- Phone
-
Address
5th Floor, Dongning Office Building, No. 23 Guangshen Avenue West, Xintang Town, Zengcheng District, Guangzhou City
Guangzhou Hongxi Electronic Technology Co., Ltd
5th Floor, Dongning Office Building, No. 23 Guangshen Avenue West, Xintang Town, Zengcheng District, Guangzhou City
Silver plated Ag/Cu 10um on Calmetrics standard copper substrateThe standard film is used to establish a standard file for the film thickness tester, and is also a standard for verifying and calibrating the accuracy of the test data of the film thickness tester. It belongs to the category of vulnerable and consumable parts, but its service life is closely related to the operating method and storage environment. If operated properly, carefully protected, and stored in a dry and sealed container, its service life can be greatly extended. The film thickness standard sheet is a film thickness tester (X-ray coating thickness gauge) *.
Silver plated Ag/Cu 10um on Calmetrics standard copper substratePhysical picture:


Calmetrics, a company based in the United States, specializes in producing X-ray fluorescence coating film standard parts and element content standard parts, providing calibration services for standard parts. The company has obtained ISO/IEC 17025 certification. The company provides all certificates that comply with NIST (National Institute of Standards and Technology) standards or ANSI (American National Standards Institute) standards. The standard film produced by it has excellent quality, high precision, and good stability.
Calmetrics coating standard sheet is suitable for thickness gauges from various brands such as Fischer Fischer, Korean ISP, Hitachi (including Oxford Instruments (CMI), Seiko) thermoelectric Thermo, Veeco, Micro Pioneer, Shimadzu, Denso, Nayou, Tianrui, Huawei, etc.
The X-ray thickness gauge coating standard sheet is generally divided into single coating sheet, double coating sheet, multi coating sheet, alloy coating sheet, and chemical coating sheet. For example, single coating: Au/xx, double coating: Au/Ni/xx, triple coating: Au/Pd/Ni/xx, alloy coating: Sn Pb/xx, alloy coating: Ni-P/xx.
The coating standard sheet is suitable for X-ray instruments. The majority of thickness standard components for handheld fluorescence meters on the market come from Calmetrics, a company based in the United States.
X-ray standard film, also known as film thickness gauge calibration film or thin film film, is professionally used for instrument standardization calibration and establishment of measurement and analysis files of X-ray thickness gauges (film thickness gauges) when measuring the thickness of metal coatings.
The commonly used specifications for silver plated Ag/Cu 10um on Calmetrics standard copper sheet are as follows: