Welcome Customer !

Membership

Help

Shenzhen MiEn Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shenzhen MiEn Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 66, Yousong Village, Gongye Road, Longhua Street, Longhua District, Shenzhen City

Contact Now

Skyray HM-5000P portable water quality heavy metal detector

NegotiableUpdate on 05/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Skyray HM-5000P portable water quality heavy metal detector $r $nHM-5000P multifunctional portable heavy metal analyzer is the second generation upgraded product launched by Skyray Instruments. It combines the highly sensitive and institution recognized method of "dissolution voltammetry" with the fast and anti-interference national standard method of "photometric colorimetry". The anodic dissolution method has been listed as a standard testing method by organizations such as the US EPA, such as EPA7063 and 7472; The photometric colorimetric method has been listed as a standard method by multiple countries and widely used.

Product Details

Skyray HM-5000P portable water quality heavy metal detector

Product Description, Technical Parameters, and Configuration

Fast and portable heavy metal analysis instrument

HM-5000PThe multifunctional portable heavy metal analyzer is the second generation upgraded product launched by Tianrui Instrument. Gathers highly sensitive and institution recognized methods——“Dissolution voltammetryAnd fast, anti-interference, national standard methods——“Photometric colorimetric methodAmong them, the anodic dissolution method is used in the United StatesEPAThe institution has listed it as a standard testing method, such asEPA7063and7472Wait; The photometric colorimetric method has been listed as a standard method by multiple countries and widely used.

performance characteristics

1Fast measurement time: detection time less than5Minutes, fast detection time less than30second

2Wide detection range: Typical detection includes heavy metal ions such as copper, cadmium, lead, zinc, mercury, arsenic, manganese, nickel, chromium, iron, cobalt, etc., combined withPCMachine expandable measurement of metal types

3High precision: The detection accuracy can reach1ppbThe detection lower limit is below0.5ppb

4Electrode advantages: Imported working electrodes are used, and the reference electrode adopts a special sintering process. The electrode performance is stable and easy to maintain and replace

5Intelligent operation: Intelligent operation program, guiding customers to easily complete operations

6Diverse testing methods: Users can choose to reuse standard sample measurement records and freely choose between speed and accuracy

7Low usage cost: Low consumable prices and minimal usage

8Safe to use: Non toxic supporting reagents can ensure the safety of personnel use

Advantages of emergency detection

Lightweight and easy to carry

Equipped with specialized field emergency reagent kits that can be directly selected, saving time

The instrument adoptsIP67Dustproof and waterproof grade design can adapt to harsh environments

The LCD screen adopts semi reflective and semi transparent technology, which can display clearly even in outdoor sunlight. The spectral line display function of the instrument facilitates on-site analysis of water sample composition

The instrument is equipped with a large capacity lithium battery to ensure that users can100Continuous measurement for multiple times, sustainable detection10More than hours, with remaining battery indicator function, can be charged using a power adapter or car cigarette lighter for on-board charging

The instrument can be stored2000Group historical measurement data

The instrument supports wireless printing function, on-site printing of historical measurement results (optional Bluetooth printer)

Successfully solved the problem of serious deviation in measurement results caused by mutual interference between copper and zinc when measuring actual water bodies using anodic dissolution method

Incorporating photometric colorimetry, it can effectively replace high organic or complex content in wastewater, preventing interference

application field

Portable application for on-site emergency detection, such as emergency monitoring of water pollution accidents

Laboratory heavy metal detection and analysis

Monitoring of surface water, groundwater, seawater, industrial wastewater, drinking water, or other environmental water bodies

Widely used for detecting heavy metal content in solid substances such as soil and solid waste (through extraction)

Online operation function

containUSBInterface, the instrument can be connected to a computer and coordinated accordinglyPCThe end software implements the following functions:

Configure the built-in instrument15A programmable analysis menu, allowing users to easily configure measurement parameters and methods

It can realize all instrument operations such as hardware detection, electrode maintenance, measurement operation, historical data upload, polarographic analysis, and algorithm application analysis

Software Advantages

Chinese and English interface, friendly and intelligent design, convenient operation

Can be connected to a computer for testing operations, and optimized algorithm integration can further improve measurement accuracy to sub zeroppblevel

Users can use online software to develop more heavy metal detection methods and electrolyte reagents to adapt to a wider range of heavy metal detection and different situations and water conditions

The instrument display screen can directly display spectra and integrates algorithms, ensuring online operation accuracy with a single machine

Instrument configuration

Reagent configuration: Standard configuration includes dissolution voltammetry reagents for copper, cadmium, lead, zinc, mercury, and arsenic, colorimetric reagents for hexavalent chromium, nickel, copper, zinc, and lead, which can meet the requirements100The quantity requirement for sample testing is that users can choose other types of reagents.

Reagent types (standard): Mercury plating solution, reference solution, mercury electrolyte, total arsenic electrolyteCCLZElectrolyteCu/Cd/PbMixed standard solutionHgStandard solutionAsStandard solutionAsAdditivesZnadditive; Chromium colorimetric reagent kit, copper colorimetric reagent kit, nickel colorimetric reagent kit, lead colorimetric reagent kit, zinc colorimetric reagent kit, etc.

Other consumables: analysis cup(1000A)1-5mLpipette1Support and suction head(400A)10-200μLpipette1Support and suction head(10001), electrode cleaning kit1Set.

Electrode group configuration: independent glassy carbon electrode (mercury plating film corresponding to detection items:ZnTheCdThePbTheCuTheMnTheTlEtc.); Independent gold working electrode (corresponding detection item:HgTheAs); Independent platinum counter electrode; Independent Silver/Silver chloride electrode.

Power configuration: power adapter (charger) and cigarette lighter adapter,220Vmains electricity/Ordinary battery/rechargeable battery.

Other configurations: integrated display screen, professional analysis and control software1Set, operation training video CD1Zhang (including user manual), portable carrying case (can be used as a field operation table together with the analysis iron table), analysis iron table bracket1Set, power adapter (charger), rechargeable battery, and cigarette lighter adapter1A colorimetric dish4One, wash the bottle1A wireless Bluetooth printer and a mobile computer that meets customer configuration requirements can be optionally selected.

Detecting instances

containCdThePbTheCuSimultaneous detection of heavy metal elements in artificially synthesized water samples

In this case, a mixed water sample containing several heavy metals was synthesized, each containingCdThePbTheCu, all of which are100ppbCalculate the content of cadmium, lead, and copper in synthetic water samples using a single labeling method

Firstly, scan the blank solution (no peak smoothing is sufficient)

Secondly, scan the standard solution (containingCdThePbTheCueach100ppb)Obtain the peak current values of cadmium, lead, and copper dissolution in the standard solution

Next, scan the synthesized water sample to obtain the peak current values of cadmium, lead, and copper dissolution in the water sample

Then, by calculating the proportional relationship between peak current magnitude and concentration, the respective contents of cadmium, lead, and copper in the water sample were obtained

Skyray HM-5000P portable water quality heavy metal detector