E-mail
sievers.china@veolia.com
- Phone
-
Address
Building 5-6, Chuangqi Tiandi, 1761 Zhangdong Road, Pudong
Veolia Sievers analyzer
sievers.china@veolia.com
Building 5-6, Chuangqi Tiandi, 1761 Zhangdong Road, Pudong
Sievers Soleil Rapid Microbial DetectorIt is a Rapid Microbial Method (RMM) that can monitor ultra pure levels of microbial load within 45 minutes, ultimately providing the ability to detect microorganisms in near real-time. By utilizing data related to tablet counting, you can make data-driven decisions and take quick action to control pollution throughout the entire production process.
Results can be obtained in less than 45 minutes
• Implement data-driven decision-making and rapid action to control pollution
•SoleilThe combination of reagents and vitality staining agents can detect the live cell count of Gram negative bacteria, Gram positive bacteria, yeast, and mold
High throughput flow cytometry uses proprietary fluorescent staining agents to distinguish between live cells and non biological particles, ensuring accuracy and sensitivity
Not only can it detect water, but it can also detect complex samples, including active pharmaceutical ingredients, culture media, plastics, etc
Better pollution control+increased production flexibility=cost savings
By using the Soleil rapid microbiological detector, production efficiency can be improved without endangering patient safety, while reducing the risk of material or product release. Getting results quickly means making decisions faster, thereby saving costs in many aspects of the production process:
• Pharmaceutical water - key control points
• Cleaning validation/hygiene monitoring
• Process water
• Raw materials
At line monitoring of active pharmaceutical ingredients and intermediate products
Environmental monitoring of process areas
Simple sample preparation
The Soleil system can be used in the laboratory or in the field, and sample preparation is fast and simple. Firstly, heat the sample to 37 ° C in the instrument's constant temperature chamber for a short period of time. Next, add Soleil reagent A, followed by Soleil reagent B. After incubation for 15 minutes, only Soleil reagent C needs to be added.Sievers Soleil Rapid Microbial DetectorThe sample will be analyzed and results will be obtained in 15 minutes or less, depending on the sample size.
Easy microbial monitoring
Soleil's simple setup, software, and consumables make microbial monitoring faster and easier. You can expect to:
The software can guide you through each step of daily startup
Reduce the working time of marking flat plates one by one in the biosafety cabinet (or eliminate the need for this work!)
No need to purchase filters, agar plates, or multiple pipette tips - with Soleil, you only need the recommended pipette tips and bottles
Simplify and high-throughput detection of sample volumes of 20-100 mL