E-mail
yaduxs@126.com
-
Phone
18018578786
-
Address
No. 22, Lane 928, Wenxiang Road, Songjiang District, Shanghai
Shanghai Yadu Electronic Technology Co., Ltd
yaduxs@126.com
18018578786
No. 22, Lane 928, Wenxiang Road, Songjiang District, Shanghai

|
Single phase current voltage power factor table:YK4UIH series Single phase current voltage power factor table
Model and specification: YK4UIH-21 Panel size: 120 × 120mm Hole size: 111 × 111mm Model and specification: YK4UIH-91 Panel size: 96 × 96mm Hole size: 91 × 91mm Model and specification: YK4UIH-31 Panel size: 80 × 80mm Hole size: 76 × 76mm Model and specification: YK4UIH-A1 Panel size: 72 × 72mm Hole size: 67 × 67mm Note: Single phase current voltage power factor meter accuracy: 0.5 level, optional 485 communication, transmission output, input, alarm output, etc Single phase current voltage power factor table |
|
1、 Function of single-phase current voltage power factor meter: The YK4UIH series single-phase current voltage power factor meter mainly measures single-phase current, single-phase voltage, single-phase power factor, etc. CT and PT can be set arbitrarily. Adopting LED digital display, rated current: AC5A AC1A, rated voltage: AC220V. Equipped with high-performance processing chips and independent measurement chips, it has high measurement accuracy and fast operating speed. The single-phase current voltage power factor meter is designed for the power monitoring needs of power systems, industrial and mining enterprises, public facilities, and intelligent buildings. It can measure current, voltage, power factor, and electrical parameters, with switch input and output, power pulse output, and RS485 communication interface. It can achieve remote data transmission and can be equipped with analog output and other functions. Single phase current voltage power factor meters are widely used in energy management systems, substation automation, distribution network automation, residential power monitoring, industrial automation, intelligent buildings, intelligent distribution panels, and switchgear. 1. The display magnification, communication address, baud rate, etc. can be set through the buttons on the panel, making it very flexible and convenient to use. 6. Digital zeroing and tuning, high precision, extremely cost-effective Shanghai Yadu Single phase Current Voltage Power Factor Table IIDigital displayTechnical specifications of single-phase ammeter Single phase current voltage power factor meter accuracy: display accuracy of 0.5 level Single phase current voltage power factor table input: Single phase current voltage power factor meter power supply: Single phase current voltage power factor meter output module: Single phase current voltage power factor table isolation withstand voltage: input and power>2kV, input and output>1kV, power box output>2kV 3、 Schematic diagram for selecting single-phase current voltage power factor table:
3、 Example wiring diagram of single-phase current voltage power factor meter
4、 Precautions for wiring single-phase current voltage power factor meter: 5、 Single phase current voltage power factor table auxiliary power supply: 6: Single phase current voltage power factor meter function module There are two modes to choose from for the switch output: the alarm output mode for the upper and lower limits of the battery. When the measured electrical parameter is below or exceeds the set threshold value, the corresponding output node is turned on. The communication remote control output method (turning off the alarm is the remote control method), the upper computer or background monitoring system directly controls the opening and closing of the output contacts through the 485 communication interface. The switch output interface is a passive normally open contact of the relay, with a contact capacity of AC3A/250V DC3A/30V. 7: Single phase current, voltage, power factor meter, analog transmission output Current output: 0-20mA or 4-20mA |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||