Soil seedless density meter

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The soil seedless density meter can measure the wet density, moisture content, dry density, and compaction degree of soil in roads and foundations. $r $n $r $n Main purpose: $r $n $r $n is used for measuring the wet density and moisture content of compacted materials in the following categories: excavation and backfilling construction; Underground passages, basements, and foundations; Backfilling, ditches, and garbage; Roadbed foundation and trench backfilling. Mainly suitable for clay and non cohesive soil, it can also be used for lime or cement modified soil, gravel soil and other soils Main features of $r $n $r $n: $r $n $r $n The user interface is good, and the instrument has both Chinese and English operation interfaces, which are easy to learn and use, suitable for small groups

Product Details

Seedless densitometerSoil seedless density meter Model:HAD-ML3C

Soil density meter, also known asSoil seedless density meterIt can measure the wet density, moisture content, dry density, and compaction degree of soil in roads and foundations.

Main purpose:

Used for measuring the wet density and moisture content of compacted materials in the following categories: excavation and backfilling construction; Underground passages, basements, and foundations; Backfilling, ditches, and garbage; Roadbed foundation and trench backfilling. Mainly suitable for clay and non cohesive soils,It can also be applied to improve soil with lime or cement,Gravel soil and other soils.

Key Features:

The user interface is good, and the instrument has both Chinese and English operation interfaces,Easy to learn and use, suitable for every member of the group to use.

Fast, lightweight, and highly repeatable real-time readings.

peer-to-peerRFtechnology

2-3Minute display of measurement results

Using numbersDDSFrequency synthesis technology,No calibration required,There will be no data drift during use

technical indicators

1)Wet density range:Standard compacted soil site scope

2)Wet density accuracy:Standard testing0-2%

3)Moisture content accuracy:Standard testing0-3%

45High brightness touch screen, clearly visible under strong light

5)Detection depth: depth measurement500mm

(6)Internal data logger can store10000A data(Equipped with large capacityUDisk storage capability200Ten thousand measurement data)

7)Equipped withUSBInterface,UDirectly transfer data to the disk or perform software upgrades within the device

8)Power supply:12V2600mAhRechargeable battery, continuous operation20hour

9)Operating temperature: The ambient temperature is below zero5℃ to 45

10)Volume and weight: Host volume:206mm*120mm*50mm)Weight:0.96kg

Work environment requirements:

Ambient temperature0℃~45

relative humidity<90%RH





Asphalt nucleate density meter, abbreviated as asphalt nucleate meterNon nuclear asphalt density tester

Model:HAD-ML2S

Asphalt nucleate density meter, abbreviated as asphalt nucleate meterThe non nuclear asphalt density tester can quickly test road segregation, low density, and uneven areas. Using electromagnetic induction technology instead of nuclear source radiation method is cost-effective and safe. The instrument calibration is simple, the accuracy is high, the repeatability is good, and the touch screen operation allows users to complete relevant operation training in a short time and master the technology of on-site quality inspection.

Instrument Features

Quickly and accurately conduct density testing on asphalt concrete pavement.

3Data can be read out in seconds.

● Touch screen operation, easier to operate.

No need for core calibration, direct on-site testing.

Higher accuracy and better stability.

Technical Specifications:

1、 On site inspection section

1.Operating temperature: surrounding environment070

Surface height175

storage temperature-2070

2.Detection depth:2cm50cm

3.Temperature Sensor: Measurement Range0350

4.Display measurement items: density, compaction degree, porosity

5.Measurement time: <3second

6.Measurement accuracy:3%

7.Built in measurement calibration function, accurate results can be obtained under various temperature and humidity conditions

2、 Electronic part of the instrument

1.Host size:140×80×57mm

2.Display:5.1Inch high brightness color touch screen

3.Data storage: Internal data records can be stored10000Data with large capacityUDisk storage capability200Ten thousand test data

4.Main power supply:12V 5000mAhLithium battery

5.Battery running time: Can be used continuously20hour




Grain moisture analyzer Automatic moisture analyzer model HAD-8188A


Measurement method: High frequency capacitive (50MHz)
Measurement range: Moisture content: 0~40% (varies depending on sample type) Bulk density: 0~999g/L (reference value)
Measuring 35 varieties including grains
Sample capacity 240mL
Temperature range for use: 0~40 ° C
Accuracy (moisture content): The standard error of the drying method is less than 0.5% (for samples with moisture content below 20%)
Correction function "Weight" through built-in electronic balance (temperature) through thermistor (displacement correction (deviation correction)>-9.9~+9.9%)
Other functions display average, power automatically shuts down
Display digital display (LCD)
Power consumption 240mW
Size and weight: 125 (W) x 205 (D) x 215 (H) mm, 1.3kg
Power supply: 4 1.5V batteries (No. 5 dry batteries)
Attachment
Hopper, automatic hopper, automatic hopper base, cup, brush, 4 1.5V batteries (No. 5 dry battery), instruction manual.


Automatic drug drop point analyzer/drug drop point tester/Vaseline drop point modelHAD-0614


This instrument is suitable for pressing2025th edition of the Chinese Pharmacopoeia0614 Drop Point Measurement Method 2: Electric Heating Block Air Heating Method.The temperature at which the sample in the grease cup drips liquid under specified standard conditions. Suitable for medicinal oils (white Vaseline, yellow Vaseline), some edible waxes (such as palm wax), and oil additives; Lubricating grease, paraffin wax, microcrystalline wax, beeswax (cosmetics), pharmaceutical preparations (such as suppositories), synthetic (resin wax, rosin wax), ointment matrix (hydrocarbon matrix); Emulsion matrix (combination of stearic acid glycerides), other semi-solid matrices (matrix materials for ointments and ointments), suppository matrix (synthetic glycerol fatty acid esters); Cosmetic raw material lipstick matrix (beeswax, wax mixture) and other test articles.This automatic instrument also complies withASTM (D3204, D3461, D3954, D6090), DIN (51920), ISO 4625-2, and the European Pharmacopoeia、 SH0678 standard.

1、 Main functional features

1. Heating furnace structure: The heating furnace includes a heating element, embedded heating plates, and platinum resistance sensors; The middle empty slot is the sample chamber, used to place the sample assembly: including the grease cup clamp, the grease cup for loading the sample, and the lower grease cup slit. There is a light source below the heating element, which emits light through the slit hole of the slit sleeve and shines on the signal sensor. When the sample softens and drips, blocking the light hole, the signal sensor emits a signal and the instrument records the temperature.

2. Sample assembly: with a lipid cup in the middle, used for placing samples; Above is the clamp, used to clamp the upper end of the grease cup and connect the handle; Below is a slit sleeve used to pass light and catch the dripping sample when it reaches the drip point.

3. Inspection of the combination slit sleeve: Enter the main interface, click the "Test" button, set the preset temperature to no more than 40 degrees, click the "Auto Detection" button, and enter the auto testing interface.

4. The sample assembly of the empty fat cup is vertically placed in the sample chamber of the furnace, with the observation port at the lower part of the slit sleeve parallel to the front, and the transparent holes of the furnace body and the slit sleeve parallel to each other, ensuring that the detection hole can be transparent.

5. This instrument is easy to operate, automatically controls temperature, and produces results.

2、 Main technical parameters

1. DripPoint measurement range: from room temperature to300°C

2. Measurement mode: automatic measurement

3. Linear heating rate: 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 (℃/min)

4. Measurement repeatability: ± 1.0 ° C when<200 ° C

At 200 ° C-300 ° C: ± 1.0°C

5. Minimum reading value: 0.1 ° C

6. Instrument weight: 11kg




Portable pollution index automatic detector Automatic portableSDIceremony Model:HAD-SDIZ

1 general want

Monitoring the pollution trend of RO (reverse osmosis) system inlet water has always been an essential task. Usually, people only realize the existence of pollution problems when RO membranes need to be cleaned, but this has already caused serious downtime events and the serious consequence is the need to replace expensive membranes.

Several methods have been adopted in industry to measure the pollution trend of incoming water, such as turbidity, particle count, and pollution index (SDI) measurement. Due to the optical principle used in turbidity and particle counting measurements, non photosensitive colloids and particles cannot be detectedTherefore, it is not possible to directly measure the pollution caused by particles in the suspension, that is, the impact on the membraneThe siltation energy ”It is very difficult to use them to judge pollution trends.

The SDI monitoring method directly measures pollution trends. ASTM D4189 specifies that the SDI measurement method measures the flow of a certain volume of water sample under a certain pressure and standard interval timeThrough microporous filterBlocking rate of 0.45 μ m.

Usually, RO (reverse osmosis) systems are used for SDI of imported raw waterValue less thanIn the case of 1

Operating for several years without any problems; If in the raw water SDIValue less thanIf operated under three circumstances, it will take several months

No need to clean the film. However, in the raw water SDIvalueSystems that operate 3-5 times require frequent cleaning of the membrane, as such systems typically do not function properly. SDIValue greater than5 raw water,

work


It cannot be used for RO inlet water at all. Therefore, accurately and timelymonitoringROWater ingressSDI is very necessary.

However, manual SDI measurement is a tedious and time-consuming task.

The EQSDI pollution index automatic measuring instrument can automatically and continuously monitor

The pollution index of RO inlet water. Operators can quickly and accurately detect reverse osmosis pretreatmentThe effectiveness of the system, therebySDIPollution index detection is no longer cumbersome and greatly reducedThe error of manual monitoring.

EQSDI uses the standard testing method described in ASTM D4189Law, to every5. Calculate SDI at intervals of 10 and 15 minutes. For well water, filtered water, and clarified lowturbidity(<1.0NTU) water can also be accurately measured.

The calculation formula for EQSDI is as follows:

SDIn=(1-to/tn)×100/n

SDI Pollution Index

(Sample water pressure 30psiThe temperature difference during the testing process shall not exceedUnder the condition of 1 ℃)

N test (membrane filtration sample water) timeGenerally taken as5. 10-15 minutes toAt the beginning of the test(i.e. n=0)time)To obtain a certain volume of sample water through filtration

the time

Tn testing begins nMinutes later(Membrane filtration nth)minute)The time required to filter and obtain the same volume of water sample as mentioned above


2. Technical characteristics

2.1 Host Parameters

1) Power supply: AC 220V

2) Overall power: 30W (max)

3) Operating environment temperature: 5~45 ℃

4) Operating environment humidity: 10~95% RH (none)condensate)

5) Weight:<4Kg

6) Sample conditions: 35 to 100psi, 5-45 ℃minimum flow1000 ml/min

7) External dimensions:host300×300×230mm

8) Connection: Inlet 6.5mm outer diameter polyester pipe outlet DN25

2.2 Technical indicators

1) Measurement range: 0.2~6.67 (SDI15min)

2 )essence indeed degree ±0.2(SDI15min)

3) Pre membrane pressure: 0.207Mpa

4) Display panel: LCDdisplay4 operation and control touch keys

5) Water sample container: 500mL

6) Micro porous filter:φ47mm

7) Filter membrane specification: φ 47mm, pore size 0.45 μ m

8) Protection level: IP58





Small rice mill for laboratory useModel:HAD-NM3

1、 Instrument usage and scope of application

The laboratory small rice mill is a specialized instrument for rice quality testing, mainly used for detecting the whole rice yield and potential rice yield of rice and brown rice. It is widely used in quality inspection agencies at all levels, grain enterprises, agriculture, food processing, and scientific research institutions.

2、 Instrument performance characteristics

The instrument consists of a rice milling system and a bran powder separation system. By adopting technologies such as jet milling, the automatic discharge of polished rice, separation of bran powder, and collection of bran powder can be achieved, greatly improving the surface cleanliness and aesthetics of polished rice grains, and enhancing the sensory inspection of polished rice. The instrument adopts high-precision and high uniformity grinding wheels and discs, which can quickly and efficiently whiten rice, with uniform and consistent results. The rice grains are less broken and the temperature rise is low, which improves the precision rate of rice. The instrument has good stability, low inter table difference, high repeatability, and is closer to the industrial rice milling effect.

3、 Following standards

This instrument complies withGB/T21719-2025The standard requirements.

4、 Main technical indicators

Grinding quantity:10g-20gBrown rice;

Grinding amount approximately16g(Factory standard);

Grinding time:01s-99s

Test scope: Grinding and whitening of round and long grain brown rice.