Sievers Eclipse bacterial endotoxin detector

NegotiableUpdate on 01/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The innovative Sievers Eclipse bacterial endotoxin detector can shorten laboratory preparation time by 85%, reduce horseshoe crab reagent usage by 90%, and meet all requirements of the standardized pharmacopoeia: USP, EP 2.6.14, and JP 4.01. Through pioneering technology, the Sievers Eclipse bacterial endotoxin detector significantly reduces pipetting steps, minimizes operator differences, and simplifies assay preparation. Eclipse platform utilizes microfluidic processing and embedding endotoxin for automated automation
Product Details

Breakthrough technology enables automation and compliance

innovativeSievers Eclipse bacterial endotoxin detectorIt can shorten the preparation time for laboratory tests by 85%, reduce the usage of Li Amebocyte Lysate (LAL) by 90%, and meet all the requirements of the standardized pharmacopoeia: USP<85>, EP 2.6.14, and JP 4.01. Through pioneering technology,Sievers Eclipse bacterial endotoxin detectorSignificantly reduced the number of pipetting steps, minimized differences among operators, and simplified laboratory preparation. The Eclipse platform utilizes microfluidic processing and embedded endotoxin for automated dynamic colorimetric assay. The detection capacity of 21 samples on each board does not require complex robot technology, nor does it require the time and technical requirements required for traditional laboratory testing.

Compliant, consistent, and clear bacterial endotoxin testing

Sievers Eclipse bacterial endotoxin detectorAutomated and high-precision BET analysis can be achieved without sacrificing compliance, biochemical reactions, or laboratory footprint. Only 30 pipetting steps are required to use embedded endotoxin standards and positive product control (PPC). Sievers Eclipse microplates can achieve automated operation without the tedious operation or cost of robots.


Characteristics and advantages of Eclipse platform laboratory

  • Only 9 minutes to achieve * compliant 21 sample assay settings

  • Reduce the usage of horseshoe crab reagent by 90%

  • Meets all requirements of the pharmacopoeia: USP

    <85>, EP 2.6.14 and JP 4.01

  • Built in endotoxin for standard curve and positive product control PPC

  • Provide zoning of standard curves, samples, and positive product control PPC

  • Sensitivity as low as 0.005 EU/mL

  • Enterprise software complies with 21 CFR Part 11 and data reliability guidelines

  • Reduce the need for extensive operator training

  • Reduce the risk of repetitive stress injuries

  • Increase daily sample completion volume

  • Use commercially available and FDA approved horseshoe crab reagent LAL

  • Use a cultivation absorbance analyzer to control the reaction temperature at 37+/-1 ℃


Composition of Eclipse Platform

  • Analyzer:Absorbance analyzer, stable cultivation control at 37 ° C, centrifugation technology, and secure data transmission.

  • Microplate:Liquid processing equipment, this technology achieves automation through innovative microfluidic technology with embedded endotoxin standards and positive product control (PPC).

  • Software:Highly customizable enterprise solutions that comply with 21CFR Part 11 and ALCOA+data integrity.

Eclipse microplate is used in conjunction with Eclipse analyzer and software to measure and evenly distribute reagent water, sample, and horseshoe crab reagent LAL in a 104 optical cell using centrifugal force and pneumatic chamber. The optical cell includes partitions for standard curves, samples, and positive product control PPC. Control the reaction at 37+/-1 ° C and obtain a high-definition view of each cell by obtaining a reading of 405 nm every five seconds.

Eclipse specifications

System specifications

Bacterial endotoxin detection method Dynamic color rendering
Detection Mode absorbance
scope 0.005-50 EU/mL
Jingque degree ≤ 15% CV onset time
accuracy 50-200% of the true value
Sample Type Water solution, injected with a pipette
calibration Long for 12 months
analysis time Two more hours
Sample temperature 37 ± 1 °C
ambient temperature 17- 30 °C
capacity 21 additional samples, in duplicate, including positive product control
temperature control 37 ± 0.5 °C
light source LED emitter
Fluid fault detection 1450 nm emitter
Optical accuracy ≤ 5% deviation from expected value
Optical linearity R ≥ 0.980
Optical wavelength filter 405 nm
Read interval 5 seconds

Analyzer specifications

output USB data output
display OLED
Power requirements 100-240 Volts AC @40/60 Hz
fuse

T8 A 250 VAC fuse, size 5 x20 millimeters. Only Littlfuse218008 or Cooper Bussmann S 506-8-R.

size Height: 17.5 cm (6.9 in), Width: 35.1 cm (13.8 in), Depth: 50.3 cm (19.8 in)
weight 10 kg (22.1 lbs)
Safety Certification UL 61010-1:2012Ed.3+R:20Apr2016, CSA C22.2#61010-2-020, CSA C22.2#61010-1-12:2012Ed.3+U1; U2, IEC 61010-1:2010 Ed.3+C1; C2, UL 61010-2-010:2015Ed.3, IEC 61010-2-010:2003Ed.2, UL 61010-2-020:2016Ed.3, IEC 61010-2-020:2016Ed.3, CSA C22.2#61010-2-010:2015Ed.3

environment

High relative humidity 85%, no condensation
High altitude 3,000 m(9.800 ft)
pollution level 2