Welcome Customer !

Membership

Help

Taizhou Shuanghua Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Taizhou Shuanghua Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Hailing District Industrial Park, Taizhou City, Jiangsu Province

Contact Now

Shuanghua S-type WRP platinum rhodium thermocouple

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The shortcomings of the Shuanghua S-type WRP platinum rhodium thermocouple are its thermoelectric potential, low thermoelectric potential, low sensitivity, decreased mechanical strength at high temperatures, high sensitivity to pollution, and expensive precious metal materials, resulting in a large one-time investment. The S-type thermocouple, also known as the single platinum rhodium thermocouple, has an S division mark and is mainly used to measure the temperature of the medium between 0 and 1600 ℃. It is a category of precious metal thermocouples. Normal use in high-temperature environments such as coking plants and steel mills. The long-term high operating temperature of the nWRP-131 S-type platinum rhodium thermocouple is 1300 ℃, and the short-term high operating temperature is 1600 ℃

Product Details

Shuanghua S-type WRP platinum rhodium thermocoupleIn the thermocouple series, it has the advantages of high accuracy, good stability, wide temperature measurement range, and long service life. Because platinum rhodium and platinum rhodium alloys are made of thermocouple wire, they are called platinum rhodium thermocouples, which are divided intoplatinum-rhodium10-Platinum thermocouple(SType thermocouple)Theplatinum-rhodium13-Platinum(RType thermocouple)Platinum rhodium30-platinum-rhodium6Thermocouple(BType thermocouple).Suitable for high-temperature applications in various production processes, widely used for temperature measurement in industrial operations such as powder metallurgy, sintering bright furnaces, vacuum furnaces, smelting furnaces, glass, steelmaking furnaces, environmental power generation, thermal power plants, ceramic processing, and salt bath furnaces.

【 Detailed Introduction 】

WRP-SPlatinum rhodium thermocouple

platinum-rhodium10-Platinum thermocouple(SType thermocouple)For precious metal thermocouples. Its positive and(SP)The nominal chemical composition of the alloy is platinum rhodium alloy, with positive and rhodium containing elements10%, containing platinum90%, negative and(SN)For pure platinum, it is commonly known as a single platinum rhodium thermocouple. The long-term upper limit operating temperature of this thermocouple is1300The short-term upper limit usage temperature is1600.

SType thermocoupleIn the thermocouple series, it has the advantages of high accuracy, good stability, wide temperature measurement range, and long service life. It has good physical and chemical properties, stable thermoelectric potential, and excellent oxidation resistance at high temperatures, making it suitable for both oxidizing and inert atmospheres. Due toSPlatinum rhodium thermocoupleHas excellent comprehensive performance and conforms to the international temperature scale for useSHigh temperature resistant thermocoupleFor a long time, it has been used as an interpolation instrument for international temperature scales.

SThe shortcomings of thermocouples are thermoelectric potential, low thermoelectric potential, low sensitivity, decreased mechanical strength at high temperatures, high sensitivity to pollution, expensive precious metal materials, and therefore a large one-time investment.

WRQ-RPlatinum rhodium thermocouple

platinum-rhodium13-platinumthermocoupleRType thermocouple)For precious metal thermocouples. The diameter of the filament is specified as0.5mm, allowable deviation-0.015mm, its correctness and(RP)The nominal chemical composition is platinum rhodium alloy, which contains rhodium13%, containing platinum87%, negative and(RN)For pure platinum, the long-term upper limit usage temperature is1300℃, the short-term upper limit usage temperature is1600℃。

RType thermocoupleIn the thermocouple series, it has the advantages of high accuracy, good stability, wide temperature measurement range, and long service life. It has good physical and chemical properties, stable thermoelectric potential, and excellent oxidation resistance at high temperatures, making it suitable for both oxidizing and inert atmospheres. Due toRPlatinum rhodium thermocoupleThe comprehensive performance andSThermocouples of the same type have been difficult to promote in China, and are rarely used for temperature measurement in China, except for their application in imported equipment.1967Year to Year1971During the year, the United KingdomNPL, United StatesNBSAnd CanadaNRCThree major research institutions conducted a collaborative study, and the results showed that,RType thermocoupleStability and reproducibility ratioSThe thermocouples are all good, but research in this area has not yet been conducted in China.

RThe shortcomings of thermocouples are thermoelectric potential, low thermoelectric potential rate, low sensitivity reading, decreased mechanical strength at high temperatures, high sensitivity to pollution, expensive precious metal materials, and therefore a large one-time investment.

WRR-BPlatinum rhodium thermocouple

platinum-rhodium30-platinum-rhodium6Thermocouple(BType thermocouple)For precious metal thermocouples. allowable deviation-0.015mm, its correctness and(BP)The nominal chemical composition is platinum rhodium alloy, which contains rhodium30%, containing platinum70%, negative and(BN)Platinum rhodium alloy, with rhodium content6%, therefore commonly known asDouble platinum rhodium thermocoupleThe upper limit temperature for long-term use of this thermocouple is1600℃, the upper limit temperature for short-term use is1800℃。BType thermocoupleIn the thermocouple series, it has the advantages of high accuracy, stability, wide temperature measurement range, long service life, and high temperature measurement upper limit. Suitable for oxidizing and inert atmospheres, and can also be used in vacuum for a short period of time, but not suitable for reducing atmospheres or atmospheres containing metal or non-metal vapors.BPlatinum rhodium thermocoupleOne obvious advantage is that there is no need to use compensating wires for compensation, because in0~50The thermoelectric potential within the temperature range is less than3μV.BThe shortcomings of thermocouples are thermoelectric potential, low thermoelectric potential, low sensitivity, decreased mechanical strength at high temperatures, high sensitivity to pollution, expensive precious metal materials, and therefore a large one-time investment.

Shuanghua S-type WRP platinum rhodium thermocoupleThe thermoelectric heating will increase as the temperature at the measuring end rises, and its size is only related to the thermocouple material and the temperature at both ends, and is independent of the length and diameter of the thermocouple. The appearance of various platinum rhodium thermocouples often varies due to needs, but their basic structures are roughly the same, usually consisting of thermoelectric, protective tubes, and junction boxes as the main components.

Application of Platinum Rhodium Thermocouples

Widely used for temperature measurement in industrial operations such as powder metallurgy, sintering bright furnaces, vacuum furnaces, smelting furnaces, glass, steelmaking furnaces, environmentally friendly power generation, thermal power plants, ceramic processing, and salt bath furnaces.Shuanghua S-type WRP platinum rhodium thermocoupleMeasure temperature and tolerance

Thermocouple category

code name

graduation mark

temperature range

measure temperature

allowable deviationt

platinum-rhodium30-platinum-rhodium6

WRR

B

0~1800

0-1600

±1.5or±0.25%t

platinum-rhodium10-platinum

WRP

S

0~1600

0-1300

±1.5or±0.25%t

platinum-rhodium13-platinum

WRQ

R

0~1600

0-1300

±1.5or±0.25%t

Platinum rhodium thermocouple model and specifications

Typenumber

graduation mark

Temperature measurement range

Protective tube material

Thermal response time

Specificationsmm

diameterd

Chief of Staffxdeep insertionLxl

WRP-130

WRP2-130

S

0-1600

corundum tube

150S

Φ16

300x150
350x200
400x250
450x300
550x400
650x500
900x750
1150x1000

1650x1500

2150x2000

Sizes can be customized

WRP-131

WRP2-131

Double layer corundum tube

360S

Φ25

WRQ-130

WRQ2-130

R

0-1600

corundum tube

150S

Φ16

WRQ-131

WRQ2-131

Double layer corundum tube

360S

Φ25

WRR-130

WRR2-130

B

0-1800

corundum tube

150S

Φ16

WRR-131

WRR2-131

Double layer corundum tube

360S

Φ25

1.Indicate the thermocouple model or scale number, and the temperature range for use.
2.The diameter, length (total length and insertion depth), and material (corundum ceramic or stainless steel) of the thermocouple protection tube.
3.The fixed method (fixed or movable thread, fixed or movable flange) requires corresponding dimensions to be provided.

4.Our company produces measurement related products such as thermocouples, thermistors, steel thermometers, temperature measuring instruments, compensation wires, etc. of various models and division numbers.