⊙ Overview: The core part of the outdoor temperature and humidity sensor consists of a set of highly integrated temperature and humidity sensor chips, all of which are fully calibrated digital output chips

Product Details

⊙ Overview
The core part of the outdoor temperature and humidity sensor consists of a set of highly integrated temperature and humidity sensor chips, all of which are fully calibrated digital output chips. Lightweight louver boxes can prevent direct radiation from the sun and reflected radiation from the ground, protecting the internal instruments from strong winds, rain, snow, and other factors. And its special surface treatment and structural design enable the sensing part of the instrument to be appropriately ventilated, truly sensing changes in environmental factors such as external air temperature and humidity, carbon dioxide, etc.
This product adopts CMOSens patented technology to ensure high reliability and excellent long-term stability. The sensor includes a capacitive polymer humidity sensitive element and a temperature sensitive element made of bandgap material, which are designed on the same chip as a 14 bit A/D converter and a serial interface circuit.
This sensor has excellent quality, ultra fast response, strong anti-interference ability, and high cost-effectiveness. Each sensor chip is calibrated in an extremely precise constant temperature chamber, using a mirror condensation dew point meter as a reference. The calibration coefficients obtained through calibration are stored in the OTP memory of the chip itself in program form. By using a two-wire serial interface and internal voltage adjustment, peripheral system integration becomes fast and simple.
⊙ Scope of application
This is widely used for measuring temperature and humidity in agriculture, forestry, meteorological environment, storage, greenhouse, environmental protection, meteorological stations, ships, docks, and other fields.
⊙ Technical parameters
Power supply: 12-24V DC
Signal output: voltage 0.4-2V, current 4-20mA, RS485
Power consumption: 5ma

current mode

temperature

4~20mA

correspond to

-40~60℃

Accuracy: ± 0.2 ℃

Voltage type

temperature

0.4~2V

current mode

humidity

4~20mA

correspond to

0~***

Accuracy: ± 3%

Voltage type

humidity

0.4~2V

Communication method: 485 communication, transmission distance<1000 meters
Communication speed: 9600, n,8,1
Communication protocol: MODBUS protocol
⊙ Functional Features
Small size, light weight, easy installation
High measurement accuracy, reliable performance, ensuring normal operation.
Strong anti-interference ability
Long service life
Fast response speed and high data transmission efficiency.
⊙ Definition of Line Color

line color

red

Huang

blue

Green/Black

definition

positive power terminal

temperature

485A

humidity

485B

negative

⊙ Calculation formula
Voltage type: Air temperature=Output voltage/2 * 100-40
Voltage type: Air humidity=output voltage/2 * 100
Current type: Air temperature=(output current -4)/16 * 100-40
Current type: Air humidity=(output current -4)/16 * 100
⊙ MODBUS protocol (00 is the broadcast address)
1. Data transmission method: baud rate of 9600bps
8 data bits, 1 stop bit, no checksum.
Command example:
All register address bytes, register digit sections, and data bytes in the command are placed first and last, respectively; The low byte of the CRC check code comes first, followed by the high byte; Read temperature and humidity values:
Sent: 02 03 00 00 02 C4 38 (8 bytes)

From device address

function code

Starting register address

number of registers

CRC-L

CRC-H

0x02

0x03

0x00

0x00

0x00

0x02

0xC4

0x38

Response: 02 03 04 02 75 00 C0 D9 01 (9 bytes)

From device address

function code

Number of bytes in the data area

register

Data (temperature)

register

Data (humidity)

CRC

-L

CRC

-H

0x02

0x03

0x04

0x02

0x75

0x00

0xC0

0xD9

0x01

(Temperature value=Temperature return value/10-40, Temperature return value=0x0275)
(Humidity value=Humidity return value/10, Humidity return value=0xC0)
D9 01: CRC verification value.
Modify device address: (Address changed to 03)
Send: 00 10 00 00 01 02 03 FA 00 (11 bytes)

Device address

1 byte

0x00

function number

1 byte

0x10

Starting register address

2 bytes

0x1000

number of registers

2 bytes

0x0001

Effective byte count

1 byte

0x02

Write device address

2 bytes

0x0003

verify

2 bytes

0 xfa 00

Response: 00 10 00 00 01 04 D8 (8 bytes)

Device address

1 byte

0x00

function number

1 byte

0x10

Starting register address

2 bytes

0x1000

number of registers

2 bytes

0x0001

verify

2 bytes

0x04D8

⊙ Maintenance and upkeep
This instrument is a precision electronic product, and proper maintenance and upkeep can help protect its performance and extend its service life.