm/600ohm/100kohm |
| digital output |
| number of channels |
Single channel (two signals), balanced/unbalanced/fiber optic |
| Non-equilibrium |
Standard SPDIF-EAIJ (IEC60958) |
| balance |
AES-EBU (AES3-1992) |
| optical fiber |
TosLink |
| sampling rate |
22kHz ~ 216kHz |
| Accurate sampling rate |
±0.0003% |
| signal type |
Sine wave, dual frequency sine wave, out of phase sine wave, sweep signal, noise signal, WAVB file |
Signal frequency range
|
0.1Hz ~ 107kHz |
| digital input |
| number of channels |
Single channel (two signals), balanced/unbalanced/fiber optic |
| Non-equilibrium |
Standard SPDIF-EAIJ (IEC60958) |
| balance |
AES-EBU( AES3 - 1992 ) |
| optical fiber |
Toslink |
| Voltage measurement range |
-120dBFs ~ 0dBFs |
| Voltage measurement accuracy |
< 0.0001dB |
| Residual input noise |
< -140dB |
THD+N measurement |
support |
| AUX module |
| AUX specifications |
High level 5V; Low level 0V; Output default low level; Enter default high level |
| PIN pin |
PIN 1-8:INOrOUT 1-8; PIN9:GND |
| Specifications |
| Operating Temperature |
-10°C~40°C |
| Shell material |
metal casing |
| control terminal |
Op New KK Audio Analysis Software |
| rated voltage |
AC:100V~240V |
| rated power |
160VA |
| Size (WXDXH) |
440mmx470mmx135mm |