SmartLineST700 pressure transmitter

NegotiableUpdate on 04/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

STG700 pressure transmitter features: ● Calibration range accuracy up to 0.065% ● Stability: 0.025% full range, maintained for 5 years ● Automatic temperature compensation ● Range ratio of 100:1 ● Fast response time up to 100ms ● Easy to use and intuitive display function ● External zero position, range and configuration function ● Complete self diagnostic function ● Integrated dual sealing design based on ANSI NFPA 70-202 and ANSI SA 12.27.0 to ensure maximum safety ● Standard configuration fully complies with SIL2/3 requirements Range and range limitations: Display header options: Standard LCD display header ● Modular (can be added or removed on site) ● Supports HART protocol ● 0, 90, 180 and 270 degree position adjustment ● Measurement units include: Pa、kPa、MPa、KGcm2、Torr、ATM、i4H2O、mH2O、bar、mbar、inH2O、inHG、FTH2O、mmH2O、mmHG Measurement units such as PSI ● Large screen display (height 9.95mm x width 4.20mm) with 2 lines and 8 characters ● Square root output and write protection prompt ● Display module with internal configuration buttons, which can be used to set and calibrate the transmitter through internal or external buttons

Product Details

STG700 pressure transmitter

STG700 pressure transmitter

characteristic:

The accuracy of the calibration range is as high as 0.065%

Stability: 0.025% full scale, maintained for 5 years

● Automatic temperature compensation

Range ratio 100:1

● Fast response time of up to 100ms

● Easy to use and intuitive display function

● External zero position, range, and configuration functions

● Comprehensive self diagnostic function

● Integrated dual seal design based on ANSI NFPA 70-202 and ANSI SA 12.27.0 to ensure maximum safety

The standard configuration fully complies with SIL2/3 requirements


Range and Range Limitations:

Display header options:

Standard LCD display header

● Modularization (can be added or removed on-site)

● Supports HART protocol

● Position adjustment at 0, 90, 180, and 270 degrees

The measurement units include: Pa、kPa、MPa、KGcm2、Torr、ATM、i4H2O、mH2O、bar、mbar、inH2O、inHG、FTH2O、mmH2O、mmHG Measurement units such as psi

● Large screen display (height 9.95mm x width 4.20mm) 2 lines, 8 characters

Square root output and write protection prompt

The display module is equipped with internal configuration buttons, which can be used to set and calibrate the transmitter through internal or external buttons