Spectrophotometer

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
After measuring the ambient light source with the spectrophotometer host, the user's light source data is transmitted to multiple FD-5 or FD-7 working machines, and the same lighting source can be used for color control at multiple locations
Product Details

SpectrophotometerProduct Information

This product is equipped with Konica Minolta's VFS (Virtual Fluorescence Standard) technology, which is a measuring device that meets the printing industry standard * 1 and can evaluate the color of paper containing fluorescent components * 3 under D50 standard light source * 2.

In addition, this product is also equipped with wavelength automatic correction function, which can perform wavelength correction currently maintained by the manufacturer while performing daily whiteboard correction * 4.

*1
Printing industry standard: In the ISO 13655 standard related to color in the printing industry, color evaluation including fluorescence under D50 light source has become a standard.
*2
D50 light source: It is an artificial light source that is close to natural light and used for color measurement.
*3
Fluorescence: It has the property of absorbing ultraviolet light and using this energy to emit light.
*4
Except when installing polarized light filters.

Provide support for color exchange in the global supply chain

By using FD-7SpectrophotometerAfter measuring the ambient light source, the host transmits user light source data to multiple FD-5 or FD-7 workstations, allowing for color control using the same lighting source in multiple locations.
In addition, the automatic wavelength compensation function can reduce instrument errors when using multiple instruments.

main purpose

  • What is the density at the printing site? Color Management
  • Used for printing equipment manufacturers? Fluorescence measurement during the research and development of paper manufacturers
  • Measure printed color blocks
  • CCM for ink input devices

Main features

density

Equipped with printing quality management functions such as color matching and dot enlargement

新功能
As a new industry standard tool that meets the requirements of business printing and packaging printing, it achieves high production efficiency and high quality at low cost.

  • CMYK密度
  • dot area
  • Dot Gain
  • color registration
  • Simple density difference
  • Printing network area ratio
  • Printing plate network increases
  • Spot color density

Equipped with target matching function * 4 * 5

新功能
Display the color difference between the mixed ink and the target color, and adjust the density to make the mixed color closer to the target color. By using the target matching function, ink color adjustment can be made while using a computer or special software.

  • Ideal choice for spot colors or printing colors
  • Display color difference and density values
  • Display the expected density adjustment to make the mixed color closer to the target color and the adjusted expected color difference


Color difference measurement
→ Display the predicted value, and it is expected that the spot color density with a peak at 400nm will be adjusted from 0.86 to 1.16, resulting in a color difference of 0.48

Equipped with functions that comply with various printing standards

新功能
Can perform ISO, JapanColor, GRACoL ®、 SWOP ®、 Qualified/unqualified determination of PSO or user-defined targets. FD-7 and FD-5 are ideal choices for on-site printing quality control.

  • ISO、JapanColor、GRACoL ®、 SWOP ®、 PSO Color Set Download
  • ISO12647 inspection * 4 * 5
    → Can evaluate color difference separately TVI、 Intermediate adjustment extension
  • Grey balance
    → According to G7 ® Assessment method for evaluation

*4
The target color (color set) must be set using the accompanying FD data management software FD-S1w.
*5
The support conversion function can convert target values for evaluation when the support conditions of the sample do not match those of the target.

chroma

Measuring instruments that comply with ISO 13655 measurement condition M1

  • Konica Minolta's proprietary VFS (Virtual Fluorescence Standard) technology enables L * a * b * measurements that comply with ISO 13655 measurement condition M1.
  • FD-7 and FD-5 can perform measurements that comply with all four measurement conditions of ISO 13655. Measurements that comply with M1 can be achieved through Konica Minolta's proprietary VFS (Virtual Fluorescence Standard) technology, while measurements that comply with M0 (CIE light source A) and M2 (illumination with UV cut filters) can also be achieved. In addition, testing in compliance with M3 (M2+polarizing filter) can also be conducted by installing the accompanying polarizing filter.

Can perform scanning measurement (FD-7 only)

  • When the instrument is connected to a computer, manual scanning and measurement can be performed.

Spectral data output (FD-7 only)

  • After connecting to the computer, spectral data under various light sources (380nm~730nm) can be obtained.
  • After connecting to the computer, the spectral radiance data of ambient light (360nm~730nm) can be obtained.
  • Suitable for research and development.

illuminance

Measurable ambient light (FD-7 only)


It can measure the illuminance value * 6 and color temperature of the ambient light for visual evaluation of the light source box or other sources.

The measured ambient light can be registered as a lighting source * 7

When using traditional instruments to measure printing quality on materials containing fluorescent whitening agents, the measurement results often differ significantly from sensory evaluation. This product can calculate the chromaticity value of the tested light source (closer to on-site sensory evaluation), eliminate color differences caused by the influence of fluorescent whitening agents and heterochromatic aberration, ensure that customers obtain ideal colors, and avoid time-consuming and laborious responses to customer complaints.

*6
Simple measurement function, not following JIS standards.
*7
User defined light source

other

Equipped with industry's' automatic wavelength compensation 'function

  • Automatic wavelength compensation * 8 can be performed during whiteboard calibration, making it more convenient.
  • Previously, wavelength compensation could only be performed during manufacturer maintenance. Nowadays, this work can be synchronized during whiteboard calibration, which helps improve the reliability of measurement values.
*8
Except when installing polarizing filters

lightweight

  • The host weighs only about 350g, and even with the target cover installed, the weight is only 430g.
  • Reduced the load on the arm and improved work efficiency during long-term measurements.

Worry free after-sales service for users

  • Our global service centers are always ready to provide you with quick support.
  • The comprehensive service network ensures that your instruments are always in optimal condition.

Standard software

FD data transmission software FD-S1w

  • Import measurement data into Excel ® In the worksheet.
  • Read/register user light source data from/to the instrument.
  • Color set login function (ISO12647 check/target matching)
  • ISO、JapanColor、GRACoL ®、 SWOP ®、 PSO Color Set Download

Sell accessories separately

XY automatic color measurement workbench ColorScout A3+

Using the XY automatic color measurement workbench ColorScout A3+, automatic measurement can be performed.

  • For product information on the XY automatic color measurement workbench ColorScout A3+, please click here

Color management software SpectraMagic ® NX

Using the color management software SpectraMagic ® NX, Not only can evaluation formulas be flexibly set, but reports in any format can also be created.
(Polarizing filters cannot be installed for measurement)

Specification

model FD-7 FD-5
Lighting/Receiving System 45 ° A: 0 ° (circular illumination) * 1
Reflection measurement complies with CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, JIS Z 8722 conditions.
Spectral device Concave grating
wavelength range Spectral reflectance: 380~730 nm;
Spectral radiance: 360~730 nm
Spectral reflectance: 380~730 nm
Measure wavelength interval 10 nm
Half wave width About 10 nm
measurement caliber Ø3.5mm
照明光源 LED
measurement range Density: 0.0D~2.5D; Reflectivity: 0~150%
repetitiveness Density: δ 0.01D
Polarization filter not installed: 0.0D~2.5D, yellow 0.0D~2.0D
Install polarizing filter: 0.0D~2.5D, yellow 0.0D~1.8D
(After whiteboard calibration, measure 30 times at 10 second intervals)
Chromaticity: within 0.05 of δ Δ E00 (without installed polarizing filter)
(After the whiteboard calibration is performed, measure 30 times at 10 second intervals)
Inter device difference Δ E00 within 0.3 (average value of BCRA series II 12 colors, compared to the host measurement value under Konica Minolta standard conditions); No polarizing filter installed)
measure time About 1.4 seconds (single point reflection measurement without polarized light filter installed)
measured value Chromaticity value, color difference value, density value, density difference, dot area, dot enlargement, OK/NG judgment, illuminance, correlated color temperature Chromaticity value, color difference value, density value, density difference, dot area, dot enlargement, OK/NG judgment
Measurement conditions Compliant with ISO 13655 measurement conditions M0 (CIE light source A), M1 (CIE light source D50), M2 (illumination with UV cut filter), and M3 (M2+polarizing filter); User defined light source
light source A、C、D50、ID50、D65、ID65、F2、F6、F7、F8、F9、F10、F11、F12、
User defined light source
Observer 2 ° standard observer, 10 ° standard observer
Color space L*a*b*、L*C*h、Hunter Lab、Yxy、XYZ
colour-difference formula ΔE*ab (CIE 1976)、ΔE*94 (CIE 1994)、ΔE00 (CIE 2000)、ΔE (Hunter)、CMC (l:c)
Paper index WI (ASTM E313-96)、Tint (ASTM E313-96)、ISO 亮度 (ISO 2470-1)、
D65 brightness (ISO 2470-2), fluorescence index
Density standard ISO Status T、ISO Status E、ISO Status A、ISO Status I; DIN16536
Can store data Color target data: 30 records; Density target data: 30 records
display language English, French, German, Spanish, Japanese, Simplified Chinese
Scanning measurement * 2 Scannable measurement color card none
interface USB 2.0
Output data * 2 Display value and spectral reflectance data (FD-7 only); Spectral radiance data (FD-7 only)
power supply Built in rechargeable lithium battery (the new product can measure about 2000 times per charge), power adapter, USB power supply
Dimensions (length x width x height) 70 × 165 × 83mm (for mainframe only); 90 × 172 × 84mm (including target cover)
weight About 350 grams (only for the host); Approximately 430 grams (including target cover)
Temperature/humidity range for use 10~35 ° C; relative humidity 30%~85%, no condensation allowed.
Storage temperature/humidity range 0~45 ° C; relative humidity 0~85%, no condensation allowed.
Standard Accessories White calibration board, target cover, dustproof glass, AC adapter (AC-USB converter), USB cable, soft box, polarizing filter, adapter, FD data transmission software FD-S1w, illumination accessory (FD-7 only), ruler (FD-7 only)
Optional accessories XY automatic color measurement workbench ColorScout A3+, color management software SpectraMagic NX
*1
A wavelength less than 400nm is considered unidirectional illumination.
*2
Computer software must be used.

Function Comparison Overview

*★ is a new feature

FD-7 FD-5
Density measurement function
Density value, density difference
dot area
Dot Gain
color registration
PS version of network area ratio
PS version network expansion
Spot color density
Grey balance
Intermediate adjustment extension
ISO12647 inspection
target matching
Chromaticity measurement function
L*a*b*
L*C*h
Hunter Lab
Yxy
XYZ
⊿ E*ab(CIE1976)
⊿ E*94(CIE1994)
⊿ E00(CIE2000)
⊿ E(Hunter)
CMC(l:c)
Illumination measurement function
Illumination * 3
Correlated color temperature
Paper index
WI/Tint(ASTME313-96)
ISO亮度 (ISO2470-1)
D65 brightness (ISO2470-2)
Fluorescence index
Spectral reflectance coefficient
Spectral data output
memory
Target density value 30 30
Target chromaticity value 30 30
Color set * 2
(ISO12647/Target Matching)
50 50
Other functions
Manual scanning * 3
Automatic functions (density, dot area ratio, chromaticity)
Qualified/unqualified judgment
software
FD-S1w
SpectraMagic NX
ClrChrt
(ColorScout A3+dedicated software)
*1
Below 400nm is unidirectional illumination.
*2
M0, M1, M2, and M3 are the lighting conditions described in ISO 13655 4.2.2 Illumination requirements and measurement conditions.
*3
Simple measurement function, not following JIS standards.
*4
Log in using the standard attachment FD-S1w.
*5
Need to connect to a computer.