Overview

DC high current generator is suitable for current load testing and temperature rise testing of bus ducts, switchgear, circuit breakers, contactors, current transformers, and other electrical equipment. Suitable units: power plants, distribution stations, electrical manufacturing plants and research institutions, laboratories, etc.

Product Details

Short circuit current withstand test device Short circuit current withstand test machine Short circuit current withstand machine


4: Instructions for use

1First, connect the devices to both phasesAC380VPower supply, power capacity should meet the requirements80KA(Short term)

2It is best to use the power cord input35mm² cable, and the distance from the power switch is not greater than10m

3Ensure proper grounding and other protective measures for the equipment

4Connect the test sample and confirm its reliability, output line≥500mm², Length ≤2mm

5Turn on the device power

6Click the settings button to enter the settings interface, set the target current value and working time, and return to the testing interface

7clickStart up/Stop "button, the device starts to store energy and boost voltage, displaying output voltage and output current. When the target value is reached, the device emits a" beep "sound

8When presetting, if you need to output the current size, you can fine tune itUp flow or Down flow button

9issueAfter the beep sound, click the "Current Test" button to complete the vacuum contactor suction set time test. At the same time, the oscilloscope records the output current and time

5: Precautions

1The equipment should be kept well ventilated, and the surrounding area should be free of flammable and explosive gases and dust during testing to prevent accidents caused by sparks due to poor contact caused by high current!

2It is best to have two staff members present during the experiment, and other idle personnel should leave

3Before the experiment, it is necessary to connect the safety protection devices of the equipment, including isolation belts, test warning signs, etc.

6: Random attachments

1The10KAOne complete set of equipment

2Power input cable25mm²*10ma

3High current output line250mm²*1mTwo roots

4User Manual a copy

5Product Warranty Card a copy

Can be customized according to user needs!